BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

236 related articles for article (PubMed ID: 16269043)

  • 1. Fingerprick blood samples can be used to accurately measure tacrolimus levels by tandem mass spectrometry.
    Webb NJ; Roberts D; Preziosi R; Keevil BG
    Pediatr Transplant; 2005 Dec; 9(6):729-33. PubMed ID: 16269043
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Dried blood spot measurement: application in tacrolimus monitoring using limited sampling strategy and abbreviated AUC estimation.
    Cheung CY; van der Heijden J; Hoogtanders K; Christiaans M; Liu YL; Chan YH; Choi KS; van de Plas A; Shek CC; Chau KF; Li CS; van Hooff J; Stolk L
    Transpl Int; 2008 Feb; 21(2):140-5. PubMed ID: 17944802
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Home fingerprick sampling for immunosuppressant drug monitoring in pediatric renal transplant patients.
    Acott PD
    Nat Clin Pract Nephrol; 2006 Jun; 2(6):304-5. PubMed ID: 16932447
    [No Abstract]   [Full Text] [Related]  

  • 4. Cloned enzyme donor immunoassay tacrolimus assay compared with high-performance liquid chromatography-tandem mass spectrometry and microparticle enzyme immunoassay in liver and renal transplant recipients.
    Westley IS; Taylor PJ; Salm P; Morris RG
    Ther Drug Monit; 2007 Oct; 29(5):584-91. PubMed ID: 17898648
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Measurement of total homocysteine in plasma and blood spots using liquid chromatography-tandem mass spectrometry: comparison with the plasma Abbott IMx method.
    McCann SJ; Gillingwater S; Keevil BG; Cooper DP; Morris MR
    Ann Clin Biochem; 2003 Mar; 40(Pt 2):161-5. PubMed ID: 12662404
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Analytical performance characteristics of the Abbott Architect i2000 Tacrolimus assay; comparisons with liquid chromatography-tandem mass spectrometry (LC-MS/MS) and Abbott IMx methods.
    De BK; Jimenez E; De S; Sawyer JC; McMillin GA
    Clin Chim Acta; 2009 Dec; 410(1-2):25-30. PubMed ID: 19751714
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Liquid chromatography-mass spectrometry measurement of tacrolimus in finger-prick samples compared with venous whole blood samples.
    Keevil BG; Fildes J; Baynes A; Yonan N
    Ann Clin Biochem; 2009 Mar; 46(Pt 2):144-5. PubMed ID: 19151171
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Clinical outcomes of renal transplantation using liquid chromatographic monitoring of tacrolimus.
    Borrows R; Chusney G; Loucaidou M; James A; Stichbury J; Van Tromp J; Cairns T; Griffith M; Hakim N; McLean A; Palmer A; Papalois V; Taube D
    Ther Drug Monit; 2006 Apr; 28(2):269-73. PubMed ID: 16628143
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Measurement of tacrolimus in blood with the method of high performance liquid chromatography-mass spectrometry].
    Li YL; Wang M; Tang ZY
    Zhonghua Yi Xue Za Zhi; 2008 Aug; 88(32):2290-4. PubMed ID: 19087682
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Monitoring of cyclosporine levels in transplant recipients using self-administered fingerprick sampling.
    Yonan N; Martyszczuk R; Machaal A; Baynes A; Keevil BG
    Clin Transplant; 2006; 20(2):221-5. PubMed ID: 16640530
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Performance of a no-pretreatment tacrolimus assay on the Dade Behring Dimension RxL clinical chemistry analyzer.
    Griffey MA; Hock KG; Kilgore DC; Wei TQ; Duh SH; Christenson R; Scott MG
    Clin Chim Acta; 2007 Sep; 384(1-2):48-51. PubMed ID: 17588555
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Robust, high-throughput LC-MS/MS method for therapeutic drug monitoring of cyclosporine, tacrolimus, everolimus, and sirolimus in whole blood.
    Koster RA; Dijkers EC; Uges DR
    Ther Drug Monit; 2009 Feb; 31(1):116-25. PubMed ID: 19065123
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Simultaneous measurement of cyclosporin A and tacrolimus from dried blood spots by ultra high performance liquid chromatography tandem mass spectrometry.
    Hinchliffe E; Adaway JE; Keevil BG
    J Chromatogr B Analyt Technol Biomed Life Sci; 2012 Feb; 883-884():102-7. PubMed ID: 21680259
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of a rapid micro-scale assay for tacrolimus by liquid chromatography-tandem mass spectrometry.
    Keevil BG; McCann SJ; Cooper DP; Morris MR
    Ann Clin Biochem; 2002 Sep; 39(Pt 5):487-92. PubMed ID: 12227855
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Rapid and simultaneous determination of tacrolimus (FK506) and diltiazem in human whole blood by liquid chromatography-tandem mass spectrometry: application to a clinical drug-drug interaction study.
    Li JL; Wang XD; Wang CX; Fu Q; Liu LS; Huang M; Zhou SF
    J Chromatogr B Analyt Technol Biomed Life Sci; 2008 May; 867(1):111-8. PubMed ID: 18417431
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of an immunoassay (Abbott-IMX Analyzer) allowing routine determination of sirolimus: comparison with LC-MS method.
    Bargnoux AS; Bonardet A; Chong G; Garrigue V; Deleuze S; Dupuy AM; Mourad G; Cristol JP
    Transplant Proc; 2006 Sep; 38(7):2352-3. PubMed ID: 16980087
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Therapeutic drug monitoring of tacrolimus with the dried blood spot method.
    Hoogtanders K; van der Heijden J; Christiaans M; Edelbroek P; van Hooff JP; Stolk LM
    J Pharm Biomed Anal; 2007 Jul; 44(3):658-64. PubMed ID: 17184953
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A high-performance liquid chromatography-mass spectrometry method using a novel atmospheric pressure chemical ionization approach for the rapid simultaneous measurement of tacrolimus and cyclosporin in whole blood.
    Salm P; Taylor PJ; Rooney F
    Ther Drug Monit; 2008 Jun; 30(3):292-300. PubMed ID: 18520600
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of the reintroduced MEIA assay with HPLC-MS/MS for the determination of whole-blood sirolimus from transplant recipients.
    Morris RG; Salm P; Taylor PJ; Wicks FA; Theodossi A
    Ther Drug Monit; 2006 Apr; 28(2):164-8. PubMed ID: 16628125
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Tacrolimus monitoring in renal transplantation: a comparison between high-performance liquid chromatography and immunoassay.
    Borrows R; Chusney G; Loucaidou M; Singh S; James A; Stichbury J; Van Tromp J; Cairns T; Griffith M; Hakim N; McLean A; Palmer A; Papalois V; Taube D
    Transplant Proc; 2005 May; 37(4):1733-5. PubMed ID: 15919448
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.