These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

213 related articles for article (PubMed ID: 16269233)

  • 21. [New aspects of minimally invasive cardiac output monitoring].
    Hofer CK; Schmid U; Zollinger A
    Anasthesiol Intensivmed Notfallmed Schmerzther; 2012 Feb; 47(2):102-9. PubMed ID: 22402849
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Intraoperative hemodynamic monitoring during organ transplantation: what is new?
    Della Rocca G; Brondani A; Costa MG
    Curr Opin Organ Transplant; 2009 Jun; 14(3):291-6. PubMed ID: 19448537
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [Non-invasive determination of cardiac output by continuous wave Doppler in air rescue service].
    Knobloch K; Hubrich V; Rohmann P; Lüpkemann M; Phillips R; Gerich T; Krettek C
    Anasthesiol Intensivmed Notfallmed Schmerzther; 2005 Dec; 40(12):750-5. PubMed ID: 16362876
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Cardiac output measurement in pediatric anesthesia.
    Skowno JJ; Broadhead M
    Paediatr Anaesth; 2008 Nov; 18(11):1019-28. PubMed ID: 18717806
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Perioperative hemodynamic monitoring with transesophageal Doppler technology.
    Schober P; Loer SA; Schwarte LA
    Anesth Analg; 2009 Aug; 109(2):340-53. PubMed ID: 19608800
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Comparison of cardiac output measurement using the CardioQP oesophageal Doppler with cardiac output measurement using thermodilution technique in children during heart catheterisation.
    ; Knirsch W; Kretschmar O; Tomaske M; Stutz K; Nagdyman N; Balmer C; Schmitz A; Berger F; Bauersfeld U; Weiss M
    Anaesthesia; 2008 Aug; 63(8):851-5. PubMed ID: 18557743
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Nurse-determined assessment of cardiac output. Comparing a non-invasive cardiac output device and pulmonary artery catheter: a prospective observational study.
    Corley A; Barnett AG; Mullany D; Fraser JF
    Int J Nurs Stud; 2009 Oct; 46(10):1291-7. PubMed ID: 19423107
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [Utility of monitoring with the PiCCO system during lung resection surgery].
    Aguilera LG; Ramos I; Pacreu S; Baldomà N; Ortiz M; Martín C
    Rev Esp Anestesiol Reanim; 2007 Nov; 54(9):543-6. PubMed ID: 18085107
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [Is there any indication for perioperative use of the pulmonary artery catheter?].
    Schürholz T; Marx G
    Anasthesiol Intensivmed Notfallmed Schmerzther; 2012 Feb; 47(2):110-7. PubMed ID: 22402850
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Anesthetic management for removal of a giant ovarian tumor by monitoring transesophageal Doppler cardiac output].
    Ohkubo S; Tanaka N; Takasaki M
    Masui; 2004 Sep; 53(9):1061-4. PubMed ID: 15500113
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Cardiac output monitoring.
    de Waal EE; Wappler F; Buhre WF
    Curr Opin Anaesthesiol; 2009 Feb; 22(1):71-7. PubMed ID: 19295295
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [Hemodynamic monitoring from the data of intracardiac and transesophageal echocardiography].
    Sandrikov VA; Revunenkov GV; Doroshenko DA; Eremenko AA
    Anesteziol Reanimatol; 2009; (6):38-42. PubMed ID: 20099647
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Cardiac output measurement in patients undergoing liver transplantation: pulmonary artery catheter versus uncalibrated arterial pressure waveform analysis.
    Biais M; Nouette-Gaulain K; Cottenceau V; Vallet A; Cochard JF; Revel P; Sztark F
    Anesth Analg; 2008 May; 106(5):1480-6, table of contents. PubMed ID: 18420863
    [TBL] [Abstract][Full Text] [Related]  

  • 34. [Comparison of cardiac output measured by pulseCO and that by vigilance during inferior vena cava clamping].
    Tsujimoto Y; Tsutsui M; Kazama T; Ogura T; Fukuda I
    Masui; 2005 Oct; 54(10):1138-42. PubMed ID: 16231769
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [Transesophageal echocardiography--new possibilities of peroperative monitoring of cardiac hemodynamics].
    Kozáková M; Matuszczyková L
    Vnitr Lek; 1990 Jul; 36(7):685-92. PubMed ID: 2247971
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Cardiac output measurement during infrarenal aortic surgery: echo-esophageal Doppler versus thermodilution catheter.
    Lafanechère A; Albaladejo P; Raux M; Geeraerts T; Bocquet R; Wernet A; Castier Y; Marty J
    J Cardiothorac Vasc Anesth; 2006 Feb; 20(1):26-30. PubMed ID: 16458209
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Continuous cardiac output measurement: arterial pressure analysis versus thermodilution technique during cardiac surgery with cardiopulmonary bypass.
    Lorsomradee S; Lorsomradee SR; Cromheecke S; De Hert SG
    Anaesthesia; 2007 Oct; 62(10):979-83. PubMed ID: 17845647
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Transpulmonary thermodilution hemodynamic monitoring for pheochromocytoma surgery in a child with complex congenital heart disease.
    Cherqaoui I; Raux O; Dehour L; Rochette A; Dadure C; Capdevila X
    Paediatr Anaesth; 2006 Dec; 16(12):1277-80. PubMed ID: 17121560
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Transpulmonary versus continuous thermodilution cardiac output after valvular and coronary artery surgery.
    Breukers RM; Groeneveld AB; de Wilde RB; Jansen JR
    Interact Cardiovasc Thorac Surg; 2009 Jul; 9(1):4-8. PubMed ID: 19383638
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Changes in therapeutic attitude based on transesophageal echocardiography in cardiac surgery].
    Arranz J; Riesgo M; Moreno M; García-Fernández MA; Navia J
    Rev Esp Anestesiol Reanim; 1998 Jan; 45(1):27-9. PubMed ID: 9558935
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.