These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
9. Upper limit of vulnerability is a good estimator of shock strength associated with 90% probability of successful defibrillation in humans with transvenous implantable cardioverter-defibrillators. Swerdlow CD; Ahern T; Kass RM; Davie S; Mandel WJ; Chen PS J Am Coll Cardiol; 1996 Apr; 27(5):1112-8. PubMed ID: 8609329 [TBL] [Abstract][Full Text] [Related]
10. Transthoracic electrical impedance during external defibrillation: comparison of measured and modelled waveforms. Al Hatib F; Trendafilova E; Daskalov I Physiol Meas; 2000 Feb; 21(1):145-53. PubMed ID: 10720010 [TBL] [Abstract][Full Text] [Related]
11. Pediatric defibrillation: current flow is improved by using "adult" electrode paddles. Atkins DL; Kerber RE Pediatrics; 1994 Jul; 94(1):90-3. PubMed ID: 8008545 [TBL] [Abstract][Full Text] [Related]
12. Defibrillation and cardioversion. Rogove HJ; Hughes CM Crit Care Clin; 1992 Oct; 8(4):839-63. PubMed ID: 1393754 [TBL] [Abstract][Full Text] [Related]
13. A comparison of defibrillation efficacy between different impedance compensation techniques in high impedance porcine model. Li Y; Ristagno G; Yu T; Bisera J; Weil MH; Tang W Resuscitation; 2009 Nov; 80(11):1312-7. PubMed ID: 19720442 [TBL] [Abstract][Full Text] [Related]
14. [How to do: Cardioversion]. Lewalter T; Jilek C Dtsch Med Wochenschr; 2016 May; 141(10):706-8. PubMed ID: 27176064 [TBL] [Abstract][Full Text] [Related]
15. [Usage of a defibrillator]. Inomata M Nihon Rinsho; 2011 Apr; 69(4):695-8. PubMed ID: 21591425 [TBL] [Abstract][Full Text] [Related]
16. Variation in defibrillation modes after synchronized cardioversion: a potential hazard. Monsieurs KG; Coady EM Resuscitation; 1997 Aug; 35(1):37-9. PubMed ID: 9259059 [TBL] [Abstract][Full Text] [Related]
17. A comparison between monophasic and biphasic defibrillation for the cardioversion of persistent atrial fibrillation in patients with and without heart failure. Shelton RJ; Brown BD; Allinson A; Johnson T; Smales C; Jolly S; Cleland JG Int J Cardiol; 2011 Mar; 147(3):405-8. PubMed ID: 19861229 [TBL] [Abstract][Full Text] [Related]
18. Impedance-gradient electrode reduces skin irritation induced by transthoracic defibrillation. Meyer PF; Gadsby PD; Van Sickle D; Schoenlein WE; Foster KS; Graber GP Med Biol Eng Comput; 2005 Mar; 43(2):225-9. PubMed ID: 15865132 [TBL] [Abstract][Full Text] [Related]
19. Intra-atrial defibrillation of human atrial fibrillation. Santini M; Pandozi C; Gentilucci G; Villani M; Scianaro MC J Cardiovasc Electrophysiol; 1998 Aug; 9(8 Suppl):S170-6. PubMed ID: 9727694 [TBL] [Abstract][Full Text] [Related]
20. Evolution of the optimum bidirectional (+/- biphasic) wave for defibrillation. Geddes LA; Havel W Biomed Instrum Technol; 2000; 34(1):39-54. PubMed ID: 10690435 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]