These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

421 related articles for article (PubMed ID: 16275002)

  • 1. A simplified technique for implantation of left ventricular epicardial leads for biventricular re-synchronization using video-assisted thoracoscopy (VATS).
    Gabor S; Prenner G; Wasler A; Schweiger M; Tscheliessnigg KH; Smolle-Jüttner FM
    Eur J Cardiothorac Surg; 2005 Dec; 28(6):797-800. PubMed ID: 16275002
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Video-assisted thoracoscopic implantation of the left ventricular pacing lead for cardiac resynchronization therapy.
    Jutley RS; Waller DA; Loke I; Skehan D; Ng A; Stafford P; Chin D; Spyt TJ
    Pacing Clin Electrophysiol; 2008 Jul; 31(7):812-8. PubMed ID: 18684277
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Epicardial lead implantation techniques for biventricular pacing via left lateral mini-thoracotomy, video-assisted thoracoscopy, and robotic approach.
    Mair H; Jansens JL; Lattouf OM; Reichart B; Dabritz S
    Heart Surg Forum; 2003; 6(5):412-7. PubMed ID: 14721823
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Minimally invasive surgical implantation of left ventricular epicardial leads for ventricular resynchronization using video-assisted thoracoscopy.
    Fernández AL; García-Bengochea JB; Ledo R; Vega M; Amaro A; Alvarez J; Rubio J; Sierra J; Sánchez D
    Rev Esp Cardiol; 2004 Apr; 57(4):313-9. PubMed ID: 15104985
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Surgical epicardial left ventricular lead versus coronary sinus lead placement in biventricular pacing.
    Mair H; Sachweh J; Meuris B; Nollert G; Schmoeckel M; Schuetz A; Reichart B; Daebritz S
    Eur J Cardiothorac Surg; 2005 Feb; 27(2):235-42. PubMed ID: 15691676
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Nontraditional surgical approaches for implantation of pacemaker and cardioverter defibrillator systems in patients with limited venous access.
    Jaroszewski DE; Altemose GT; Scott LR; Srivasthan K; Devaleria PA; Lackey J; Arabia FA
    Ann Thorac Surg; 2009 Jul; 88(1):112-6. PubMed ID: 19559206
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Left heart atrial and ventricular epicardial pacing through a left lateral thoracotomy in children: a safe approach with excellent functional and cosmetic results.
    Dodge-Khatami A; Kadner A; Dave H; Rahn M; Prêtre R; Bauersfeld U
    Eur J Cardiothorac Surg; 2005 Oct; 28(4):541-5. PubMed ID: 16125947
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Epicardial left ventricular lead placement for cardiac resynchronization therapy: optimal pace site selection with pressure-volume loops.
    Dekker AL; Phelps B; Dijkman B; van der Nagel T; van der Veen FH; Geskes GG; Maessen JG
    J Thorac Cardiovasc Surg; 2004 Jun; 127(6):1641-7. PubMed ID: 15173718
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Totally epicardial cardiac re-synchronization therapy system implantation in patients with heart failure undergoing CABG--description of 3 cases.
    Bis J; Krejca M; Gościńska-Bis K; Szmagała P; Ulczok R; Bochenek A; Kargul W
    Kardiol Pol; 2007 Feb; 65(2):160-4; discussion 165. PubMed ID: 17366360
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Video-assisted thoracoscopic left ventricular pacing in patients with and without previous sternotomy.
    Nelson KE; Bates MG; Turley AJ; Linker NJ; Owens WA
    Ann Thorac Surg; 2013 Mar; 95(3):907-13. PubMed ID: 23313472
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Biventricular pacing for end-stage heart failure: early experience in surgical vs. transvenous left ventricular lead placement.
    Atoui R; Essebag V; Wu V; Ge Y; Auclair MH; Hadjis T; Shum-Tim D
    Interact Cardiovasc Thorac Surg; 2008 Oct; 7(5):839-44. PubMed ID: 18614553
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Adverse events with transvenous left ventricular pacing in patients with severe heart failure: early experience from a single centre.
    Valls-Bertault V; Mansourati J; Gilard M; Etienne Y; Munier S; Blanc JJ
    Europace; 2001 Jan; 3(1):60-3. PubMed ID: 11271954
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Efficacy of prophylactic epicardial pacing leads in children and young adults.
    Cohen MI; Rhodes LA; Spray TL; Gaynor JW
    Ann Thorac Surg; 2004 Jul; 78(1):197-202; discussion 202-3. PubMed ID: 15223427
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Long-term follow-up of biventricular pacing using a totally endocardial approach in patients with end-stage cardiac failure.
    Pasquié JL; Massin F; Macia JC; Gervasoni R; Bortone A; Cayla G; Grolleau R; Leclercq F
    Pacing Clin Electrophysiol; 2007 Jan; 30 Suppl 1():S31-3. PubMed ID: 17302712
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Subtotal innominate vein occlusion after unsuccessful pacemaker implantation for resynchronization therapy.
    Van Putte BP; Bakker PF
    Pacing Clin Electrophysiol; 2004 Nov; 27(11):1574-5. PubMed ID: 15546318
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A novel approach for endocardial resynchronization therapy: initial experience with transapical implantation of the left ventricular lead.
    Kassai I; Mihalcz A; Foldesi C; Kardos A; Szili-Torok T
    Heart Surg Forum; 2009 Jun; 12(3):E137-40. PubMed ID: 19546062
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Biventricular pacing--early experience.
    Pires R; Elvas L; Monteiro P; Cristóvão J; Antunes A; Ventura M; Costa M; Ermida P; Providência LA
    Rev Port Cardiol; 2001 Dec; 20(12):1235-9. PubMed ID: 11865683
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Left ventricular epicardial lead implantation via left minithoracotomy.
    Lehr EJ; Ye C; Wang S
    Thorac Cardiovasc Surg; 2009 Sep; 57(6):329-32. PubMed ID: 19707973
    [TBL] [Abstract][Full Text] [Related]  

  • 19. VATS-guided epicardial pacemaker implantation. Hand-sutured fixation of atrioventricular leads in an experimental setting.
    Furrer M; Fuhrer J; Altermatt HJ; Ris H; Mettler D; Althaus U; Carrel T
    Surg Endosc; 1997 Dec; 11(12):1167-70. PubMed ID: 9373287
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Endurance and performance of two different concepts for left ventricular stimulation with bipolar epicardial leads in long-term follow-up.
    Burger H; Kempfert J; van Linden A; Szalay Z; Schoenburg M; Walther T; Ziegelhoeffer T
    Thorac Cardiovasc Surg; 2012 Feb; 60(1):70-7. PubMed ID: 21789760
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 22.