434 related articles for article (PubMed ID: 16293101)
21. Future materials for foot surgery.
Latour RA
Clin Podiatr Med Surg; 1995 Jul; 12(3):519-44. PubMed ID: 7553538
[TBL] [Abstract][Full Text] [Related]
22. Optimization of Cr content of metastable β-type Ti-Cr alloys with changeable Young's modulus for spinal fixation applications.
Zhao X; Niinomi M; Nakai M; Hieda J; Ishimoto T; Nakano T
Acta Biomater; 2012 Jul; 8(6):2392-400. PubMed ID: 22342893
[TBL] [Abstract][Full Text] [Related]
23. Development of new metallic alloys for biomedical applications.
Niinomi M; Nakai M; Hieda J
Acta Biomater; 2012 Nov; 8(11):3888-903. PubMed ID: 22765961
[TBL] [Abstract][Full Text] [Related]
24. Phases in titanium alloys.
Williams D
Med Device Technol; 2005 Oct; 16(8):9-11. PubMed ID: 16355962
[TBL] [Abstract][Full Text] [Related]
25. Surface mechanical properties, corrosion resistance, and cytocompatibility of nitrogen plasma-implanted nickel-titanium alloys: a comparative study with commonly used medical grade materials.
Yeung KW; Poon RW; Chu PK; Chung CY; Liu XY; Lu WW; Chan D; Chan SC; Luk KD; Cheung KM
J Biomed Mater Res A; 2007 Aug; 82(2):403-14. PubMed ID: 17295246
[TBL] [Abstract][Full Text] [Related]
26. Electrochemical behavior of near-beta titanium biomedical alloys in phosphate buffer saline solution.
Dalmau A; Guiñón Pina V; Devesa F; Amigó V; Igual Muñoz A
Mater Sci Eng C Mater Biol Appl; 2015 Mar; 48():55-62. PubMed ID: 25579896
[TBL] [Abstract][Full Text] [Related]
27. Nanocrystalline β-Ti alloy with high hardness, low Young's modulus and excellent in vitro biocompatibility for biomedical applications.
Xie KY; Wang Y; Zhao Y; Chang L; Wang G; Chen Z; Cao Y; Liao X; Lavernia EJ; Valiev RZ; Sarrafpour B; Zoellner H; Ringer SP
Mater Sci Eng C Mater Biol Appl; 2013 Aug; 33(6):3530-6. PubMed ID: 23706243
[TBL] [Abstract][Full Text] [Related]
28. Corrosion resistance, surface mechanical properties, and cytocompatibility of plasma immersion ion implantation-treated nickel-titanium shape memory alloys.
Yeung KW; Poon RW; Liu XY; Ho JP; Chung CY; Chu PK; Lu WW; Chan D; Cheung KM
J Biomed Mater Res A; 2005 Nov; 75(2):256-67. PubMed ID: 16078209
[TBL] [Abstract][Full Text] [Related]
29. On the nature of the biocompatibility and on medical applications of NiTi shape memory and superelastic alloys.
Shabalovskaya SA
Biomed Mater Eng; 1996; 6(4):267-89. PubMed ID: 8980835
[TBL] [Abstract][Full Text] [Related]
30. Titanium alloys for fracture fixation implants.
Disegi JA
Injury; 2000 Dec; 31 Suppl 4():14-7. PubMed ID: 11270074
[TBL] [Abstract][Full Text] [Related]
31. Production, microstructural characterization and mechanical properties of as-cast Ti-10Mo-xNb alloys.
Gabriel SB; Nunes CA; Soares Gde A
Artif Organs; 2008 Apr; 32(4):299-304. PubMed ID: 18370944
[TBL] [Abstract][Full Text] [Related]
32. Cytocompatibility of a free machining titanium alloy containing lanthanum.
Feyerabend F; Siemers C; Willumeit R; Rösler J
J Biomed Mater Res A; 2009 Sep; 90(3):931-9. PubMed ID: 18646202
[TBL] [Abstract][Full Text] [Related]
33. Deformation-induced ω phase in modified Ti-29Nb-13Ta-4.6Zr alloy by Cr addition.
Li Q; Niinomi M; Hieda J; Nakai M; Cho K
Acta Biomater; 2013 Aug; 9(8):8027-35. PubMed ID: 23624220
[TBL] [Abstract][Full Text] [Related]
34. Initial exploration of Ti-Ta, Ti-Ta-Ir and Ti-Ir alloys: Candidate materials for coronary stents.
O'Brien B; Stinson J; Carroll W
Acta Biomater; 2008 Sep; 4(5):1553-9. PubMed ID: 18396116
[TBL] [Abstract][Full Text] [Related]
35. Mechanical properties of low modulus beta titanium alloys designed from the electronic approach.
Laheurte P; Prima F; Eberhardt A; Gloriant T; Wary M; Patoor E
J Mech Behav Biomed Mater; 2010 Nov; 3(8):565-73. PubMed ID: 20826362
[TBL] [Abstract][Full Text] [Related]
36. Relationship between various deformation-induced products and mechanical properties in metastable Ti-30Zr-Mo alloys for biomedical applications.
Zhao X; Niinomi M; Nakai M
J Mech Behav Biomed Mater; 2011 Nov; 4(8):2009-16. PubMed ID: 22098900
[TBL] [Abstract][Full Text] [Related]
37. Heterogeneous structure and mechanical hardness of biomedical β-type Ti-29Nb-13Ta-4.6Zr subjected to high-pressure torsion.
Yilmazer H; Niinomi M; Nakai M; Hieda J; Todaka Y; Akahori T; Miyazaki T
J Mech Behav Biomed Mater; 2012 Jun; 10():235-45. PubMed ID: 22520435
[TBL] [Abstract][Full Text] [Related]
38. Magnesium and its alloys as orthopedic biomaterials: a review.
Staiger MP; Pietak AM; Huadmai J; Dias G
Biomaterials; 2006 Mar; 27(9):1728-34. PubMed ID: 16246414
[TBL] [Abstract][Full Text] [Related]
39. Selfprotective smart orthopedic implants.
Parvizi J; Antoci V; Hickok NJ; Shapiro IM
Expert Rev Med Devices; 2007 Jan; 4(1):55-64. PubMed ID: 17187471
[TBL] [Abstract][Full Text] [Related]
40. Design of new titanium alloys for orthopaedic applications.
Guillemot F; Prima F; Bareille R; Gordin D; Gloriant T; Porté-Durrieu MC; Ansel D; Baquey Ch
Med Biol Eng Comput; 2004 Jan; 42(1):137-41. PubMed ID: 14977235
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]