BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

161 related articles for article (PubMed ID: 16306841)

  • 1. A prospective analysis of intraoperative electromyographic monitoring of posterior cervical screw fixation.
    Djurasovic M; Dimar JR; Glassman SD; Edmonds HL; Carreon LY
    J Spinal Disord Tech; 2005 Dec; 18(6):515-8. PubMed ID: 16306841
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Ability of electromyographic monitoring to determine the presence of malpositioned pedicle screws in the lumbosacral spine: analysis of 2450 consecutively placed screws.
    Parker SL; Amin AG; Farber SH; McGirt MJ; Sciubba DM; Wolinsky JP; Bydon A; Gokaslan ZL; Witham TF
    J Neurosurg Spine; 2011 Aug; 15(2):130-5. PubMed ID: 21529126
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Lateral mass screw stimulation thresholds in posterior cervical instrumentation surgery: a predictor of medial deviation.
    Wilson B; Curtis E; Hirshman B; Oygar A; Chen K; Gabel BC; Vaida F; Allison DW; Ciacci JD
    J Neurosurg Spine; 2017 Mar; 26(3):346-352. PubMed ID: 27935447
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Intraoperative electromyography for pedicle screws: technique is the key!
    Dickerman RD; Guyer R
    J Spinal Disord Tech; 2006 Aug; 19(6):463. PubMed ID: 16891985
    [No Abstract]   [Full Text] [Related]  

  • 5. Electrical stimulation for intraoperative evaluation of thoracic pedicle screw placement.
    Shi YB; Binette M; Martin WH; Pearson JM; Hart RA
    Spine (Phila Pa 1976); 2003 Mar; 28(6):595-601. PubMed ID: 12642768
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A prospective analysis of intraoperative electromyographic monitoring of pedicle screw placement with computed tomographic scan confirmation.
    Glassman SD; Dimar JR; Puno RM; Johnson JR; Shields CB; Linden RD
    Spine (Phila Pa 1976); 1995 Jun; 20(12):1375-9. PubMed ID: 7676335
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Using triggered electromyographic threshold in the intercostal muscles to evaluate the accuracy of upper thoracic pedicle screw placement (T3-T6).
    Rodriguez-Olaverri JC; Zimick NC; Merola A; De Blas G; Burgos J; Piza-Vallespir G; Hevia E; Vicente J; Sanper I; Domenech P; Regidor I
    Spine (Phila Pa 1976); 2008 Apr; 33(7):E194-7. PubMed ID: 18379388
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Electromyography stimulation compared with intraoperative O-arm imaging for evaluating pedicle screw breaches in lumbar spine surgery: a prospective analysis of 1006 screws in 164 patients.
    Ravindra VM; Kalra RR; Dailey AT
    Spine J; 2019 Feb; 19(2):206-211. PubMed ID: 29960110
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Safe pedicle screw placement in thoracic scoliotic curves using t-EMG: stimulation threshold variability at concavity and convexity in apex segments.
    de Blas G; Barrios C; Regidor I; Montes E; Burgos J; Pizá-Vallespir G; Hevia E
    Spine (Phila Pa 1976); 2012 Mar; 37(6):E387-95. PubMed ID: 22024903
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Utility of intraoperative electromyography in placing C7 pedicle screws.
    Rasouli JJ; Kennamer BT; Moore FM; Steinberger A; Yao KC; Syed ON; Arginteanu MS; Gologorsky Y
    J Neurosurg Spine; 2020 Jan; 32(6):891-899. PubMed ID: 32005025
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Correlation between low triggered electromyographic thresholds and lumbar pedicle screw malposition: analysis of 4857 screws.
    Raynor BL; Lenke LG; Bridwell KH; Taylor BA; Padberg AM
    Spine (Phila Pa 1976); 2007 Nov; 32(24):2673-8. PubMed ID: 18007243
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Stimulus-evoked electromyography testing of percutaneous pedicle screws for the detection of pedicle breaches: a clinical study of 409 screws in 93 patients.
    Wang MY; Pineiro G; Mummaneni PV
    J Neurosurg Spine; 2010 Nov; 13(5):600-5. PubMed ID: 21039151
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Pulse-train stimulation for detecting medial malpositioning of thoracic pedicle screws.
    Donohue ML; Murtagh-Schaffer C; Basta J; Moquin RR; Bashir A; Calancie B
    Spine (Phila Pa 1976); 2008 May; 33(12):E378-85. PubMed ID: 18496333
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Recording diffusion responses from contralateral intercostal muscles after stimulus-triggered electromyography: refining a tool for the assessment of thoracic pedicle screw placement in an experimental porcine model.
    de Blas G; Burgos J; Regidor I; Barrios C; Solá R; García-Urquiza S; Hevia E
    Spine (Phila Pa 1976); 2009 May; 34(11):E391-6. PubMed ID: 19444052
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Assessment of pedicle perforation by the cervical pedicle screw placement using plain radiographs: a comparison with computed tomography.
    Lee SH; Kim KT; Suk KS; Lee JH; Son ES; Kwack YH; Oh HS
    Spine (Phila Pa 1976); 2012 Feb; 37(4):280-5. PubMed ID: 21629168
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [The Effect of Intraoperative Screw Monitoring (Root Monitoring) with the INS-1 System (NUVASIVE) on the Radiological Outcome of Dorsal Instrumentation of the Lumbar Spine].
    Bernhardt G; Awiszus F; Meister U; Heyde CE; Böhm H
    Z Orthop Unfall; 2016 Jun; 154(3):269-74. PubMed ID: 27351159
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Utility of evoked EMG monitoring to improve bone screw placements in the cervical spine.
    Holdefer RN; Heffez DS; Cohen BA
    J Spinal Disord Tech; 2013 Jul; 26(5):E163-9. PubMed ID: 23429315
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Neuromonitoring with pulse-train stimulation for implantation of thoracic pedicle screws: a blinded and randomized clinical study. Part 1. Methods and alarm criteria.
    Calancie B; Donohue ML; Harris CB; Canute GW; Singla A; Wilcoxen KG; Moquin RR
    J Neurosurg Spine; 2014 Jun; 20(6):675-91. PubMed ID: 24684171
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Can triggered electromyograph thresholds predict safe thoracic pedicle screw placement?
    Raynor BL; Lenke LG; Kim Y; Hanson DS; Wilson-Holden TJ; Bridwell KH; Padberg AM
    Spine (Phila Pa 1976); 2002 Sep; 27(18):2030-5. PubMed ID: 12634564
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Paravertebral foramen screw fixation for posterior cervical spine fusion: biomechanical study and description of a novel technique.
    Maki S; Aramomi M; Matsuura Y; Furuya T; Ota M; Iijima Y; Saito J; Suzuki T; Mannoji C; Takahashi K; Yamazaki M; Koda M
    J Neurosurg Spine; 2017 Oct; 27(4):415-420. PubMed ID: 28498072
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.