These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
115 related articles for article (PubMed ID: 16266102)
1. Measurement of CT radiation profile width using CR imaging plates. Liu HL; Liu RR; Reeve DM; Shepard SJ; Willis CE Med Phys; 2005 Sep; 32(9):2881-7. PubMed ID: 16266102 [TBL] [Abstract][Full Text] [Related]
2. Evaluation of different techniques for CT radiation profile width measurement. Jackson SR; Ahmad S; Hu Y; Ruan C J Appl Clin Med Phys; 2013 Jul; 14(4):4122. PubMed ID: 23835377 [TBL] [Abstract][Full Text] [Related]
3. An investigation into factors affecting the precision of CT radiation dose profile width measurements using radiochromic films. Li B; Behrman RH Med Phys; 2015 Apr; 42(4):1765-72. PubMed ID: 25832066 [TBL] [Abstract][Full Text] [Related]
4. Measurement of CT scanner dose profiles in a filmless department. Thomson FJ Australas Phys Eng Sci Med; 2005 Sep; 28(3):179-83. PubMed ID: 16250473 [TBL] [Abstract][Full Text] [Related]
5. CT radiation profile width measurement using CR imaging plate raw data. Bjarnason TA; Yang CY J Appl Clin Med Phys; 2015 Nov; 16(6):501-507. PubMed ID: 26699559 [TBL] [Abstract][Full Text] [Related]
6. [Reusable imaging plate (IP) for swift and automatic measurement of X-ray CT dose profiles]. Sekine R; Kimura H; Muramatsu Y; Murakami T; Saotome S; Moriyama N Nihon Hoshasen Gijutsu Gakkai Zasshi; 2004 Jan; 60(1):69-70. PubMed ID: 15041908 [TBL] [Abstract][Full Text] [Related]
7. [Measurement Accuracy of CT Beam Width with a Portable Flat-panel Detector]. Ichikawa N; Matsubara K; Fukuda A; Yamamoto H Nihon Hoshasen Gijutsu Gakkai Zasshi; 2020; 76(2):161-167. PubMed ID: 32074524 [TBL] [Abstract][Full Text] [Related]
8. Radiation dose assessment in a 320-detector-row CT scanner used in cardiac imaging. Gomà C; Ruiz A; Jornet N; Latorre A; Pallerol RM; Carrasco P; Eudaldo T; Ribas M Med Phys; 2011 Mar; 38(3):1473-80. PubMed ID: 21520859 [TBL] [Abstract][Full Text] [Related]
10. The measurement of radiation dose profiles for electron-beam computed tomography using film dosimetry. Zink FE; McCollough CH Med Phys; 1994 Aug; 21(8):1287-91. PubMed ID: 7799873 [TBL] [Abstract][Full Text] [Related]
11. The use of pencil ionization chamber with temporal readout capabilities to measure CT beam full width half maximum. Fadhel MN; Grizzard K; Vergara D; Franco RP; Zhao A; Hoerner M Med Phys; 2024 Jul; 51(7):4687-4695. PubMed ID: 38758726 [TBL] [Abstract][Full Text] [Related]
12. Measurement of focal spot size with slit camera using computed radiography and flat-panel based digital detectors. Rong XJ; Krugh KT; Shepard SJ; Geiser WR Med Phys; 2003 Jul; 30(7):1768-75. PubMed ID: 12906194 [TBL] [Abstract][Full Text] [Related]
13. [Influence of Detector Radiation Damage on CR Mammography Quality Control]. Moriwaki A; Ishii M; Terazono S; Arao K; Ishii R; Sanada T; Yoshida A Nihon Hoshasen Gijutsu Gakkai Zasshi; 2016 May; 72(5):424-9. PubMed ID: 27211088 [TBL] [Abstract][Full Text] [Related]
14. On the use of computed radiography plates for quality assurance of intensity modulated radiation therapy dose distributions. Day RA; Sankar AP; Nailon WH; MacLeod AS Med Phys; 2011 Feb; 38(2):632-45. PubMed ID: 21452701 [TBL] [Abstract][Full Text] [Related]