These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
115 related articles for article (PubMed ID: 16250471)
21. Dose resolution optimization of polymer gel dosimeters using different monomers. Lepag M; Jayasakera PM; Bäck SA; Baldock C Phys Med Biol; 2001 Oct; 46(10):2665-80. PubMed ID: 11686281 [TBL] [Abstract][Full Text] [Related]
22. Polymer gels for magnetic resonance imaging of radiation dose distributions at normal room atmosphere. Fong PM; Keil DC; Does MD; Gore JC Phys Med Biol; 2001 Dec; 46(12):3105-13. PubMed ID: 11768494 [TBL] [Abstract][Full Text] [Related]
23. Study of the relative dose-response of BANG-3 polymer gel dosimeters in epithermal neutron irradiation. Uusi-Simola J; Savolainen S; Kangasmäki A; Heikkinen S; Perkiö J; Abo Ramadan U; Seppälä T; Karila J; Serén T; Kotiluoto P; Sorvari P; Auterinen I Phys Med Biol; 2003 Sep; 48(17):2895-906. PubMed ID: 14516107 [TBL] [Abstract][Full Text] [Related]
25. Magnetic resonance imaging of radiation dose distributions using a polymer-gel dosimeter. Maryanski MJ; Schulz RJ; Ibbott GS; Gatenby JC; Xie J; Horton D; Gore JC Phys Med Biol; 1994 Sep; 39(9):1437-55. PubMed ID: 15552115 [TBL] [Abstract][Full Text] [Related]
26. The impact of the oxygen scavenger on the dose-rate dependence and dose sensitivity of MAGIC type polymer gels. Khan M; Heilemann G; Kuess P; Georg D; Berg A Phys Med Biol; 2018 Mar; 63(6):06NT01. PubMed ID: 29528035 [TBL] [Abstract][Full Text] [Related]
27. Polymer gels for in-phantom dose imaging in radiotherapy. Vanossi E; Gambarini G; Carrara M; Mariani M Appl Radiat Isot; 2010; 68(4-5):772-5. PubMed ID: 19879155 [TBL] [Abstract][Full Text] [Related]
28. Radiation dose distribution in polymer gels by Raman spectroscopy. Rintoul L; Lepage M; Baldock C Appl Spectrosc; 2003 Jan; 57(1):51-7. PubMed ID: 14610936 [TBL] [Abstract][Full Text] [Related]
29. An evaluation of the dosimetric performance characteristics of N-vinylpyrrolidone-based polymer gels. Papadakis AE; Maris TG; Zacharopoulou F; Pappas E; Zacharakis G; Damilakis J Phys Med Biol; 2007 Aug; 52(16):5069-83. PubMed ID: 17671354 [TBL] [Abstract][Full Text] [Related]
30. Spatial resolution of magnetic resonance imaging Fricke-gel dosimetry is improved with a honeycomb phantom. Silva NA; Nicolucci P; Baffa O Med Phys; 2003 Jan; 30(1):17-20. PubMed ID: 12557973 [TBL] [Abstract][Full Text] [Related]
31. Heterogeneity phantoms for visualization of 3D dose distributions by MRI-based polymer gel dosimetry. Watanabe Y; Mooij R; Perera GM; Maryanski MJ Med Phys; 2004 May; 31(5):975-84. PubMed ID: 15191281 [TBL] [Abstract][Full Text] [Related]
32. Improved MAGIC gel for higher sensitivity and elemental tissue equivalent 3D dosimetry. Zhu X; Reese TG; Crowley EM; El Fakhri G Med Phys; 2010 Jan; 37(1):183-8. PubMed ID: 20175480 [TBL] [Abstract][Full Text] [Related]
33. Experimental study of attenuation properties of normoxic polymer gel dosimeters. Brindha S; Venning AJ; Hill B; Baldock C Phys Med Biol; 2004 Oct; 49(20):N353-61. PubMed ID: 15566179 [TBL] [Abstract][Full Text] [Related]
34. Dose integration characteristics in normoxic polymer gel dosimetry investigated using sequential beam irradiation. Karlsson A; Gustavsson H; Månsson S; McAuley KB; Bäck SA Phys Med Biol; 2007 Aug; 52(15):4697-706. PubMed ID: 17634658 [TBL] [Abstract][Full Text] [Related]
36. A novel quantification method for low-density gel dosimeter. Nedaie HA; Pak F; Vaezzadeh V; Eqlimi E; Takavar A; Saligheh Rad HR; Mosleh Shirazi MA; Mirheydari M J Cancer Res Ther; 2018; 14(2):292-299. PubMed ID: 29516909 [TBL] [Abstract][Full Text] [Related]
37. Optical imaging of dose distributions in Fricke gels. Viti V; d'Errico F; Pacilio M; Luciani AM; Palma A; Grande S; Ranghiasci C; Adorante N; Guidoni L; Rosi A; Ranade M; de Pasquale F; Barone P; Sebastiani G Radiat Prot Dosimetry; 2006; 120(1-4):148-50. PubMed ID: 16614085 [TBL] [Abstract][Full Text] [Related]