These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

175 related articles for article (PubMed ID: 16253826)

  • 61. [Diagnosis of thoracic aorta dissection using transesophageal echocardiography].
    Hernández Herrera C; Morón-Malek A; Romero-Cárdenas A; Rijlaarsdam M; Vargas-Barrón J
    Arch Inst Cardiol Mex; 1994; 64(2):183-8. PubMed ID: 8074589
    [TBL] [Abstract][Full Text] [Related]  

  • 62. Aortic dissection.
    Della Croce H
    RN; 2007 Mar; 70(3):26-31; quiz 32. PubMed ID: 17405360
    [No Abstract]   [Full Text] [Related]  

  • 63. [Aortic dissection, sometimes a difficult diagnosis].
    Haanen JB; van Dijkman PR
    Ned Tijdschr Geneeskd; 1995 Apr; 139(14):705-9. PubMed ID: 7731464
    [No Abstract]   [Full Text] [Related]  

  • 64. Evaluation of an aortic annular pseudoaneurysm by MRI: comparison with echocardiography, angiography and surgery.
    Akins EW; Limacher M; Slone RM; Hill JA
    Cardiovasc Intervent Radiol; 1987; 10(4):188-93. PubMed ID: 3115572
    [TBL] [Abstract][Full Text] [Related]  

  • 65. Unexpected aortic dissection.
    Pipilis A; Kaliambakos S; Xenodochidis C; Georgiou T; Andreou I; Pattakos S
    Hellenic J Cardiol; 2005; 46(6):428-9. PubMed ID: 16422130
    [No Abstract]   [Full Text] [Related]  

  • 66. [Acute aortic dissecting: contribution of transesophageal echography. Apropos of 10 cases].
    Chevalier JM; Roudaut R; Egloff P; Coste P; Durandet P; Besse P; Dallocchio M
    Ann Med Interne (Paris); 1991; 142(1):9-12. PubMed ID: 2048884
    [TBL] [Abstract][Full Text] [Related]  

  • 67. Magnetic resonance imaging of dissection in pseudocoarctation of the aorta.
    Safir J; Kerr A; Morehouse H; Frost A; Berman H
    Cardiovasc Intervent Radiol; 1993; 16(3):180-2. PubMed ID: 8334690
    [TBL] [Abstract][Full Text] [Related]  

  • 68. Aortic dissection: the tear that kills.
    Yee CA
    Nurs Manage; 2004 Feb; 35(2):25-32. PubMed ID: 14767230
    [TBL] [Abstract][Full Text] [Related]  

  • 69. [Aortic aneurysms and aortic dissection. Computed tomography - angiography - sonography (author's transl)].
    Brecht G; Harder T
    Rofo; 1981 Oct; 135(4):388-98. PubMed ID: 6212352
    [TBL] [Abstract][Full Text] [Related]  

  • 70. Surgery of the thoracic aorta.
    Kouchoukos NT; Dougenis D
    N Engl J Med; 1997 Jun; 336(26):1876-88. PubMed ID: 9197217
    [No Abstract]   [Full Text] [Related]  

  • 71. Aortic pathology: aortic trauma, debris, dissection, and aneurysm.
    Khalil A; Helmy T; Porembka DT
    Crit Care Med; 2007 Aug; 35(8 Suppl):S392-400. PubMed ID: 17667464
    [TBL] [Abstract][Full Text] [Related]  

  • 72. [Recent progress of diagnostic imaging for aortic dissection].
    Takamiya M; Kuribayashi S; Hamada S; Iino M
    Nihon Geka Gakkai Zasshi; 1996 Oct; 97(10):884-9. PubMed ID: 8968990
    [TBL] [Abstract][Full Text] [Related]  

  • 73. Magnetic resonance imaging of isolated abdominal aortic dissection.
    Gendal ES; Mendelson DS; Janus CL; Golinko RJ
    Clin Imaging; 1989 Sep; 13(3):217-9. PubMed ID: 2684372
    [TBL] [Abstract][Full Text] [Related]  

  • 74. Clinical, diagnostic, and management perspectives of aortic dissection.
    Khan IA; Nair CK
    Chest; 2002 Jul; 122(1):311-28. PubMed ID: 12114376
    [TBL] [Abstract][Full Text] [Related]  

  • 75. Diagnosis of dissecting aortic aneurysm with suprasternal echocardiography.
    Kasper W; Meinertz T; Kersting F; Lang K; Just H
    Am J Cardiol; 1978 Aug; 42(2):291-4. PubMed ID: 685842
    [TBL] [Abstract][Full Text] [Related]  

  • 76. A new method for quantification of false lumen thrombosis in aortic dissection using magnetic resonance imaging and a blood pool contrast agent.
    Clough RE; Hussain T; Uribe S; Greil GF; Razavi R; Taylor PR; Schaeffter T; Waltham M
    J Vasc Surg; 2011 Nov; 54(5):1251-8. PubMed ID: 21906904
    [TBL] [Abstract][Full Text] [Related]  

  • 77. Giant ascending aortic aneurysm with type a dissection diagnosed by aortography.
    Pai RK; Osborn LA
    Cardiol Rev; 2004; 12(2):106. PubMed ID: 14766025
    [No Abstract]   [Full Text] [Related]  

  • 78. [Intravascular ultrasound in patients with suspected aortic dissection: comparison with transesophageal echocardiography].
    Görge G; Erbel R; Gerber T; Ge J; Zamorano J; Mackowski T; Nixdorff U; Mohr-Kahaly S; Meyer J
    Z Kardiol; 1992 Jan; 81(1):37-43. PubMed ID: 1570727
    [TBL] [Abstract][Full Text] [Related]  

  • 79. Choice of computed tomography, transesophageal echocardiography, magnetic resonance imaging, and aortography in acute aortic dissection: International Registry of Acute Aortic Dissection (IRAD).
    Moore AG; Eagle KA; Bruckman D; Moon BS; Malouf JF; Fattori R; Evangelista A; Isselbacher EM; Suzuki T; Nienaber CA; Gilon D; Oh JK
    Am J Cardiol; 2002 May; 89(10):1235-8. PubMed ID: 12008187
    [No Abstract]   [Full Text] [Related]  

  • 80. Coronary artery disease in patients with type A aortic dissection.
    Creswell LL; Kouchoukos NT; Cox JL; Rosenbloom M
    Ann Thorac Surg; 1995 Mar; 59(3):585-90. PubMed ID: 7887694
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.