138 related articles for article (PubMed ID: 16244025)
1. An in vitro comparison of the electrical conducting properties of multiport versus single-port epidural catheters for the epidural stimulation test.
Tsui BCH; Sze CKC
Anesth Analg; 2005 Nov; 101(5):1528-1530. PubMed ID: 16244025
[TBL] [Abstract][Full Text] [Related]
2. The electrical properties of epidural catheters: what are the requirements for nerve stimulation guidance?
Tamai H; Sawamura S; Atarashi H; Takeda K; Ohe K; Hanaoka K
Anesth Analg; 2005 Jun; 100(6):1704-1707. PubMed ID: 15920199
[TBL] [Abstract][Full Text] [Related]
3. Thoracic epidural catheters via the caudal and lumbar approaches using styletted multiple port catheters in pediatric patients: a report of three cases.
Tsui BC; Usher A; Kulkarni PR; Scott SL
Acta Anaesthesiol Scand; 2006 Apr; 50(4):514-7. PubMed ID: 16548868
[TBL] [Abstract][Full Text] [Related]
4. Response Patterns to the Electric Stimulation of Epidural Catheters in Pregnant Women: A Randomized Controlled Trial of Uniport Versus Multiport Catheters.
Patel R; Arzola C; Petrounevitch V; Balki M; Downey K; Tsui BC; Carvalho JC
Anesth Analg; 2016 Oct; 123(4):950-4. PubMed ID: 27111644
[TBL] [Abstract][Full Text] [Related]
5. A comparison of multiport and uniport epidural catheters in laboring patients.
D'Angelo R; Foss ML; Livesay CH
Anesth Analg; 1997 Jun; 84(6):1276-9. PubMed ID: 9174306
[TBL] [Abstract][Full Text] [Related]
6. Comparison of Changes in Tensile Strength in Three Different Flexible Epidural Catheters Under Various Conditions.
Gonzalez Fiol A; Horvath R; Schoenberg C; Ahmed N; Dhar SK; Le V
Anesth Analg; 2016 Jul; 123(1):233-7. PubMed ID: 27111646
[TBL] [Abstract][Full Text] [Related]
7. Tensile strength of 19- and 20-gauge arrow epidural catheters.
Tsui BCH; Finucane B
Anesth Analg; 2003 Nov; 97(5):1524-1526. PubMed ID: 14570679
[TBL] [Abstract][Full Text] [Related]
8. Confirmation of epidural catheter placement using nerve stimulation.
Tsui BC; Gupta S; Finucane B
Can J Anaesth; 1998 Jul; 45(7):640-4. PubMed ID: 9717595
[TBL] [Abstract][Full Text] [Related]
9. Response to: Response Patterns to the Electric Stimulation of Epidural Catheters in Pregnant Women: A Randomized Controlled Trial of Uniport Versus Multiport Catheters.
Muggleton E; Muggleton T
Anesth Analg; 2017 Mar; 124(3):1010. PubMed ID: 28207450
[No Abstract] [Full Text] [Related]
10. Determining epidural catheter location using nerve stimulation with radiological confirmation.
Tsui BC; Guenther C; Emery D; Finucane B
Reg Anesth Pain Med; 2000; 25(3):306-9. PubMed ID: 10834789
[TBL] [Abstract][Full Text] [Related]
11. Minimum current requirements for epidural stimulation test confirmation of epidural and intrathecal catheter placement.
Sutherland MA; Viscomi CM; Dominick TS; Anderson EL
Reg Anesth Pain Med; 2009; 34(6):575-7. PubMed ID: 19916250
[TBL] [Abstract][Full Text] [Related]
12. Thoracic caudal epidural catheter localization using ultrasound guidance.
Bachman SA; Taenzer AH
Paediatr Anaesth; 2020 Feb; 30(2):194-195. PubMed ID: 31863518
[TBL] [Abstract][Full Text] [Related]
13. [Usefulness of epidural nerve stimulation to confirm epidural catheter placement].
Ozawa T; Kaneko H; Nomura T; Asano M
Masui; 2002 Apr; 51(4):400-4. PubMed ID: 11995348
[TBL] [Abstract][Full Text] [Related]
14. Confirmation of direct epidural catheter placement using nerve stimulation in pediatric anesthesia.
Goobie SM; Montgomery CJ; Basu R; McFadzean J; O'Connor GJ; Poskitt K; Tsui BCH
Anesth Analg; 2003 Oct; 97(4):984-988. PubMed ID: 14500145
[TBL] [Abstract][Full Text] [Related]
15. Determination of epidural catheter placement using nerve stimulation in obstetric patients.
Tsui BC; Gupta S; Finucane B
Reg Anesth Pain Med; 1999; 24(1):17-23. PubMed ID: 9952090
[TBL] [Abstract][Full Text] [Related]
16. Threshold current for an insulated epidural needle in pediatric patients.
Tsui BCH; Wagner A; Cave D; Seal R
Anesth Analg; 2004 Sep; 99(3):694-696. PubMed ID: 15333396
[TBL] [Abstract][Full Text] [Related]
17. Electrical stimulation of the epidural space using a catheter with a removable stylet.
Charghi R; Chan SY; Kardash KJ; Finlayson RJ; Tran DQ
Reg Anesth Pain Med; 2007; 32(2):152-6. PubMed ID: 17350527
[TBL] [Abstract][Full Text] [Related]
18. Evaluation of epidural and peripheral nerve catheter heating during magnetic resonance imaging.
Owens S; Erturk MA; Ouanes JP; Murphy JD; Wu CL; Bottomley PA
Reg Anesth Pain Med; 2014; 39(6):534-9. PubMed ID: 25275576
[TBL] [Abstract][Full Text] [Related]
19. Uniport soft-tip, open-ended catheters versus multiport firm-tipped close-ended catheters for epidural labor analgesia: a quality assurance study.
Jaime F; Mandell GL; Vallejo MC; Ramanathan S
J Clin Anesth; 2000 Mar; 12(2):89-93. PubMed ID: 10818320
[TBL] [Abstract][Full Text] [Related]
20. Multiport epidural catheters: does the air test work?
Leighton BL; Topkis WG; Gross JB; Arkoosh VA; Lee SH; Huffnagle HJ; Huffnagle SL
Anesthesiology; 2000 Jun; 92(6):1617-20. PubMed ID: 10839910
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]