These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

82 related articles for article (PubMed ID: 16311939)

  • 1. Echocardiography induced tachycardia in a patient with a minute ventilation rate responsive pacemaker.
    Khunnawat C; Mukerji S; Sankaran S; Thakur RK
    J Interv Card Electrophysiol; 2005 Oct; 14(1):51-3. PubMed ID: 16311939
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Wide QRS complex tachycardia in a patient with a minute ventilation rate-responsive pacemaker.
    Mukerji S; Khunnawat C; Sankaran S; Thakur RK
    Pacing Clin Electrophysiol; 2006 Mar; 29(3):296-7. PubMed ID: 16606398
    [No Abstract]   [Full Text] [Related]  

  • 3. Monitoring equipment induced tachycardia in patients with minute ventilation rate-responsive pacemakers.
    Southorn PA; Kamath GS; Vasdev GM; Hayes DL
    Br J Anaesth; 2000 Apr; 84(4):508-9. PubMed ID: 10823106
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Pacemaker-driven tachycardia induced by electrocardiograph monitoring in the recovery room.
    Hu R; Cowie DA
    Anaesth Intensive Care; 2006 Apr; 34(2):266-8. PubMed ID: 16617652
    [TBL] [Abstract][Full Text] [Related]  

  • 5. "Wide QRS complex tachycardia in a patient with a minute ventilation (MV) rate-responsive pacemaker".
    Balt JC; Dekker P; de Voogt WG
    Pacing Clin Electrophysiol; 2006 Oct; 29(10):1185; author reply 1185-6. PubMed ID: 17038155
    [No Abstract]   [Full Text] [Related]  

  • 6. Pacemaker-mediated tachycardia in the absence of retrograde ventriculoatrial conduction: What is the mechanism?
    Méndez-Zurita F; Rodríguez-Font E; Alonso-Martín C; Guerra-Ramos JM; Viñolas X
    J Cardiovasc Electrophysiol; 2018 Dec; 29(12):1721-1723. PubMed ID: 30155935
    [No Abstract]   [Full Text] [Related]  

  • 7. Upper limit ventricular stimulation in respiratory rate responsive pacing due to electrocautery.
    Van Hemel NM; Hamerlijnck RP; Pronk KJ; Van der Veen EP
    Pacing Clin Electrophysiol; 1989 Nov; 12(11):1720-3. PubMed ID: 2478969
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Inappropriate rate response in a VVI-R pacemaker.
    Vanderheyden M; Timmermans W; Goethals M
    Acta Cardiol; 1996; 51(6):545-50. PubMed ID: 9124025
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Interaction of frequency-adaptive pacemakers and anesthetic management. Discussion of current literature and two case reports].
    von Knobelsdorff G; Goerig M; Nägele H; Scholz J
    Anaesthesist; 1996 Sep; 45(9):856-60. PubMed ID: 8967604
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Pacemaker-induced tachycardia during general anaesthesia: a case report.
    Madsen GM; Andersen C
    Br J Anaesth; 1989 Sep; 63(3):360-1. PubMed ID: 2803896
    [TBL] [Abstract][Full Text] [Related]  

  • 11. External monitoring-induced pacemaker-driven tachycardia: a case report.
    Trocinski DR; Pickens AT
    J Emerg Med; 2011 Feb; 40(2):e31-3. PubMed ID: 19111428
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Orthodromic pacemaker-mediated tachycardia in a biventricular system without an atrial electrode.
    Berruezo A; Mont L; Scalise A; Brugada J
    J Cardiovasc Electrophysiol; 2004 Sep; 15(9):1100-2. PubMed ID: 15363087
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A patient with dizziness, tachycardia and a DDDR pacemaker.
    Balt JC; Dekker P; de Voogt WG
    Neth Heart J; 2006 Jan; 14(1):28-30. PubMed ID: 25696553
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Runaway pacemaker--an unusual presentation--a case report.
    Kaul UA; Chutani SK; Tyagi S; Khalilullah M
    Indian Heart J; 1987; 39(1):76-8. PubMed ID: 3450573
    [No Abstract]   [Full Text] [Related]  

  • 15. Repetitive ventricular tachyarrhythmia: result of pacemaker failure.
    Devorss J; Winters WG
    JAMA; 1972 Jun; 220(11):1494. PubMed ID: 5067587
    [No Abstract]   [Full Text] [Related]  

  • 16. Pacemaker tachycardia in a minute ventilation rate-adaptive pacemaker induced by electrocardiographic monitoring.
    Lau W; Corcoran SJ; Mond HG
    Pacing Clin Electrophysiol; 2006 Apr; 29(4):438-40. PubMed ID: 16650278
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [A case of pacemaker-induced tachycardia].
    Krauss H
    Med Klin; 1980 May; 75(10):367-9. PubMed ID: 7393103
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Circadian variations in minute ventilation can be reproduced by a pacemaker sensor.
    Bonnet JL; Vai F; Pioger G; Garrigue S; Clémenty J; Cazeau S
    Pacing Clin Electrophysiol; 1998 Apr; 21(4 Pt 1):701-5. PubMed ID: 9584300
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Myopotential interference with a unipolar VDD pacemaker presenting with tachycardia and transient ventricular asystole.
    Liang HY; Lee CS; Lin CC; Chen YF
    Kaohsiung J Med Sci; 2002 Dec; 18(12):632-5. PubMed ID: 12670040
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Pacemaker induced ventricular tachycardia. Report of a case with the "runaway pacemaker".
    Garcia R; Arciniegas E
    Henry Ford Hosp Med J; 1969; 17(1):15-8. PubMed ID: 5802145
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 5.