187 related articles for article (PubMed ID: 16245601)
1. A new imaging strategy using wideband transient response of ultrasound contrast agents.
Kruse DE; Ferrara KW
IEEE Trans Ultrason Ferroelectr Freq Control; 2005 Aug; 52(8):1320-9. PubMed ID: 16245601
[TBL] [Abstract][Full Text] [Related]
2. Acoustic response of compliable microvessels containing ultrasound contrast agents.
Qin S; Ferrara KW
Phys Med Biol; 2006 Oct; 51(20):5065-88. PubMed ID: 17019026
[TBL] [Abstract][Full Text] [Related]
3. Selective imaging of adherent targeted ultrasound contrast agents.
Zhao S; Kruse DE; Ferrara KW; Dayton PA
Phys Med Biol; 2007 Apr; 52(8):2055-72. PubMed ID: 17404455
[TBL] [Abstract][Full Text] [Related]
4. Harmonic vibro-acoustography.
Chen S; Kinnick RR; Greenleaf JF; Fatemi M
IEEE Trans Ultrason Ferroelectr Freq Control; 2007 Jul; 54(7):1346-51. PubMed ID: 17718323
[TBL] [Abstract][Full Text] [Related]
5. Optimisation of the transmit beam parameters for generation of subharmonic signals in native and altered populations of a commercial microbubble contrast agent SonoVue®.
Ivory AM; Meaney JF; Fagan AJ; Browne JE
Phys Med; 2020 Feb; 70():176-183. PubMed ID: 32036334
[TBL] [Abstract][Full Text] [Related]
6. A sensitive TLRH targeted imaging technique for ultrasonic molecular imaging.
Hu X; Zheng H; Kruse DE; Sutcliffe P; Stephens DN; Ferrara KW
IEEE Trans Ultrason Ferroelectr Freq Control; 2010; 57(2):305-16. PubMed ID: 20178897
[TBL] [Abstract][Full Text] [Related]
7. Phase-dependent dual-frequency contrast imaging at sub-harmonic frequency.
Shen CC; Cheng CH; Yeh CK
IEEE Trans Ultrason Ferroelectr Freq Control; 2011 Feb; 58(2):379-88. PubMed ID: 21342823
[TBL] [Abstract][Full Text] [Related]
8. Dual high-frequency difference excitation for contrast detection.
Yeh CK; Su SY; Shen CC; Li ML
IEEE Trans Ultrason Ferroelectr Freq Control; 2008 Oct; 55(10):2164-76. PubMed ID: 18986865
[TBL] [Abstract][Full Text] [Related]
9. Contrast imaging with chirped excitation.
Sun Y; Kruse DE; Ferrara KW
IEEE Trans Ultrason Ferroelectr Freq Control; 2007 Mar; 54(3):520-9. PubMed ID: 17375821
[TBL] [Abstract][Full Text] [Related]
10. Improving the sensitivity of high-frequency subharmonic imaging with coded excitation: a feasibility study.
Shekhar H; Doyley MM
Med Phys; 2012 Apr; 39(4):2049-60. PubMed ID: 22482626
[TBL] [Abstract][Full Text] [Related]
11. Clinical relevance of pressure-dependent scattering at low acoustic pressures.
Emmer M; Vos HJ; van Wamel A; Goertz DE; Versluis M; de Jong N
Ultrasonics; 2007 Dec; 47(1-4):74-7. PubMed ID: 17845809
[TBL] [Abstract][Full Text] [Related]
12. Molecular Acoustic Angiography: A New Technique for High-resolution Superharmonic Ultrasound Molecular Imaging.
Shelton SE; Lindsey BD; Tsuruta JK; Foster FS; Dayton PA
Ultrasound Med Biol; 2016 Mar; 42(3):769-81. PubMed ID: 26678155
[TBL] [Abstract][Full Text] [Related]
13. Wideband harmonic imaging: a novel contrast ultrasound imaging technique.
Bauer A; Hauff P; Lazenby J; von Behren P; Zomack M; Reinhardt M; Schlief R
Eur Radiol; 1999; 9 Suppl 3():S364-7. PubMed ID: 10602930
[TBL] [Abstract][Full Text] [Related]
14. Enhancement of subharmonic emission from encapsulated microbubbles by using a chirp excitation technique.
Zhang D; Gong Y; Gong X; Liu Z; Tan K; Zheng H
Phys Med Biol; 2007 Sep; 52(18):5531-44. PubMed ID: 17804880
[TBL] [Abstract][Full Text] [Related]
15. Radial modulation of microbubbles for ultrasound contrast imaging.
Bouakaz A; Versluis M; Borsboom J; de Jong N
IEEE Trans Ultrason Ferroelectr Freq Control; 2007 Nov; 54(11):2283-90. PubMed ID: 18051162
[TBL] [Abstract][Full Text] [Related]
16. [Ultrasound contrast agents--physical basics].
Kollmann C; Putzer M
Radiologe; 2005 Jun; 45(6):503-12. PubMed ID: 15809841
[TBL] [Abstract][Full Text] [Related]
17. Golay pulse encoding for microbubble contrast imaging in ultrasound.
Leavens C; Williams R; Foster FS; Burns PN; Sherar MD
IEEE Trans Ultrason Ferroelectr Freq Control; 2007 Oct; 54(10):2082-90. PubMed ID: 18019246
[TBL] [Abstract][Full Text] [Related]
18. Observation of contrast agent response to chirp insonation with a simultaneous optical-acoustical system.
Sun Y; Zhao S; Dayton PA; Ferrara KW
IEEE Trans Ultrason Ferroelectr Freq Control; 2006 Jun; 53(6):1130-7. PubMed ID: 16846145
[TBL] [Abstract][Full Text] [Related]
19. Method for microbubble characterization using primary radiation force.
Vos HJ; Guidi F; Boni E; Tortoli P
IEEE Trans Ultrason Ferroelectr Freq Control; 2007 Jul; 54(7):1333-45. PubMed ID: 17718322
[TBL] [Abstract][Full Text] [Related]
20. Stable and transient subharmonic emissions from isolated contrast agent microbubbles.
Biagi E; Breschi L; Vannacci E; Masotti L
IEEE Trans Ultrason Ferroelectr Freq Control; 2007 Mar; 54(3):480-97. PubMed ID: 17375818
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]