BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

188 related articles for article (PubMed ID: 16304473)

  • 1. Medicolegal aspects of an unusual uterine perforation with multiload-Cu 375R.
    Grimaldi L; De Giorgio F; Andreotta P; D'Alessio MC; Piscicelli C; Pascali VL
    Am J Forensic Med Pathol; 2005 Dec; 26(4):365-6. PubMed ID: 16304473
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Uterine perforation by GyneFix frameless IUD: two case reports.
    Gandhi JD; Whitmore J; Iskander MN
    J Fam Plann Reprod Health Care; 2001 Jul; 27(3):153-4. PubMed ID: 12457496
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Uterine perforation by copper intrauterine device.
    Heinonen PK; Merikari M; Paavonen J
    Eur J Obstet Gynecol Reprod Biol; 1984 Jun; 17(4):257-61. PubMed ID: 6378687
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Laparoscopic removal of translocated intrauterine contraceptives devices.
    McKenna PJ; Mylotte MJ
    Br J Obstet Gynaecol; 1982 Feb; 89(2):163-5. PubMed ID: 6461352
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Perforation of the uterus by the copper-t and copper-7 intrauterine contraceptive devices.
    Cederqvist LL; Lindhe BA; Fuchs F
    Acta Obstet Gynecol Scand; 1975; 54(2):183-9. PubMed ID: 1169868
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Levonorgestrel-Releasing Intrauterine Contraceptive Device in the Peritoneal Cavity: A Report of Two Cases.
    Starič KD; Taneska P; Zore A; Lukanović A; Kobal B; Cvjetićanin B; Jakopič K
    J Reprod Med; 2017; 62(3-4):215-17. PubMed ID: 30230800
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Complete and partial uterine perforation and embedding following insertion of intrauterine devices. II. Diagnostic methods, prevention, and management.
    Zakin D; Stern WZ; Rosenblatt R
    Obstet Gynecol Surv; 1981 Aug; 36(8):401-17. PubMed ID: 6455610
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A lost intrauterine device. Guess where we found it and how it happened?
    Mülayim B; Mülayim S; Celik NY
    Eur J Contracept Reprod Health Care; 2006 Mar; 11(1):47-9. PubMed ID: 16546816
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Ileal penetration by a Multiload-Cu 375 intrauterine contraceptive device. A case report with review of the literature.
    Chen CP; Hsu TC; Wang W
    Contraception; 1998 Nov; 58(5):295-304. PubMed ID: 9883385
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Intravesical migration of a GyneFix intrauterine device.
    Eskandar OS; Eckford SD
    J Fam Plann Reprod Health Care; 2003 Oct; 29(4):237-8. PubMed ID: 14662059
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Migration of intrauterine devices: radiologic findings and implications for patient care.
    Boortz HE; Margolis DJ; Ragavendra N; Patel MK; Kadell BM
    Radiographics; 2012; 32(2):335-52. PubMed ID: 22411936
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Complete and partial uterine perforation and embedding following insertion of intrauterine devices. I. Classification, complications, mechanism, incidence, and missing string.
    Zakin D; Stern WZ; Rosenblatt R
    Obstet Gynecol Surv; 1981 Jul; 36(7):335-53. PubMed ID: 7029368
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Intrauterine contraceptive device appendicitis: a case report.
    Chang HM; Chen TW; Hsieh CB; Chen CJ; Yu JC; Liu YC; Shen KL; Chan DC
    World J Gastroenterol; 2005 Sep; 11(34):5414-5. PubMed ID: 16149161
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Extrauterine mislocated IUD: is surgical removal mandatory?
    Markovitch O; Klein Z; Gidoni Y; Holzinger M; Beyth Y
    Contraception; 2002 Aug; 66(2):105-8. PubMed ID: 12204783
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Early sonographic diagnosis of intrauterine device migration to the adnexa.
    Deshmukh S; Ghanouni P; Jeffrey RB
    J Clin Ultrasound; 2009 Sep; 37(7):414-6. PubMed ID: 19484740
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Uterine perforation caused by intrauterine devices: clinical course and treatment.
    Kaislasuo J; Suhonen S; Gissler M; Lähteenmäki P; Heikinheimo O
    Hum Reprod; 2013 Jun; 28(6):1546-51. PubMed ID: 23526304
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Uterine perforation by the intra-uterine device.
    Raman S; Sivanesaratnam V; Sinnathuray TA
    Med J Malaysia; 1981 Sep; 36(3):151-4. PubMed ID: 7199110
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Ureteral displacement due to a migrated intrauterine contraceptive device.
    Sirikci A; Sarica K; Bayram M
    Urol Int; 2000; 65(3):179-80. PubMed ID: 11054041
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [The 'lost' intra-uterine contraceptive device (author's transl)].
    Tadjerouni A; Flici O; Wauters G; Hubinont PO
    J Gynecol Obstet Biol Reprod (Paris); 1981; 10(5):473-8. PubMed ID: 7033343
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Translocation of the Dalkon Shield into the broad ligament.
    Cederqvist LL; Sarry ZI; Zervoudakis IA
    Obstet Gynecol; 1975 Aug; 46(2):239-42. PubMed ID: 1171420
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.