These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
7. Continuous cell washing and mixing driven by an ultrasound standing wave within a microfluidic channel. Hawkes JJ; Barber RW; Emerson DR; Coakley WT Lab Chip; 2004 Oct; 4(5):446-52. PubMed ID: 15472728 [TBL] [Abstract][Full Text] [Related]
8. A QCM immunosensor for Salmonella detection with simultaneous measurements of resonant frequency and motional resistance. Su XL; Li Y Biosens Bioelectron; 2005 Dec; 21(6):840-8. PubMed ID: 16257651 [TBL] [Abstract][Full Text] [Related]
9. Detection of pathogen Escherichia coli O157:H7 AT 70 cells/mL using antibody-immobilized biconical tapered fiber sensors. Rijal K; Leung A; Shankar PM; Mutharasan R Biosens Bioelectron; 2005 Dec; 21(6):871-80. PubMed ID: 16257655 [TBL] [Abstract][Full Text] [Related]
10. Bacillus globigii bugbeads: a model simulant of a bacterial spore. Farrell S; Halsall HB; Heineman WR Anal Chem; 2005 Jan; 77(2):549-55. PubMed ID: 15649052 [TBL] [Abstract][Full Text] [Related]
11. Detection of pathogenic bacteria in food samples using highly-dispersed carbon particles. Chemburu S; Wilkins E; Abdel-Hamid I Biosens Bioelectron; 2005 Sep; 21(3):491-9. PubMed ID: 16076439 [TBL] [Abstract][Full Text] [Related]
12. Detection of Escherichia coli O157:H7 with langasite pure shear horizontal surface acoustic wave sensors. Berkenpas E; Millard P; Pereira da Cunha M Biosens Bioelectron; 2006 Jun; 21(12):2255-62. PubMed ID: 16356708 [TBL] [Abstract][Full Text] [Related]
13. Accumulation of E. Coli bacteria in mini-channel flow. Mayeed MS; Mian A; Auner GW; Newaz GM J Biomech Eng; 2006 Jun; 128(3):458-61. PubMed ID: 16706596 [TBL] [Abstract][Full Text] [Related]
14. Optical leaky waveguide sensor for detection of bacteria with ultrasound attractor force. Zourob M; Hawkes JJ; Coakley WT; Treves Brown BJ; Fielden PR; McDonnell MB; Goddard NJ Anal Chem; 2005 Oct; 77(19):6163-8. PubMed ID: 16194074 [TBL] [Abstract][Full Text] [Related]
15. Improvement of immunodetection of bacterial spore antigen by ultrasonic cavitation. Borthwick KA; Love TE; McDonnell MB; Coakley WT Anal Chem; 2005 Nov; 77(22):7242-5. PubMed ID: 16285671 [TBL] [Abstract][Full Text] [Related]
16. Sequential detection of Salmonella typhimurium and Bacillus anthracis spores using magnetoelastic biosensors. Huang S; Yang H; Lakshmanan RS; Johnson ML; Wan J; Chen IH; Wikle HC; Petrenko VA; Barbaree JM; Chin BA Biosens Bioelectron; 2009 Feb; 24(6):1730-6. PubMed ID: 18954970 [TBL] [Abstract][Full Text] [Related]
17. Deposition of Bacillus subtilis spores using an airbrush-spray or spots to study surface decontamination by pulsed light. Levy C; Bornard I; Carlin F J Microbiol Methods; 2011 Feb; 84(2):223-7. PubMed ID: 21129416 [TBL] [Abstract][Full Text] [Related]
18. Ultrasonic manipulation of particles and cells. Ultrasonic separation of cells. Coakley WT; Whitworth G; Grundy MA; Gould RK; Allman R Bioseparation; 1994 Apr; 4(2):73-83. PubMed ID: 7765041 [TBL] [Abstract][Full Text] [Related]
19. Surface acoustic wave concentration of particle and bioparticle suspensions. Li H; Friend JR; Yeo LY Biomed Microdevices; 2007 Oct; 9(5):647-56. PubMed ID: 17530412 [TBL] [Abstract][Full Text] [Related]
20. High throughput particle analysis: combining dielectrophoretic particle focussing with confocal optical detection. Holmes D; Morgan H; Green NG Biosens Bioelectron; 2006 Feb; 21(8):1621-30. PubMed ID: 16332434 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]