These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

164 related articles for article (PubMed ID: 1627766)

  • 1. Pyrogenic reactions in patients receiving conventional, high-efficiency, or high-flux hemodialysis treatments with bicarbonate dialysate containing high concentrations of bacteria and endotoxin.
    Gordon SM; Oettinger CW; Bland LA; Oliver JC; Arduino MJ; Aguero SM; McAllister SK; Favero MS; Jarvis WR
    J Am Soc Nephrol; 1992 Mar; 2(9):1436-44. PubMed ID: 1627766
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A prospective study of pyrogenic reactions in hemodialysis patients using bicarbonate dialysis fluids filtered to remove bacteria and endotoxin.
    Pegues DA; Oettinger CW; Bland LA; Oliver JC; Arduino MJ; Aguero SM; McAllister SK; Gordon SM; Favero MS; Jarvis WR
    J Am Soc Nephrol; 1992 Oct; 3(4):1002-7. PubMed ID: 1450362
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Bacteria and endotoxin removal from bicarbonate dialysis fluids for use in conventional, high-efficiency, and high-flux hemodialysis.
    Oliver JC; Bland LA; Oettinger CW; Arduino MJ; Garrard M; Pegues DA; McAllister S; Moone T; Aguero S; Favero MS
    Artif Organs; 1992 Apr; 16(2):141-5. PubMed ID: 10078235
    [TBL] [Abstract][Full Text] [Related]  

  • 4. An outbreak of pyrogenic reactions in chronic hemodialysis patients associated with hemodialyzer reuse.
    Rudnick JR; Arduino MJ; Bland LA; Cusick L; McAllister SK; Aguero SM; Jarvis WR
    Artif Organs; 1995 Apr; 19(4):289-94. PubMed ID: 7598647
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Outbreak of pyrogenic reactions and gram-negative bacteremia in a hemodialysis center.
    Jackson BM; Beck-Sague CM; Bland LA; Arduino MJ; Meyer L; Jarvis WR
    Am J Nephrol; 1994; 14(2):85-9. PubMed ID: 8080011
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effects of incubation time and temperature on microbiologic sampling procedures for hemodialysis fluids.
    Arduino MJ; Bland LA; Aguero SM; Favero MS
    J Clin Microbiol; 1991 Jul; 29(7):1462-5. PubMed ID: 1885742
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [The level of endotoxins in hemodialysis water and dialysate].
    Skarupskiene I; Bumblyte IA; Kuzminskis V
    Medicina (Kaunas); 2007; 43 Suppl 1():81-4. PubMed ID: 17551282
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Microbiological and endotoxin assays of hemodialysis fluids.
    Bland LA
    Adv Ren Replace Ther; 1995 Jan; 2(1):70-9. PubMed ID: 7614339
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Endotoxin and bacterial contamination of dialysis center water and dialysate; a cross sectional survey.
    Harding GB; Klein E; Pass T; Wright R; Million C
    Int J Artif Organs; 1990 Jan; 13(1):39-43. PubMed ID: 2394493
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Microbial and endotoxin contamination in water and dialysate in the central United States.
    Klein E; Pass T; Harding GB; Wright R; Million C
    Artif Organs; 1990 Apr; 14(2):85-94. PubMed ID: 2350260
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Outbreak of gram-negative bacteremia and pyrogenic reactions in a hemodialysis center.
    Beck-Sague CM; Jarvis WR; Bland LA; Arduino MJ; Aguero SM; Verosic G
    Am J Nephrol; 1990; 10(5):397-403. PubMed ID: 2080790
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Contamination of dialysis water and dialysate. A survey of 30 centers.
    Bambauer R; Schauer M; Jung WK; Daum V; Vienken J
    ASAIO J; 1994; 40(4):1012-6. PubMed ID: 7858320
    [TBL] [Abstract][Full Text] [Related]  

  • 13. In vivo studies of dialysis-related endotoxemia and bacteremia.
    Bernick JJ; Port FK; Favero MS
    Nephron; 1981; 27(6):307-12. PubMed ID: 7266719
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Dialysate and biocompatibility in hemodialysis].
    Berland Y
    Nephrologie; 1998; 19(6):329-34. PubMed ID: 9836194
    [TBL] [Abstract][Full Text] [Related]  

  • 15. High-flux dialyzers, backfiltration, and dialysis fluid quality.
    Schiffl H
    Semin Dial; 2011; 24(1):1-4. PubMed ID: 21299628
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [High-efficiency membranes and the dialysis solution].
    Agliata S; Airoldi G; Baroni A; Boschetti M; Schweiger K; Fortina F; Ragazzoni E; Cavagnino A
    Minerva Urol Nefrol; 1990; 42(1):39-42. PubMed ID: 2389221
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Transmembrane passage of cytokine-inducing bacterial products across new and reprocessed polysulfone dialyzers.
    Sundaram S; Barrett TW; Meyer KB; Perrella C; Neto MC; King AJ; Pereira BJ
    J Am Soc Nephrol; 1996 Oct; 7(10):2183-91. PubMed ID: 8915979
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Pyrogenic reactions associated with the reuse of disposable hollow-fiber hemodialyzers.
    Gordon SM; Tipple M; Bland LA; Jarvis WR
    JAMA; 1988 Oct; 260(14):2077-81. PubMed ID: 3418872
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Chronic haemodialysis with bicarbonate dialysate. Technical and clinical aspects.
    Leunissen KM; Claessens PJ; Mooy JM; van Hooff JP; Shaldon S
    Blood Purif; 1990; 8(6):347-58. PubMed ID: 2093332
    [TBL] [Abstract][Full Text] [Related]  

  • 20. High-permeable membranes and hypersensitivity-like reactions: role of dialysis fluid contamination.
    Bigazzi R; Atti M; Baldari G
    Blood Purif; 1990; 8(4):190-8. PubMed ID: 2085427
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.