These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
69 related articles for article (PubMed ID: 16281725)
41. Tibioperoneal Short Circuiting for Stump Neuroma Pain in Amputees: Revival of an Old Technique. Boroumand MR; Schulz D; Uhl E; Krishnan KG World Neurosurg; 2015 Sep; 84(3):681-7. PubMed ID: 25937355 [TBL] [Abstract][Full Text] [Related]
42. Hanging stump prosthesis without socket for bad above-knee stumps. Chand N; Srivastava RK; Maish AR Prosthet Orthot Int; 1985 Dec; 9(3):154-6. PubMed ID: 4088844 [TBL] [Abstract][Full Text] [Related]
43. The use of an adjustable electrode housing unit to compare electrode alignment and contact variation with myoelectric prosthesis functionality: A pilot study. Head JS; Howard D; Hutchins SW; Kenney L; Heath GH; Aksenov AY Prosthet Orthot Int; 2016 Feb; 40(1):123-8. PubMed ID: 25134531 [TBL] [Abstract][Full Text] [Related]
44. [Comparative study of the volume difference vs. healthy limb, morphological and population description in transfemoral amputees]. Mendoza-Cruz F; Rodríguez-Reyes G; Galván Duque-Gastélum C; Alvarez-Camacho M Rev Invest Clin; 2014 Jul; 66 Suppl 1():S85-93. PubMed ID: 25264803 [TBL] [Abstract][Full Text] [Related]
45. Calibration problems encountered while monitoring stump/socket interface pressures with force sensing resistors: techniques adopted to minimise inaccuracies. Buis AW; Convery P Prosthet Orthot Int; 1997 Dec; 21(3):179-82. PubMed ID: 9453089 [TBL] [Abstract][Full Text] [Related]
46. Outcome of fitting an ICEROSS prosthesis: views of trans-tibial amputees. Datta D; Vaidya SK; Howitt J; Gopalan L Prosthet Orthot Int; 1996 Aug; 20(2):111-5. PubMed ID: 8876004 [TBL] [Abstract][Full Text] [Related]
48. Dynamic alignment of transtibial prostheses through visualization of socket reaction moments. Kobayashi T; Orendurff MS; Boone DA Prosthet Orthot Int; 2015 Dec; 39(6):512-6. PubMed ID: 25121726 [TBL] [Abstract][Full Text] [Related]
49. Bacteria on stumps of amputees and the effect of antiseptics. Köhler P; Lindh L; Björklind A Prosthet Orthot Int; 1989 Dec; 13(3):149-51. PubMed ID: 2514413 [TBL] [Abstract][Full Text] [Related]
50. Twenty-one months' experience with the PF-modified CIR casting system for trans-tibial prostheses. Jivacate T; Devakula ML; Tipaya B; Yesuwarn T Prosthet Orthot Int; 2011 Mar; 35(1):70-5. PubMed ID: 21515891 [TBL] [Abstract][Full Text] [Related]
51. Validation of spiral CT and optical surface scanning for lower limb stump volumetry. Smith KE; Commean PK; Bhatia G; Vannier MW Prosthet Orthot Int; 1995 Aug; 19(2):97-107. PubMed ID: 8570386 [TBL] [Abstract][Full Text] [Related]
55. Preliminary experiences with the CIR casting system for transtibial prosthetic sockets. Thanh NH; Poetsma PA; Jensen JS Prosthet Orthot Int; 2009 Jun; 33(2):130-4. PubMed ID: 19367516 [TBL] [Abstract][Full Text] [Related]
56. CAD/CAM evaluation of the fit of trans-tibial sockets for trans-tibial amputation stumps. Isozaki K; Hosoda M; Masuda T; Morita S J Med Dent Sci; 2006 Mar; 53(1):51-6. PubMed ID: 16722145 [TBL] [Abstract][Full Text] [Related]
57. Relaxed versus activated stump muscles during casting for trans-tibial prostheses. Lilja M; Johansson S; Oberg T Prosthet Orthot Int; 1999 Apr; 23(1):13-20. PubMed ID: 10355639 [TBL] [Abstract][Full Text] [Related]
58. Fitting very short finger stumps with silicone prosthesis: a nonsurgical method. Leow ME; Chong AK; Peng YP; Pho RW Prosthet Orthot Int; 2013 Oct; 37(5):415-20. PubMed ID: 23295897 [TBL] [Abstract][Full Text] [Related]
59. Literature review of the possible advantages of silicon liner socket use in trans-tibial prostheses. Baars EC; Geertzen JH Prosthet Orthot Int; 2005 Apr; 29(1):27-37. PubMed ID: 16180375 [TBL] [Abstract][Full Text] [Related]