BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

394 related articles for article (PubMed ID: 16305867)

  • 1. Stentless aortic valves are hemodynamically superior to stented valves during mid-term follow-up: a large retrospective study.
    Borger MA; Carson SM; Ivanov J; Rao V; Scully HE; Feindel CM; David TE
    Ann Thorac Surg; 2005 Dec; 80(6):2180-5. PubMed ID: 16305867
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Are stentless valves hemodynamically superior to stented valves? Long-term follow-up of a randomized trial comparing Carpentier-Edwards pericardial valve with the Toronto Stentless Porcine Valve.
    Cohen G; Zagorski B; Christakis GT; Joyner CD; Vincent J; Sever J; Harbi S; Feder-Elituv R; Moussa F; Goldman BS; Fremes SE
    J Thorac Cardiovasc Surg; 2010 Apr; 139(4):848-59. PubMed ID: 20080264
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The Toronto root stentless valve in the subcoronary position is hemodynamically superior to the mosaic stented completely supra-annular bioprosthesis.
    Bleiziffer S; Eichinger WB; Wagner I; Guenzinger R; Bauernschmitt R; Lange R
    J Heart Valve Dis; 2005 Nov; 14(6):814-21; discussion 821. PubMed ID: 16359064
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Meta-analysis of valve hemodynamics and left ventricular mass regression for stentless versus stented aortic valves.
    Kunadian B; Vijayalakshmi K; Thornley AR; de Belder MA; Hunter S; Kendall S; Graham R; Stewart M; Thambyrajah J; Dunning J
    Ann Thorac Surg; 2007 Jul; 84(1):73-8. PubMed ID: 17588387
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The subcoronary Toronto stentless versus supra-annular Perimount stented replacement aortic valve: early clinical and hemodynamic results of a randomized comparison in 160 patients.
    Chambers JB; Rimington HM; Hodson F; Rajani R; Blauth CI
    J Thorac Cardiovasc Surg; 2006 Apr; 131(4):878-2. PubMed ID: 16580447
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Stentless bioprostheses improve postoperative coronary flow more than stented prostheses after valve replacement for aortic stenosis.
    Bakhtiary F; Schiemann M; Dzemali O; Wittlinger T; Doss M; Ackermann H; Moritz A; Kleine P
    J Thorac Cardiovasc Surg; 2006 Apr; 131(4):883-8. PubMed ID: 16580448
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Influence of completely supra-annular placement of bioprostheses on exercise hemodynamics in patients with a small aortic annulus.
    Wagner IM; Eichinger WB; Bleiziffer S; Botzenhardt F; Gebauer I; Guenzinger R; Bauernschmitt R; Lange R
    J Thorac Cardiovasc Surg; 2007 May; 133(5):1234-41. PubMed ID: 17467435
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Impact of small valve size on hemodynamics and left ventricular mass regression with the Toronto SPV stentless aortic bioprosthesis.
    Bach DS; Goldman B; Verrier E; Petracek M; Wood J; Goldman S; David T;
    J Heart Valve Dis; 2002 Mar; 11(2):236-41. PubMed ID: 12000166
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Prosthesis-patient mismatch: hemodynamic comparison of stented and stentless aortic valves.
    Yun KL; Jamieson WR; Khonsari S; Burr LH; Munro AI; Sintek CF
    Semin Thorac Cardiovasc Surg; 1999 Oct; 11(4 Suppl 1):98-102. PubMed ID: 10660175
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Long-term results with the Biocor-SJM stentless porcine aortic bioprosthesis.
    Vrandecic M; Fantini FA; Filho BG; de O; da C; Vrandecic E
    J Heart Valve Dis; 2002 Jan; 11(1):47-53. PubMed ID: 11843505
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Midterm survival of stented versus stentless valves: does concomitant coronary artery bypass grafting impact survival?
    Del Rizzo DF; Freed D; Abdoh A; Doty D; Goldman BS; Jamieson WR; Westaby S
    Semin Thorac Cardiovasc Surg; 2001 Oct; 13(4 Suppl 1):148-55. PubMed ID: 11805964
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Aortic valve replacement with the Sorin Pericarbon Freedom stentless valve: five-year follow up.
    Nyawo B; Graham R; Hunter S
    J Heart Valve Dis; 2007 Jan; 16(1):42-8. PubMed ID: 17315382
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Stentless bioprostheses for the small aortic root.
    Walther T; Falk V; Diegeler A; Autschbach R; Gummert J; Baryalei M; Mohr FW
    J Heart Valve Dis; 1996 Nov; 5 Suppl 3():S302-7. PubMed ID: 8953458
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Stentless aortic valve reoperations: a surgical challenge.
    Borger MA; Prasongsukarn K; Armstrong S; Feindel CM; David TE
    Ann Thorac Surg; 2007 Sep; 84(3):737-43; discussion 743-4. PubMed ID: 17720369
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Stentless versus conventional xenograft aortic valve replacement: midterm results of a prospectively randomized trial.
    Lehmann S; Walther T; Kempfert J; Leontjev S; Rastan A; Falk V; Mohr FW
    Ann Thorac Surg; 2007 Aug; 84(2):467-72. PubMed ID: 17643617
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Aortic valve replacement with stentless porcine aortic valves: a ten-year experience.
    David TE; Feindel CM; Scully HE; Bos J; Rakowski H
    J Heart Valve Dis; 1998 May; 7(3):250-4. PubMed ID: 9651835
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Stentless valves versus stented bioprostheses at the aortic position: midterm results.
    Narang S; Satsangi DK; Banerjee A; Geelani MA
    J Thorac Cardiovasc Surg; 2008 Oct; 136(4):943-7. PubMed ID: 18954634
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Is routine use of stentless aortic prostheses justified in an elderly (aged > or =75 years) population?
    Ali A; Kumar P; Athanasiou T; Halstead J; Ashrafian H; Ali Z; Kumar S; Theodorou P; Pepper JR
    J Heart Valve Dis; 2005 Jan; 14(1):64-70; discussion 70-1. PubMed ID: 15700438
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Stentless and stented aortic valve replacement in elderly patients: Factors affecting midterm clinical and hemodynamical outcome.
    Bové T; Van Belleghem Y; François K; Caes F; Van Overbeke H; Van Nooten G
    Eur J Cardiothorac Surg; 2006 Nov; 30(5):706-13. PubMed ID: 16950630
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Influence of valve prosthesis type on the recovery of ventricular dysfunction and subendocardial ischaemia following valve replacement for aortic stenosis.
    Collinson J; Flather M; Coats AJ; Pepper JR; Henein M
    Int J Cardiol; 2004 Dec; 97(3):535-41. PubMed ID: 15561345
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 20.