254 related articles for article (PubMed ID: 16311453)
1. Artifact reduction in magnetogastrography using fast independent component analysis.
Irimia A; Bradshaw LA
Physiol Meas; 2005 Dec; 26(6):1059-73. PubMed ID: 16311453
[TBL] [Abstract][Full Text] [Related]
2. Dependent component analysis for the magnetogastrographic detection of human electrical response activity.
Estombelo-Montesco CA; de Araujo DB; Silva Filho AC; Moraes ER; Barros AK; Wakai RT; Baffa O
Physiol Meas; 2007 Sep; 28(9):1029-44. PubMed ID: 17827651
[TBL] [Abstract][Full Text] [Related]
3. Real time ECG artifact removal for myoelectric prosthesis control.
Zhou P; Lock B; Kuiken TA
Physiol Meas; 2007 Apr; 28(4):397-413. PubMed ID: 17395995
[TBL] [Abstract][Full Text] [Related]
4. Adaptive filtering of ECG interference on surface EEnGs based on signal averaging.
Garcia-Casado J; Martinez-de-Juan JL; Ponce JL
Physiol Meas; 2006 Jun; 27(6):509-27. PubMed ID: 16603800
[TBL] [Abstract][Full Text] [Related]
5. Magnetogastrographic detection of gastric electrical response activity in humans.
Irimia A; Richards WO; Bradshaw LA
Phys Med Biol; 2006 Mar; 51(5):1347-60. PubMed ID: 16481699
[TBL] [Abstract][Full Text] [Related]
6. Identification of the slow wave component of the electroenterogram from Laplacian abdominal surface recordings in humans.
Prats-Boluda G; Garcia-Casado J; Martinez-de-Juan JL; Ponce JL
Physiol Meas; 2007 Sep; 28(9):1115-33. PubMed ID: 17827658
[TBL] [Abstract][Full Text] [Related]
7. Artifact removal in magnetoencephalogram background activity with independent component analysis.
Escudero J; Hornero R; Abásolo D; Fernández A; López-Coronado M
IEEE Trans Biomed Eng; 2007 Nov; 54(11):1965-73. PubMed ID: 18018691
[TBL] [Abstract][Full Text] [Related]
8. Adaptive and wavelet filtering methods for improving accuracy of respiratory measurement.
Keenan DB; Wilhelm FH
Biomed Sci Instrum; 2005; 41():37-42. PubMed ID: 15850079
[TBL] [Abstract][Full Text] [Related]
9. A simple method to remove ECG artifacts from trunk muscle EMG signals.
Hof AL
J Electromyogr Kinesiol; 2009 Dec; 19(6):e554-5. PubMed ID: 19121951
[No Abstract] [Full Text] [Related]
10. [Application of independent component analysis to ECG cancellation in surface electromyography measurement].
Cao Y; Chen C; Hu Y
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2005 Aug; 22(4):686-9. PubMed ID: 16156250
[TBL] [Abstract][Full Text] [Related]
11. Noninvasive measurement and analysis of intestinal myoelectrical activity using surface electrodes.
Garcia-Casado J; Martinez-de-Juan JL; Ponce JL
IEEE Trans Biomed Eng; 2005 Jun; 52(6):983-91. PubMed ID: 15977728
[TBL] [Abstract][Full Text] [Related]
12. Motion artifact reduction in photoplethysmography using independent component analysis.
Kim BS; Yoo SK
IEEE Trans Biomed Eng; 2006 Mar; 53(3):566-8. PubMed ID: 16532785
[TBL] [Abstract][Full Text] [Related]
13. Canonical correlation analysis applied to remove muscle artifacts from the electroencephalogram.
De Clercq W; Vergult A; Vanrumste B; Van Paesschen W; Van Huffel S
IEEE Trans Biomed Eng; 2006 Dec; 53(12 Pt 1):2583-7. PubMed ID: 17153216
[TBL] [Abstract][Full Text] [Related]
14. Comparison of conventional filtering and independent component analysis for artifact reduction in simultaneous gastric EMG and magnetogastrography from porcines.
Irimia A; Richards WO; Bradshaw LA
IEEE Trans Biomed Eng; 2009 Nov; 56(11):2611-8. PubMed ID: 19398400
[TBL] [Abstract][Full Text] [Related]
15. Filtering noise for synchronised activity in multi-trial electrophysiology data using Wiener and Kalman filters.
Zhan Y; Guo S; Kendrick KM; Feng J
Biosystems; 2009 Apr; 96(1):1-13. PubMed ID: 19084574
[TBL] [Abstract][Full Text] [Related]
16. Application of decorrelation-independent component analysis to biomagnetic multi-channel measurements.
Sander TH; Burghoff M; Van Leeuwen P; Trahms L
Biomed Tech (Berl); 2007 Feb; 52(1):130-6. PubMed ID: 17313349
[TBL] [Abstract][Full Text] [Related]
17. A wavelet-based adaptive filter for removing ECG interference in EMGdi signals.
Zhan C; Yeung LF; Yang Z
J Electromyogr Kinesiol; 2010 Jun; 20(3):542-9. PubMed ID: 19692270
[TBL] [Abstract][Full Text] [Related]
18. [Removal of artifacts from EEG signal].
Du X; Li Y; Zhu Y; Ren Q; Zhao L
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2008 Apr; 25(2):464-7, 471. PubMed ID: 18610643
[TBL] [Abstract][Full Text] [Related]
19. Improving MEG source localizations: an automated method for complete artifact removal based on independent component analysis.
Mantini D; Franciotti R; Romani GL; Pizzella V
Neuroimage; 2008 Mar; 40(1):160-73. PubMed ID: 18155928
[TBL] [Abstract][Full Text] [Related]
20. Limitations and applications of ICA for surface electromyogram.
Djuwari D; Kumar DK; Naik GR; Arjunan SP; Palaniswami M
Electromyogr Clin Neurophysiol; 2006 Sep; 46(5):295-309. PubMed ID: 17059103
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]