BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

137 related articles for article (PubMed ID: 16283270)

  • 1. Capillary-channeled polymer (C-CP) fibers as a stationary phase in microbore high-performance liquid chromatography columns.
    Stanelle RD; Mignanelli M; Brown P; Marcus RK
    Anal Bioanal Chem; 2006 Jan; 384(1):250-8. PubMed ID: 16283270
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Microbore polypropylene capillary channeled polymer (C-CP) fiber columns for rapid reversed-phase HPLC of proteins.
    Randunu KM; Marcus RK
    Anal Bioanal Chem; 2012 Aug; 404(3):721-9. PubMed ID: 22736228
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Dynamic evaluation of polypropylene capillary-channeled fibers as a stationary phase in high-performance liquid chromatography.
    Randunu KM; Dimartino S; Marcus RK
    J Sep Sci; 2012 Dec; 35(23):3270-80. PubMed ID: 23109248
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Characterization of capillary-channeled polymer fiber stationary phases for high-performance liquid chromatography protein separations: Comparative analysis with a packed-bed column.
    Nelson DM; Marcus RK
    Anal Chem; 2006 Dec; 78(24):8462-71. PubMed ID: 17165840
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Capillary-channeled polymer fibers as stationary phases in liquid chromatography separations.
    Marcus RK; Davis WC; Knippel BC; LaMotte L; Hill TA; Perahia D; Jenkins JD
    J Chromatogr A; 2003 Jan; 986(1):17-31. PubMed ID: 12585319
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Hydrodynamic flow in capillary-channel fiber columns for liquid chromatography.
    Stanelle RD; Sander LC; Marcus RK
    J Chromatogr A; 2005 Dec; 1100(1):68-75. PubMed ID: 16194542
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Initial evaluation of protein throughput and yield characteristics on nylon 6 capillary-channeled polymer (C-CP) fiber stationary phases by frontal analysis.
    Randunu KM; Marcus RK
    Biotechnol Prog; 2013; 29(5):1222-9. PubMed ID: 23804494
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Nylon-6 capillary-channeled polymer (C-CP) fibers as a hydrophobic interaction chromatography stationary phase for the separation of proteins.
    Stanelle RD; Marcus RK
    Anal Bioanal Chem; 2009 Jan; 393(1):273-81. PubMed ID: 18958449
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A novel stationary phase: capillary-channeled polymer (C-CP) fibers for HPLC separations of proteins.
    Nelson DK; Marcus RK
    J Chromatogr Sci; 2003 Oct; 41(9):475-9. PubMed ID: 14596784
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Biotin-functionalized poly(ethylene terephthalate) capillary-channeled polymer fibers as HPLC stationary phase for affinity chromatography.
    Jiang L; Marcus RK
    Anal Bioanal Chem; 2015 Jan; 407(3):939-51. PubMed ID: 25410640
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Roles of interstitial fraction and load conditions on the dynamic binding capacity of proteins on capillary-channeled polymer fiber columns.
    Wang Z; Marcus RK
    Biotechnol Prog; 2015; 31(1):97-109. PubMed ID: 25378292
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Polypropylene capillary-channeled polymer fiber column as the second dimension in a comprehensive two-dimensional RP × RP analysis of a mixture of intact proteins.
    Wang L; Marcus RK
    Anal Bioanal Chem; 2020 May; 412(12):2963-2979. PubMed ID: 32128643
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of analytical protein separation characteristics for three amine-based capillary-channeled polymer (C-CP) stationary phases.
    Jiang L; Marcus RK
    Anal Bioanal Chem; 2016 Feb; 408(5):1373-83. PubMed ID: 26345444
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparative analysis of trilobal capillary-channeled polymer fiber columns with superficially porous and monolithic phases toward reversed-phase protein separations.
    Billotto LS; Marcus RK
    J Sep Sci; 2022 Oct; 45(20):3811-3826. PubMed ID: 35986632
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Performance of monolithic silica capillary columns with increased phase ratios and small-sized domains.
    Hara T; Kobayashi H; Ikegami T; Nakanishi K; Tanaka N
    Anal Chem; 2006 Nov; 78(22):7632-42. PubMed ID: 17105153
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of bed compression on high-performance liquid chromatography columns with gigaporous polymeric packings.
    Freitag R; Frey D; Horváth C
    J Chromatogr A; 1994 Dec; 686(2):165-77. PubMed ID: 7881529
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Theoretical and experimental impact of the bed aspect ratio on the axial dispersion coefficient of columns packed with 2.5 μm particles.
    Gritti F; Guiochon G
    J Chromatogr A; 2012 Nov; 1262():107-21. PubMed ID: 23010248
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Determination of pore size distributions in capillary-channeled polymer fiber stationary phases by inverse size-exclusion chromatography and implications for fast protein separations.
    Wang Z; Marcus RK
    J Chromatogr A; 2014 Jul; 1351():82-9. PubMed ID: 24877979
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Potential for ultrafast protein separations with capillary-channeled polymer (C-CP) fiber columns.
    Nelson DM; Marcus RK
    Protein Pept Lett; 2006; 13(1):95-9. PubMed ID: 16454677
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Ultrahigh-pressure liquid chromatography using a 1-mm id column packed with 1.5-microm porous particles.
    Anspach JA; Maloney TD; Colón LA
    J Sep Sci; 2007 May; 30(8):1207-13. PubMed ID: 17595956
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.