3. Decrease in amplitude of intracardiac ventricular electrogram and inappropriate therapy in patients with an implantable cardioverter defibrillator. Watanabe H; Chinushi M; Izumi D; Sato A; Okada S; Okamura K; Komura S; Hosaka Y; Furushima H; Washizuka T; Aizawa Y Int Heart J; 2006 May; 47(3):363-70. PubMed ID: 16823242 [TBL] [Abstract][Full Text] [Related]
4. Multiple appropriate and spurious defibrillator shocks in a patient with right ventricular cardiomyopathy. Strohmer B; Schernthaner C; Pichler M Int J Cardiol; 2005 Jul; 102(2):363-6. PubMed ID: 15982515 [TBL] [Abstract][Full Text] [Related]
5. Development and testing of an algorithm to detect implantable cardioverter-defibrillator lead failure. Gunderson BD; Gillberg JM; Wood MA; Vijayaraman P; Shepard RK; Ellenbogen KA Heart Rhythm; 2006 Feb; 3(2):155-62. PubMed ID: 16443529 [TBL] [Abstract][Full Text] [Related]
6. An inappropriate pacing threshold increase after repeated electrical storm in a patient with implantable cardioverter defibrillator. Zhu Y; Gu X; Xu C BMC Cardiovasc Disord; 2017 Oct; 17(1):265. PubMed ID: 29037154 [TBL] [Abstract][Full Text] [Related]
7. Multicenter investigation of an implantable cardioverter-defibrillator algorithm to detect oversensing. Welte N; Strik M; Eschalier R; Mondoly P; Defaye P; Frontera A; Ritter P; Haïssaguerre M; Ploux S; Koneru J; Ellenbogen KA; Bordachar P Heart Rhythm; 2017 Jul; 14(7):1008-1015. PubMed ID: 28323174 [TBL] [Abstract][Full Text] [Related]
8. Transvenous defibrillation leads: high incidence of failure during long-term follow-up. Dorwarth U; Frey B; Dugas M; Matis T; Fiek M; Schmoeckel M; Remp T; Durchlaub I; Gerth A; Steinbeck G; Hoffmann E J Cardiovasc Electrophysiol; 2003 Jan; 14(1):38-43. PubMed ID: 12625608 [TBL] [Abstract][Full Text] [Related]
9. Causes of ventricular oversensing in implantable cardioverter-defibrillators: implications for diagnosis of lead fracture. Gunderson BD; Swerdlow CD; Wilcox JM; Hayman JE; Ousdigian KT; Ellenbogen KA Heart Rhythm; 2010 May; 7(5):626-33. PubMed ID: 20184977 [TBL] [Abstract][Full Text] [Related]
10. An algorithm to predict implantable cardioverter-defibrillator lead failure. Gunderson BD; Patel AS; Bounds CA; Shepard RK; Wood MA; Ellenbogen KA J Am Coll Cardiol; 2004 Nov; 44(9):1898-902. PubMed ID: 15519026 [TBL] [Abstract][Full Text] [Related]
11. Oversensing during ventricular pacing in patients with a third-generation implantable cardioverter-defibrillator. Kelly PA; Mann DE; Damle RS; Reiter MJ J Am Coll Cardiol; 1994 Jun; 23(7):1531-4. PubMed ID: 8195509 [TBL] [Abstract][Full Text] [Related]
12. Transvenous cardioverter defibrillator lead malfunction due to terminal connector damage in pectoral implants. Mera F; DeLurgio DB; Langberg JJ; Moss EA; Léon AR Pacing Clin Electrophysiol; 1999 Dec; 22(12):1797-801. PubMed ID: 10642134 [TBL] [Abstract][Full Text] [Related]
13. Subcutaneous Implantable Cardioverter Defibrillator Lead Repositioning for Preventing Inappropriate Shocks Due to Myopotential Oversensing in a Post-Fulminant Myocarditis Patient. Sasaki T; Nakamura K; Naito S Int Heart J; 2019 Mar; 60(2):466-469. PubMed ID: 30745542 [TBL] [Abstract][Full Text] [Related]
15. [High incidence of isolator fractures in transvenous implantation of cardioverter defibrillators]. Mewis C; Kühlkamp V; Dörnberger V; Mermi J; Seipel L Z Kardiol; 1997 Feb; 86(2):85-94. PubMed ID: 9173702 [TBL] [Abstract][Full Text] [Related]
16. Non-determinable defibrillation threshold and inefficacy of implantable cardioverter/defibrillator shocks due to defective connections of the defibrillator lead terminals in the device header port. Maagh P; Trappe HJ; Meissner A Europace; 2007 Dec; 9(12):1161-2. PubMed ID: 17913694 [TBL] [Abstract][Full Text] [Related]
17. Development of ventricular fibrillations with different characteristics in the local electrocardiogram: large and small amplitude of activation, and its implication for implantable cardioverter defibrillator treatment. Chinushi M; Washizuka T; Kasai H; Ohhira K; Satoh M; Aizawa Y Jpn Circ J; 1999 Dec; 63(12):1007-10. PubMed ID: 10614851 [TBL] [Abstract][Full Text] [Related]
18. [Problems and complications after implantation of automatic defibrillators]. Trappe HJ; Klein H; Fieguth HG; Wenzlaff P; Lichtlen PR Med Klin (Munich); 1993 Nov; 88(11):619-28. PubMed ID: 8295602 [TBL] [Abstract][Full Text] [Related]