BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

149 related articles for article (PubMed ID: 16294139)

  • 1. Biomechanics of olive wire positioning and tensioning characteristics.
    Antoci V; Voor MJ; Antoci V; Roberts CS
    J Pediatr Orthop; 2005; 25(6):798-803. PubMed ID: 16294139
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Transfixion wire positioning within the bone: an option to control proximal tibia external fixation stiffness.
    Antoci V; Raney EM; Antoci V; Voor MJ; Roberts CS
    J Pediatr Orthop; 2006; 26(4):466-70. PubMed ID: 16791063
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The effect of transfixion wire number and spacing between two levels of fixation on the stiffness of proximal tibial external fixation.
    Antoci V; Roberts CS; Antoci V; Voor MJ
    J Orthop Trauma; 2005 Mar; 19(3):180-6. PubMed ID: 15758671
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of wire tension on stiffness of tensioned fine wires in external fixation: a mechanical study.
    Antoci V; Voor MJ; Antoci V; Roberts CS
    Am J Orthop (Belle Mead NJ); 2007 Sep; 36(9):473-6. PubMed ID: 17948150
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The effect of wire plane tilt and olive wires on proximal tibia fracture fragment stability and fracture site motion.
    Voor MJ; Antoci V; Antoci V; Roberts CS
    J Biomech; 2005 Mar; 38(3):537-41. PubMed ID: 15652552
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The effect of transfixion wire crossing angle on the stiffness of fine wire external fixation: a biomechanical study.
    Roberts CS; Antoci V; Antoci V; Voor MJ
    Injury; 2005 Sep; 36(9):1107-12. PubMed ID: 16098336
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of alternate and simultaneous tensioning of wires in a single-ring fixator construct.
    Ryan S; Ehrhart N; Zuehlsdorff K; James S
    Vet Surg; 2009 Jan; 38(1):96-103. PubMed ID: 19152623
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Axial characteristics of circular external skeletal fixator single ring constructs.
    Lewis DD; Bronson DG; Cross AR; Welch RD; Kubilis PS
    Vet Surg; 2001; 30(4):386-94. PubMed ID: 11443601
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Mechanical performance of Ilizarov circular external fixators in comparison with other external fixators.
    Podolsky A; Chao EY
    Clin Orthop Relat Res; 1993 Aug; (293):61-70. PubMed ID: 8339510
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Mechanical effect of posterior wire or half-pin configuration on stabilization utilizing a model of circular external fixation of the foot.
    Rocchio TM; Younes MB; Bronson DG; Birch JG; Samchukov ML
    Foot Ankle Int; 2004 Mar; 25(3):136-43. PubMed ID: 15006334
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A biomechanical evaluation of three drop wire configurations.
    Arango J; Lewis DD; Hudson CC; Horodyski M
    Vet Surg; 2013 Aug; 42(6):669-77. PubMed ID: 23796078
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The effects of different wire and screw combinations on the stiffness of a hybrid external fixator.
    Yang L; Saleeh M; Nayagam S
    Proc Inst Mech Eng H; 2000; 214(6):669-76. PubMed ID: 11201414
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Hybrid external fixation of distal tibial fractures: new strategy to place pins and wires without penetrating the anterior compartment.
    Oh JK; Lee JJ; Jung DY; Kim BJ; Oh CW
    Arch Orthop Trauma Surg; 2004 Oct; 124(8):542-6. PubMed ID: 15340748
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Mechanical considerations in using tensioned wires in a transosseous external fixation system.
    Aronson J; Harp JH
    Clin Orthop Relat Res; 1992 Jul; (280):23-9. PubMed ID: 1611749
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Biomechanics of the Ilizarov external fixator.
    Kummer FJ
    Bull Hosp Jt Dis Orthop Inst; 1989; 49(2):140-7. PubMed ID: 2557936
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Tensioning technique and fixator stability of a circular external fixator with threaded fine wires.
    Rickman M; Saleh M; Yang L
    J Biomech; 2006; 39(3):544-50. PubMed ID: 16389095
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The effect of wire configuration on the stability of the Ilizarov external fixator.
    Orbay GL; Frankel VH; Kummer FJ
    Clin Orthop Relat Res; 1992 Jun; (279):299-302. PubMed ID: 1600668
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Axial stiffness and ring deformation of complete and incomplete single ring circular external skeletal fixator constructs.
    Hudson CC; Lewis DD; Cross AR; Horodyski M; Banks SA; Pozzi A
    Am J Vet Res; 2012 Dec; 73(12):2021-8. PubMed ID: 23176434
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Biomechanical Considerations in Foot and Ankle Circular External Fixation: Maintenance of Wire Tension.
    Samchukov ML; Clifford CE; McCann KM; Cherkashin AM; Hutchinson B; Pierce WA
    Clin Podiatr Med Surg; 2018 Oct; 35(4):443-455. PubMed ID: 30223952
    [TBL] [Abstract][Full Text] [Related]  

  • 20. An assessment of the fixin tplo jig to generate effective compression using a transverse fracture model.
    Ferringo CRA; Diggs G; Lewis DD; Banks SA
    PLoS One; 2023; 18(10):e0286937. PubMed ID: 37831702
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.