These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

137 related articles for article (PubMed ID: 16247305)

  • 1. Computer-assisted guidewire insertion for hip fracture fixation.
    Mayman D; Vasarhelyi EM; Long W; Ellis RE; Rudan J; Pichora DR
    J Orthop Trauma; 2005 Oct; 19(9):610-5. PubMed ID: 16247305
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Navigated osteosynthesis of the proximal femur. An experimental study].
    Hüfner T; Kfuri M; Kendoff D; Richter M; Geerling J; Krettek C
    Unfallchirurg; 2003 Nov; 106(11):975-9. PubMed ID: 14634743
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Three-dimensional computer-assisted navigation for the placement of cannulated hip screws. A pilot study.
    Müller MC; Belei P; Pennekamp PH; Kabir K; Wirtz DC; Burger C; Weber O
    Int Orthop; 2012 Jul; 36(7):1463-9. PubMed ID: 22358174
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Precision of guidewire placement--can it be improved by applying the new, isocentric aiming principle?].
    Suhm N; Toggwiler P; Hänni M; Quarz V; Appelt A
    Unfallchirurg; 2007 May; 110(5):467-74. PubMed ID: 17464495
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Computer-assisted navigation for intramedullary nail fixation of intertrochanteric femur fractures: A randomized, controlled trial.
    Lilly RJ; Koueiter DM; Graner KC; Nowinski GP; Sadowski J; Grant KD
    Injury; 2018 Feb; 49(2):345-350. PubMed ID: 29229219
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Computer-assisted navigation systems for insertion of cannulated screws in femoral neck fractures: a comparison of bi-planar robot navigation with optoelectronic navigation in a Synbone hip model trial.
    Wang JQ; Zhao CP; Su YG; Zhou L; Hu L; Wang TM; Wang MY
    Chin Med J (Engl); 2011 Dec; 124(23):3906-11. PubMed ID: 22442841
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Computer-assisted surgery for dynamic hip screw, using Surgix, a novel intraoperative guiding system.
    Herman A; Dekel A; Botser IB; Steinberg EL
    Int J Med Robot; 2009 Mar; 5(1):45-50. PubMed ID: 19115246
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Evaluation of a 2D fluoroscopy-based navigation system for insertion of femoral neck screws. An experimental study].
    Müller MC; Belei P; de la Fuente M; Strake M; Kabir K; Weber O; Burger C; Radermacher K; Wirtz DC
    Unfallchirurg; 2012 Sep; 115(9):802-10. PubMed ID: 21327810
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Fracture-table-mounted versus bone-mounted dynamic reference frame tracking accuracy using computer-assisted orthopaedic surgery--a comparative study.
    Ilsar I; Weil YA; Joskowicz L; Mosheiff R; Liebergall M
    Comput Aided Surg; 2007 Mar; 12(2):125-30. PubMed ID: 17487662
    [TBL] [Abstract][Full Text] [Related]  

  • 10. 2D projection-based software application for mobile C-arms optimises wire placement in the proximal femur - An experimental study.
    Swartman B; Frere D; Wei W; Schnetzke M; Beisemann N; Keil H; Franke J; Grützner PA; Vetter SY
    Injury; 2017 Oct; 48(10):2068-2073. PubMed ID: 28774707
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Computer-assisted surgery for subtalar arthrodesis. A study in cadavers.
    Easley M; Chuckpaiwong B; Cooperman N; Schuh R; Ogut T; Le IL; Reach J
    J Bone Joint Surg Am; 2008 Aug; 90(8):1628-36. PubMed ID: 18676891
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Sustentacular screw placement with guidance during ORIF of calcaneal fracture: an anatomical specimen study.
    Wang C; Huang D; Ma X; Wang X; Huang J; Zhang C; Chen L; Geng X
    J Orthop Surg Res; 2017 May; 12(1):78. PubMed ID: 28558765
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of a fluoroscopy-based navigation system enabling a virtual radiation-free preview of X-ray images for placement of cannulated hip screws. A cadaver study.
    Müller MC; Belei P; De La Fuente M; Strake M; Weber O; Burger C; Radermacher K; Wirtz DC
    Comput Aided Surg; 2011; 16(1):22-31. PubMed ID: 21198425
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Volume rendering of three-dimensional fluoroscopic images for percutaneous scaphoid fixation: an in vitro study.
    Smith EJ; Al-Sanawi H; Gammon B; Pichora DR; Ellis RE
    Proc Inst Mech Eng H; 2013 Apr; 227(4):384-92. PubMed ID: 23637214
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Placing femoral intramedullary nails in severely bowed femurs.
    Amin NH; Chakravarty R; Jakoi A; Cerynik DL; Toossi N; Harding SP
    Orthopedics; 2014 Mar; 37(3):179-82. PubMed ID: 24762145
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Extracorporeal single dose and radiographic dosage in image-controlled and fluoroscopic navigated pedicle screw implantation].
    Linhardt O; Perlick L; Lüring C; Stern U; Plitz W; Grifka J
    Z Orthop Ihre Grenzgeb; 2005; 143(2):175-9. PubMed ID: 15849636
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of a new computer-assisted surgical planning and navigation system based on two-dimensional fluoroscopy for insertion of a proximal femoral nail: an experimental study.
    Müller MC; Belei P; de la Fuente M; Strake M; Kabir K; Weber O; Radermacher K; Wirtz DC
    Proc Inst Mech Eng H; 2011 May; 225(5):477-86. PubMed ID: 21755777
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Augmented-reality-guided insertion of sliding hip screw guidewire: a preclinical investigation.
    Laverdière C; Corban J; Ge S; Kang Y; Harvey E; Martineau PA; Noel G; Reindl R
    Can J Surg; 2022; 65(3):E364-E371. PubMed ID: 35613719
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Use of an expanded lateral hip view to assist guidewire placement during dynamic hip screw fixation.
    Marsh AG; Ker A
    Ann R Coll Surg Engl; 2014 Nov; 96(8):630. PubMed ID: 25350200
    [No Abstract]   [Full Text] [Related]  

  • 20. Pedicle screw placement in the thoracic spine: a comparison study of computer-assisted navigation and conventional techniques.
    Han W; Gao ZL; Wang JC; Li YP; Peng X; Rui J; Jun W
    Orthopedics; 2010 Aug; 33(8):. PubMed ID: 20704105
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.