348 related articles for article (PubMed ID: 16294548)
1. [Five years experience with non-pulsatile flow].
Grinda JM; Bricourt MO; Salvi S; Jouan J; Guillemain R; Deloche A; Fabiani JN
Arch Mal Coeur Vaiss; 2005 Oct; 98(10):1008-12. PubMed ID: 16294548
[TBL] [Abstract][Full Text] [Related]
2. [The DeBakey VAD axial flow pump: first clinical experience with a new generation of implantable, nonpulsatile blood pumps for long-term support prior to transplantation].
Wieselthaler GM; Schima H; Lassnigg A; Pacher R; Ovsenk T; Laufer G; Noon GP; DeBakey ME; Wolner E
Wien Klin Wochenschr; 1999 Sep; 111(16):629-35. PubMed ID: 10510840
[TBL] [Abstract][Full Text] [Related]
3. Mechanical circulatory support therapy as a bridge to transplant or recovery (new advances).
Kirklin JK; Holman WL
Curr Opin Cardiol; 2006 Mar; 21(2):120-6. PubMed ID: 16470148
[TBL] [Abstract][Full Text] [Related]
4. [Left monoventricular assistance with DeBakey VAD continuous flow pump: initial clinical Italian experience].
Lanfranconi M; Russo C; Ribera E; Colombo T; Bruschi G; Agati S; Vitali E
Ital Heart J Suppl; 2001 Jun; 2(6):653-8. PubMed ID: 11460840
[TBL] [Abstract][Full Text] [Related]
5. Effects of centrifugal, axial, and pulsatile left ventricular assist device support on end-organ function in heart failure patients.
Kamdar F; Boyle A; Liao K; Colvin-adams M; Joyce L; John R
J Heart Lung Transplant; 2009 Apr; 28(4):352-9. PubMed ID: 19332262
[TBL] [Abstract][Full Text] [Related]
6. [Terminal cardiac failure. Circulatory assist devices].
Duveau D; Baron O
Arch Mal Coeur Vaiss; 1996 Nov; 89 Spec No 6():51-4. PubMed ID: 9092428
[TBL] [Abstract][Full Text] [Related]
7. Clinical outcome and bridge to transplant rate of left ventricular assist device recipient patients: comparison between continuous-flow and pulsatile-flow devices.
Garatti A; Bruschi G; Colombo T; Russo C; Lanfranconi M; Milazzo F; Frigerio M; Vitali E
Eur J Cardiothorac Surg; 2008 Aug; 34(2):275-80; discussion 280. PubMed ID: 18375138
[TBL] [Abstract][Full Text] [Related]
8. [Circulatory support with the mechanical heart, "HeartMate"].
Sander Jensen KM; Aldershvile J; Boesgaard S; Hansen PB; Kjersem AM; Kolbye A; Mortensen SA; Nielsen KS; Olsen PS; Rasmussen B; Vogelsang G
Ugeskr Laeger; 2000 Jun; 162(26):3717-22. PubMed ID: 10925631
[TBL] [Abstract][Full Text] [Related]
9. Axial flow blood pumps.
Song X; Throckmorton AL; Untaroiu A; Patel S; Allaire PE; Wood HG; Olsen DB
ASAIO J; 2003; 49(4):355-64. PubMed ID: 12918574
[TBL] [Abstract][Full Text] [Related]
10. Bridge to transplantation with the MicroMed DeBakey ventricular assist device axial pump: a single centre report.
Bruschi G; Ribera E; Lanfranconi M; Russo C; Colombo T; Garatti A; Oliva F; Milazzo F; Frigerio M; Vitali E
J Cardiovasc Med (Hagerstown); 2006 Feb; 7(2):114-8. PubMed ID: 16645370
[TBL] [Abstract][Full Text] [Related]
11. Current status of the gyro centrifugal blood pump--development of the permanently implantable centrifugal blood pump as a biventricular assist device (NEDO project).
Nosé Y; Furukawa K
Artif Organs; 2004 Oct; 28(10):953-8. PubMed ID: 15385004
[TBL] [Abstract][Full Text] [Related]
12. Development of mechanical circulatory support devices in China.
Wang W; Zhu DM; Ding WX
Artif Organs; 2009 Nov; 33(11):1009-14. PubMed ID: 20021474
[TBL] [Abstract][Full Text] [Related]
13. Current axial-flow devices--the HeartMate II and Jarvik 2000 left ventricular assist devices.
John R
Semin Thorac Cardiovasc Surg; 2008; 20(3):264-72. PubMed ID: 19038737
[TBL] [Abstract][Full Text] [Related]
14. Endocrine function is not impaired in patients with a continuous MicroMed-DeBakey axial flow pump.
Wieselthaler GM; Riedl M; Schima H; Wagner O; Waldhäusl W; Wolner E; Luger A; Clodi M
J Thorac Cardiovasc Surg; 2007 Jan; 133(1):2-6. PubMed ID: 17198773
[TBL] [Abstract][Full Text] [Related]
15. Pediatric circulatory support: current strategies and future directions. Biventricular and univentricular mechanical assistance.
Throckmorton AL; Chopski SG
ASAIO J; 2008; 54(5):491-7. PubMed ID: 18812740
[TBL] [Abstract][Full Text] [Related]
16. [Assisted circulation: an overview from a clinical perspective].
Spillner J; Kopp R; Finocchiaro T; Behbahani M; Rossaint R; Steinseifer U; Behr M; Autschbach R
Biomed Tech (Berl); 2009 Oct; 54(5):255-67. PubMed ID: 19807289
[TBL] [Abstract][Full Text] [Related]
17. Cardiac extracorporeal life support: state of the art in 2007.
Cooper DS; Jacobs JP; Moore L; Stock A; Gaynor JW; Chancy T; Parpard M; Griffin DA; Owens T; Checchia PA; Thiagarajan RR; Spray TL; Ravishankar C
Cardiol Young; 2007 Sep; 17 Suppl 2():104-15. PubMed ID: 18039404
[TBL] [Abstract][Full Text] [Related]
18. Destination therapy: time for real progress.
Westaby S
Nat Clin Pract Cardiovasc Med; 2008 Aug; 5(8):477-83. PubMed ID: 18560406
[TBL] [Abstract][Full Text] [Related]
19. [Assisted circulation. I. Systems with short-term mechanical circulatory support].
Nezić D; Perić M; Knezević A; Radomir B; Jović M; Kapelak B; Bojić M
Acta Chir Iugosl; 2001; 48(1):59-64. PubMed ID: 11432255
[TBL] [Abstract][Full Text] [Related]
20. Clinical spectrum of mechanical circulatory assistance.
Richenbacher WE; Pierce WS
J Heart Transplant; 1985; 4(5):481-8. PubMed ID: 3916523
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]