These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

90 related articles for article (PubMed ID: 16241626)

  • 1. 10-Hz grazing--incidence pumped Ni-like Mo x-ray laser.
    Tümmler J; Janulewicz KA; Priebe G; Nickles PV
    Phys Rev E Stat Nonlin Soft Matter Phys; 2005 Sep; 72(3 Pt 2):037401. PubMed ID: 16241626
    [TBL] [Abstract][Full Text] [Related]  

  • 2. High-repetition-rate grazing-incidence pumped x-ray laser operating at 18.9 nm.
    Keenan R; Dunn J; Patel PK; Price DF; Smith RF; Shlyaptsev VN
    Phys Rev Lett; 2005 Mar; 94(10):103901. PubMed ID: 15783486
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Thin film beam splitter multiple short pulse generation for enhanced Ni-like Ag x-ray laser emission.
    Cojocaru GV; Ungureanu RG; Banici RA; Ursescu D; Delmas O; Pittman M; Guilbaud O; Kazamias S; Cassou K; Demailly J; Neveu O; Baynard E; Ros D
    Opt Lett; 2014 Apr; 39(8):2246-9. PubMed ID: 24978964
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Optimization of a tabletop high-repetition-rate soft x-ray laser pumped in double-pulse single-beam grazing incidence.
    Zimmer D; Zielbauer B; Pittman M; Guilbaud O; Habib J; Kazamias S; Ros D; Bagnoud V; Kuehl T
    Opt Lett; 2010 Feb; 35(4):450-2. PubMed ID: 20160780
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Demonstration of a 100 Hz repetition rate gain-saturated diode-pumped table-top soft x-ray laser.
    Reagan BA; Wernsing KA; Curtis AH; Furch FJ; Luther BM; Patel D; Menoni CS; Rocca JJ
    Opt Lett; 2012 Sep; 37(17):3624-6. PubMed ID: 22940970
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Quantitative study of 10 Hz operation of a soft x-ray laser-energy stability and target considerations.
    Lindau F; Lundh O; Persson A; Cassou K; Kazamias S; Ros D; Plé F; Jamelot G; Klisnick A; de Rossi S; Joyeux D; Zielbauer B; Ursescu D; Kühl T; Wahlström CG
    Opt Express; 2007 Jul; 15(15):9486-93. PubMed ID: 19547296
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Optimization toward a high-average-brightness soft-x-ray laser pumped at grazing incidence.
    Cassou K; Kazamias S; Ros D; Plé F; Jamelot G; Klisnick A; Lundh O; Lindau F; Persson A; Wahlström CG; de Rossi S; Joyeux D; Zielbauer B; Ursescu D; Kühl T
    Opt Lett; 2007 Jan; 32(2):139-41. PubMed ID: 17186043
    [TBL] [Abstract][Full Text] [Related]  

  • 8. High-energy 13.9 nm table-top soft-x-ray laser at 2.5 Hz repetition rate excited by a slab-pumped Ti:sapphire laser.
    Martz DH; Alessi D; Luther BM; Wang Y; Kemp D; Berrill M; Rocca JJ
    Opt Lett; 2010 May; 35(10):1632-4. PubMed ID: 20479832
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Role of the precursor in a triple-pulse pumping scheme of a nickel-like silver soft-x-ray laser in the grazing-incidence-pumping geometry.
    Janulewicz KA; Kim CM
    Phys Rev E Stat Nonlin Soft Matter Phys; 2010 Nov; 82(5 Pt 2):056405. PubMed ID: 21230600
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Optimal main pulse angle for different preplasma conditions in transient collisionally pumped x-ray lasers.
    Ursescu D; Zielbauer B; Kuehl T; Neumayer P; Pert G
    Phys Rev E Stat Nonlin Soft Matter Phys; 2007 Apr; 75(4 Pt 2):045401. PubMed ID: 17500953
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Hour-long continuous operation of a tabletop soft x-ray laser at 50-100 Hz repetition rate.
    Reagan BA; Li W; Urbanski L; Wernsing KA; Salsbury C; Baumgarten C; Marconi MC; Menoni CS; Rocca JJ
    Opt Express; 2013 Nov; 21(23):28380-6. PubMed ID: 24514347
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Demonstration of an all-diode-pumped soft x-ray laser.
    Furch FJ; Reagan BA; Luther BM; Curtis AH; Meehan SP; Rocca JJ
    Opt Lett; 2009 Nov; 34(21):3352-4. PubMed ID: 19881591
    [TBL] [Abstract][Full Text] [Related]  

  • 13. High-energy directly diode-pumped Q-switched 1617 nm Er:YAG laser at room temperature.
    Wang M; Zhu L; Chen W; Fan D
    Opt Lett; 2012 Sep; 37(17):3732-4. PubMed ID: 22941006
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Pump energy reduction for a high gain Ag X-ray laser using one long and two short pump pulses.
    Banici RA; Cojocaru GV; Ungureanu RG; Dabu R; Ursescu D; Stiel H
    Opt Lett; 2012 Dec; 37(24):5130-2. PubMed ID: 23258028
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Valley density profile for highly efficient x-ray lasers with good beam quality.
    Zhao J; Dong QL; Zhang J
    Opt Lett; 2007 Mar; 32(5):491-3. PubMed ID: 17392898
    [TBL] [Abstract][Full Text] [Related]  

  • 16. High efficiency, linearly polarized, directly diode-pumped Er:YAG laser at 1617  nm.
    Yu Z; Wang M; Hou X; Chen W
    Appl Opt; 2014 Dec; 53(34):8032-5. PubMed ID: 25607959
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Preplasma conditions for operation of 10-Hz subjoule femtosecond-laser-pumped nickel-likex-ray lasers.
    Tommasini R; Eidmann K; Kawachi T; Fill EE
    Phys Rev E Stat Nonlin Soft Matter Phys; 2004 Jun; 69(6 Pt 2):066404. PubMed ID: 15244742
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Pulse duration measurements of grazing-incidence-pumped high repetition rate Ni-like Ag and Cd transient soft x-ray lasers.
    Larotonda MA; Wang Y; Berrill M; Luther BM; Rocca JJ; Shakya MM; Gilbertson S; Chang Z
    Opt Lett; 2006 Oct; 31(20):3043-5. PubMed ID: 17001394
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Study of soft X-ray radiation in 8-20 nm region from a laser plasma source].
    Guo Y
    Guang Pu Xue Yu Guang Pu Fen Xi; 1998 Jun; 18(3):265-8. PubMed ID: 15810265
    [TBL] [Abstract][Full Text] [Related]  

  • 20. In-band pumped polarized, narrow-linewidth Er:YAG laser at 1645 nm.
    Wang M; Meng J; Hou X; Chen W
    Appl Opt; 2014 Oct; 53(30):7153-6. PubMed ID: 25402806
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.