BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

177 related articles for article (PubMed ID: 16261826)

  • 1. In vitro biomechanical comparison of a plate-rod combination-construct and an interlocking nail-construct for experimentally induced gap fractures in canine tibiae.
    von Pfeil DJ; Déjardin LM; DeCamp CE; Meyer EG; Lansdowne JL; Weerts RJ; Haut RC
    Am J Vet Res; 2005 Sep; 66(9):1536-43. PubMed ID: 16261826
    [TBL] [Abstract][Full Text] [Related]  

  • 2. An in vitro biomechanical comparison of interlocking nail constructs and double plating for fixation of diaphyseal femur fractures in immature horses.
    Radcliffe RM; Lopez MJ; Turner TA; Watkins JP; Radcliffe CH; Markel MD
    Vet Surg; 2001; 30(2):179-90. PubMed ID: 11230773
    [TBL] [Abstract][Full Text] [Related]  

  • 3. An in vitro biomechanical comparison of an interlocking nail system and dynamic compression plate fixation of ostectomized equine third metacarpal bones.
    Lopez MJ; Wilson DG; Vanderby R; Markel MD
    Vet Surg; 1999; 28(5):333-40. PubMed ID: 10493637
    [TBL] [Abstract][Full Text] [Related]  

  • 4. An in vitro biomechanical comparison of two interlocking-nail systems for fixation of ostectomized equine third metacarpal bones.
    Lopez MJ; Wilson DG; Trostle SS; Markel MD
    Vet Surg; 2001; 30(3):246-52. PubMed ID: 11340556
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Biomechanical comparison of mono- and bicortical screws in an experimentally induced gap fracture.
    Demner D; Garcia TC; Serdy MG; Hayashi K; Nir BA; Stover SM
    Vet Comp Orthop Traumatol; 2014; 27(6):422-9. PubMed ID: 25327936
    [TBL] [Abstract][Full Text] [Related]  

  • 6. An in vitro biomechanical study of bone plate and interlocking nail in a canine diaphyseal femoral fracture model.
    Bernarde A; Diop A; Maurel N; Viguier E
    Vet Surg; 2001; 30(5):397-408. PubMed ID: 11555814
    [TBL] [Abstract][Full Text] [Related]  

  • 7. In vitro mechanical evaluation of torsional loading in simulated canine tibiae for a novel hourglass-shaped interlocking nail with a self-tapping tapered locking design.
    Déjardin LM; Lansdowne JL; Sinnott MT; Sidebotham CG; Haut RC
    Am J Vet Res; 2006 Apr; 67(4):678-85. PubMed ID: 16579762
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Biomechanical comparison of a locking compression plate combined with an intramedullary pin or a polyetheretherketone rod in a cadaveric canine tibia gap model.
    Beierer LH; Glyde M; Day RE; Hosgood GL
    Vet Surg; 2014 Nov; 43(8):1032-8. PubMed ID: 25132257
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of the mechanical behaviors of semicontoured, locking plate-rod fixation and anatomically contoured, conventional plate-rod fixation applied to experimentally induced gap fractures in canine femora.
    Goh CS; Santoni BG; Puttlitz CM; Palmer RH
    Am J Vet Res; 2009 Jan; 70(1):23-9. PubMed ID: 19119945
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Biomechanical comparison of two alternative tibial plateau leveling osteotomy plates with the original standard in an axially loaded gap model: an in vitro study.
    Kloc PA; Kowaleski MP; Litsky AS; Brown NO; Johnson KA
    Vet Surg; 2009 Jan; 38(1):40-8. PubMed ID: 19152616
    [TBL] [Abstract][Full Text] [Related]  

  • 11. In vitro cyclic biomechanical properties of an interlocking equine tibial nail.
    McDuffee LA; Stover SM; Taylor KT
    Vet Surg; 2000; 29(2):163-72. PubMed ID: 10730709
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Biomechanical comparison of a 3.5-mm conical coupling plating system and a 3.5-mm locking compression plate applied as plate-rod constructs to an experimentally created fracture gap in femurs of canine cadavers.
    Tremolada G; Lewis DD; Paragnani KL; Conrad BP; Kim SE; Pozzi A
    Am J Vet Res; 2017 Jun; 78(6):712-717. PubMed ID: 28541152
    [TBL] [Abstract][Full Text] [Related]  

  • 13. In vitro biomechanical comparison of 3.5 string of pearl plate fixation to 3.5 locking compression plate fixation in a canine fracture gap model.
    Malenfant RC; Sod GA
    Vet Surg; 2014 May; 43(4):465-70. PubMed ID: 24720361
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Mechanical evaluation of a novel angle-stable interlocking nail in a gap fracture model.
    Deprey J; Blondel M; Saban C; Massenzio M; Gauthier O; Moissonnier P; Viguier E; Cachon T
    Vet Surg; 2022 Nov; 51(8):1247-1256. PubMed ID: 35675144
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Ex vivo biomechanical evaluation of 2.4 mm LCP plate rod constructs versus 2.7 mm LCP applied to the feline tibia.
    Gutbrod A; Longo F; Affentranger R; Ferguson SJ; Pozzi A; Knell SC
    Vet Surg; 2024 May; 53(4):710-716. PubMed ID: 37818951
    [TBL] [Abstract][Full Text] [Related]  

  • 16. An in vitro biomechanical investigation of the mechanical properties of dynamic compression plated osteotomized adult equine tibiae.
    McDuffee LA; Stover SM; Taylor KT
    Vet Surg; 1997; 26(2):126-36. PubMed ID: 9068163
    [TBL] [Abstract][Full Text] [Related]  

  • 17. In vivo biomechanical evaluation of a novel angle-stable interlocking nail design in a canine tibial fracture model.
    Déjardin LM; Cabassu JB; Guillou RP; Villwock M; Guiot LP; Haut RC
    Vet Surg; 2014 Mar; 43(3):271-81. PubMed ID: 24467692
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effect of Intramedullary Rod Diameter on a String of Pearls Plate-Rod Construct in Mediolateral Bending: An In Vitro Mechanical Study.
    Rutherford S; Demianiuk RM; Benamou J; Beckett C; Ness MG; Déjardin LM
    Vet Surg; 2015 Aug; 44(6):737-43. PubMed ID: 26088717
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The effect of concurrent fibular fracture on the fixation of distal tibia fractures: a laboratory comparison of intramedullary nails with locked plates.
    Strauss EJ; Alfonso D; Kummer FJ; Egol KA; Tejwani NC
    J Orthop Trauma; 2007 Mar; 21(3):172-7. PubMed ID: 17473753
    [TBL] [Abstract][Full Text] [Related]  

  • 20. An in vitro biomechanical investigation of an interlocking nail for fixation of diaphyseal tibial fractures in adult horses.
    McDuffee LA; Stover SM; Taylor KT; Les CM
    Vet Surg; 1994; 23(4):219-30. PubMed ID: 8091624
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.