These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

226 related articles for article (PubMed ID: 16281752)

  • 1. [Selective intubation through a rigid bronchoscope].
    de la Linde CM; López MI; Ortiz JM; Pulido S
    Rev Esp Anestesiol Reanim; 2005 Oct; 52(8):509-11. PubMed ID: 16281752
    [No Abstract]   [Full Text] [Related]  

  • 2. [Right main bronchus tumoral obstruction during left pneumonectomy].
    Markowicz P; Fossier T
    Ann Fr Anesth Reanim; 2006 Jun; 25(6):648-51. PubMed ID: 16600563
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Case report: separation from cardiopulmonary bypass with a rigid bronchoscope airway after hemoptysis and bronchial impaction with clot.
    Neuburger PJ; Galloway AC; Zervos MD; Kanchuger MS
    Anesth Analg; 2012 Jan; 114(1):89-92. PubMed ID: 22034489
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Intraoperative airway obstruction due to dissection of a reinforced endotracheal tube in a prone patient.
    Rajkumar A; Bajekal R
    J Neurosurg Anesthesiol; 2011 Oct; 23(4):377. PubMed ID: 21876451
    [No Abstract]   [Full Text] [Related]  

  • 5. Anesthetic management of the complications of previously undiagnosed ingested foreign body in a pediatric patient.
    Somerville NS; Mearns C; Chin C; Blaney S; Anderson D
    Paediatr Anaesth; 2004 Dec; 14(12):1023-6. PubMed ID: 15601354
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Internal blistering of armored latex endotracheal tubes].
    Rouco Martínez I; Catalá Puigbó E; Baxarias Gascón P
    Rev Esp Anestesiol Reanim; 1984; 31(5):208-10. PubMed ID: 6505343
    [No Abstract]   [Full Text] [Related]  

  • 7. Impacted gum-elastic bougie in an endotracheal tube after successful intubation of a difficult airway.
    Arya VK; Makker S; Bedi SP
    J Clin Anesth; 2007 Nov; 19(7):566. PubMed ID: 18063220
    [No Abstract]   [Full Text] [Related]  

  • 8. [Case report: lumen obstruction with a Magill tube].
    Deller A; Weichel T
    Anasth Intensivther Notfallmed; 1990 Aug; 25(4):293-4. PubMed ID: 2221303
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Tracheal tube obstruction mimicking a bronchospasm].
    Hugot P; Aguillon D; Musellec H; Breitel D; Gentili M
    Ann Fr Anesth Reanim; 2012 May; 31(5):488-90. PubMed ID: 22513179
    [No Abstract]   [Full Text] [Related]  

  • 10. [Obstruction of an reinforced endotracheal tube due to dissection of internal tube wall during total intravenous anesthesia].
    Tose R; Kubota T; Hirota K; Sakai T; Ishihara H; Matsuki A
    Masui; 2003 Nov; 52(11):1218-20. PubMed ID: 14661571
    [TBL] [Abstract][Full Text] [Related]  

  • 11. An unusual foreign body obstructing endotracheal tube connector.
    Roy B; Barman B; Dutta C; Basu SM
    J Indian Med Assoc; 1995 Sep; 93(9):358. PubMed ID: 8648160
    [No Abstract]   [Full Text] [Related]  

  • 12. Airway topical anesthesia using a rigid fiberoptic stylet in children with difficult airways.
    Xue FS; He N; Luo MP; Liao X
    Paediatr Anaesth; 2009 Feb; 19(2):187-9. PubMed ID: 19207916
    [No Abstract]   [Full Text] [Related]  

  • 13. The dissection of reinforced endotracheal tube internal wall causing intraoperative airway obstruction under general anesthesia: case report.
    Mercanoglu E; Topuz D; Kaya N
    Braz J Anesthesiol; 2013; 63(4):372-4. PubMed ID: 23931255
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Emergency airway management of an extremely low-birth-weight infant with subglottic stenosis.
    Umegaki T; Asai T; Kojima K; Murao K; Shingu K
    Paediatr Anaesth; 2008 Oct; 18(10):991-2. PubMed ID: 18811843
    [No Abstract]   [Full Text] [Related]  

  • 15. Airway obstruction by an unexpected equipment damage.
    Schober P; Loer SA; Schwarte LA
    J Clin Anesth; 2016 Aug; 32():59-61. PubMed ID: 27290946
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A rare cause of endotracheal tube obstruction: a broken stylet going unnoticed--a case report.
    Sharma A; Jain V; Mitra JK; Prabhakar H
    Middle East J Anaesthesiol; 2008 Feb; 19(4):909-11. PubMed ID: 18630777
    [No Abstract]   [Full Text] [Related]  

  • 17. [Intraoperative acute airway obstruction due to the damage of a reinforced endotracheal tube in thyroidectomy].
    Ida M; Kuzumoto N; Nakayama K; Krimoto K; Kamiya T; Iwata M; Shimomura T
    Masui; 2014 Oct; 63(10):1128-30. PubMed ID: 25693343
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Flexometalic endotraqueal tube burn in laser surgery.
    Sanchez D; Serrano C; León MC
    Rev Esp Anestesiol Reanim; 2017; 64(6):362-363. PubMed ID: 28385293
    [No Abstract]   [Full Text] [Related]  

  • 19. Obstruction of endotracheal tube; a manufacturing error.
    Hajimohammadi F; Taheri A; Eghtesadi-Araghi P
    Middle East J Anaesthesiol; 2009 Jun; 20(2):303-5. PubMed ID: 19583085
    [No Abstract]   [Full Text] [Related]  

  • 20. Tracheal laceration after the use of an airway exchange catheter for double-lumen tube placement.
    Thomas V; Neustein SM
    J Cardiothorac Vasc Anesth; 2007 Oct; 21(5):718-9. PubMed ID: 17905282
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 12.