These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

115 related articles for article (PubMed ID: 16293012)

  • 21. [Research on the modeling of biological valves poppet].
    Yuan Q; Zhou Y; Cong H
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2005 Dec; 22(6):1197-9. PubMed ID: 16422098
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [The research on computer modeling for artificial bio-valve].
    Song W; Zheng J; Zheng B
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2002 Dec; 19(4):579-82. PubMed ID: 12561352
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Comparison of the hemodynamic and thrombogenic performance of two bileaflet mechanical heart valves using a CFD/FSI model.
    Dumont K; Vierendeels J; Kaminsky R; van Nooten G; Verdonck P; Bluestein D
    J Biomech Eng; 2007 Aug; 129(4):558-65. PubMed ID: 17655477
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Fundamental mechanics of aortic heart valve closure.
    Hose DR; Narracott AJ; Penrose JM; Baguley D; Jones IP; Lawford PV
    J Biomech; 2006; 39(5):958-67. PubMed ID: 16488234
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Physiologically-based testing system for the mechanical characterization of prosthetic vein valves.
    Rittgers SE; Oberdier MT; Pottala S
    Biomed Eng Online; 2007 Jul; 6():29. PubMed ID: 17629916
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Hydraulic functional characterisation of aortic mechanical heart valve prostheses through lumped-parameter modelling.
    Fiore GB; Grigioni M; Daniele C; D'Avenio G; Barbaro V; Fumero R
    J Biomech; 2002 Oct; 35(10):1427-32. PubMed ID: 12231289
    [TBL] [Abstract][Full Text] [Related]  

  • 27. The effect of pathologic venous valve on neighboring valves: fluid-structure interactions modeling.
    Soifer E; Weiss D; Marom G; Einav S
    Med Biol Eng Comput; 2017 Jun; 55(6):991-999. PubMed ID: 27663560
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Virtual medical devices.
    Garnsworthy J
    Med Device Technol; 2002 Dec; 13(10):24-6. PubMed ID: 12575525
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Prosthetic heart valves: Objective Performance Criteria versus randomized clinical trial.
    Grunkemeier GL; Jin R; Starr A
    Ann Thorac Surg; 2006 Sep; 82(3):776-80. PubMed ID: 16928482
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Time-resolved PIV technique for high temporal resolution measurement of mechanical prosthetic aortic valve fluid dynamics.
    Kaminsky R; Morbiducci U; Rossi M; Scalise L; Verdonck P; Grigioni M
    Int J Artif Organs; 2007 Feb; 30(2):153-62. PubMed ID: 17377910
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [Home monitoring of patients after prosthetic valve replacement. Early detection of valve dysfunction].
    Fritzsche D; Eitz T; Horstkotte D; Körfer R
    Herz; 2007 Sep; 32(6):491-8. PubMed ID: 17882374
    [TBL] [Abstract][Full Text] [Related]  

  • 32. An experimentally derived stress resultant shell model for heart valve dynamic simulations.
    Kim H; Chandran KB; Sacks MS; Lu J
    Ann Biomed Eng; 2007 Jan; 35(1):30-44. PubMed ID: 17089074
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Computational fluid dynamics simulation of transcatheter aortic valve degeneration.
    Dwyer HA; Matthews PB; Azadani A; Jaussaud N; Ge L; Guy TS; Tseng EE
    Interact Cardiovasc Thorac Surg; 2009 Aug; 9(2):301-8. PubMed ID: 19414489
    [TBL] [Abstract][Full Text] [Related]  

  • 34. In-vivo experience with the Triflo trileaflet mechanical heart valve.
    Gallegos RP; Rivard AL; Suwan PT; Black S; Bertog S; Steinseifer U; Armien A; Lahti M; Bianco RW
    J Heart Valve Dis; 2006 Nov; 15(6):791-9. PubMed ID: 17152787
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Methods of design, simulation, and control for the development of new VAD/TAH concepts.
    Finocchiaro T; Heinke S; Behbahani M; Lessmann M; Laumen M; Steinseifer U; Schmitz-Rode T; Leonhardt S; Behr M; Hameyer K
    Biomed Tech (Berl); 2009 Oct; 54(5):269-81. PubMed ID: 19807290
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Numerical dye washout method as a tool for characterizing the heart valve flow: study of three standard mechanical heart valves.
    Goubergrits L; Kertzscher U; Affeld K; Petz C; Stalling D; Hege HC
    ASAIO J; 2008; 54(1):50-7. PubMed ID: 18204316
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Automated assembly and testing in medical device production.
    Jones M
    Med Device Technol; 2002 Oct; 13(8):38-40. PubMed ID: 12416333
    [No Abstract]   [Full Text] [Related]  

  • 38. Mistake proofing and redundancy in machine validation.
    Blake N
    Med Device Technol; 2003; 14(1):42-5. PubMed ID: 12974126
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Development of a sheep model of atrial fibrillation for preclinical prosthetic valve testing.
    Rivard AL; Suwan PT; Imaninaini K; Gallegos RP; Bianco RW
    J Heart Valve Dis; 2007 May; 16(3):314-23. PubMed ID: 17578054
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Numerical analysis on the hemodynamics and leaflet dynamics in a bileaflet mechanical heart valve using a fluid-structure interaction method.
    Choi CR; Kim CN
    ASAIO J; 2009; 55(5):428-37. PubMed ID: 19730001
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.