These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

182 related articles for article (PubMed ID: 16314716)

  • 21. Distal femoral fractures in the elderly: biomechanical analysis of a polyaxial angle-stable locking plate versus a retrograde intramedullary nail in a human cadaveric bone model.
    Bliemel C; Buecking B; Mueller T; Wack C; Koutras C; Beck T; Ruchholtz S; Zettl R
    Arch Orthop Trauma Surg; 2015 Jan; 135(1):49-58. PubMed ID: 25388863
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Rotationally Stable Screw-Anchor With Locked Trochanteric Stabilizing Plate Versus Proximal Femoral Nail Antirotation in the Treatment of AO/OTA 31A2.2 Fracture: A Biomechanical Evaluation.
    Knobe M; Nagel P; Maier KJ; Gradl G; Buecking B; Sönmez TT; Modabber A; Prescher A; Pape HC
    J Orthop Trauma; 2016 Jan; 30(1):e12-8. PubMed ID: 26849388
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Angular stability potentially permits fewer locking screws compared with conventional locking in intramedullary nailed distal tibia fractures: a biomechanical study.
    Gueorguiev B; Ockert B; Schwieger K; Wähnert D; Lawson-Smith M; Windolf M; Stoffel K
    J Orthop Trauma; 2011 Jun; 25(6):340-6. PubMed ID: 21577069
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Stress analysis of the distal locking screws for femoral interlocking nailing.
    Lin J; Lin SJ; Chen PQ; Yang SH
    J Orthop Res; 2001 Jan; 19(1):57-63. PubMed ID: 11332621
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Influence of gap size, screw configuration, and nail materials in the stability of anterograde reamed intramedullary nail in femoral transverse fractures.
    Gabarre S; Albareda J; Gracia L; Puértolas S; Ibarz E; Herrera A
    Injury; 2017 Nov; 48 Suppl 6():S40-S46. PubMed ID: 29162240
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Antegrade nailing of femoral shaft fractures combined with neck or distal femur fractures. A retrospective review of 25 cases, with a follow-up of 36-150 months.
    Okcu G; Aktuglu K
    Arch Orthop Trauma Surg; 2003 Dec; 123(10):544-50. PubMed ID: 13680274
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Internal fixation of type-C distal femoral fractures in osteoporotic bone: surgical technique.
    Mückley T; Wähnert D; Hoffmeier KL; von Oldenburg G; Fröber R; Hofmann GO
    J Bone Joint Surg Am; 2011 Mar; 93 Suppl 1():40-53. PubMed ID: 21411685
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Fracture strain and stability with additional locking screws in intramedullary nailing: a biomechanical study.
    Sayana MK; Davis BJ; Kapoor B; Rahmatalla A; Maffulli N
    J Trauma; 2006 May; 60(5):1053-7. PubMed ID: 16688070
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Optimal location of a single distal interlocking screw in intramedullary nailing of distal third femoral shaft fractures.
    George CJ; Lindsey RW; Noble PC; Alexander JW; Kamaric E
    J Orthop Trauma; 1998 May; 12(4):267-72. PubMed ID: 9619462
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Femoral nail osteosynthesis. Mechanical factors influencing the femoral antetorsion].
    Citak M; Kendoff D; Citak M; Gardner MJ; Oszwald M; Krettek C; Hüfner T
    Unfallchirurg; 2008 Apr; 111(4):240-6. PubMed ID: 18369578
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Comparison of 3 Methods for Maintaining Inter-Fragmentary Compression After Fracture Reduction and Fixation.
    Au B; Groundland J; Stoops TK; Santoni BG; Sagi HC
    J Orthop Trauma; 2017 Apr; 31(4):210-213. PubMed ID: 27984452
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Are locking screws advantageous with plate fixation of humeral shaft fractures? A biomechanical analysis of synthetic and cadaveric bone.
    O'Toole RV; Andersen RC; Vesnovsky O; Alexander M; Topoleski LD; Nascone JW; Sciadini MF; Turen C; Eglseder WA
    J Orthop Trauma; 2008; 22(10):709-15. PubMed ID: 18978547
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Biomechanical comparison of proximal locking plates and blade plates for the treatment of comminuted subtrochanteric femoral fractures.
    Floyd JC; O'Toole RV; Stall A; Forward DP; Nabili M; Shillingburg D; Hsieh A; Nascone JW
    J Orthop Trauma; 2009 Oct; 23(9):628-33. PubMed ID: 19897983
    [TBL] [Abstract][Full Text] [Related]  

  • 34. A critical analysis of the eccentric starting point for trochanteric intramedullary femoral nailing.
    Ostrum RF; Marcantonio A; Marburger R
    J Orthop Trauma; 2005; 19(10):681-6. PubMed ID: 16314714
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Factors influencing interlocking screw failure in unreamed small diameter nails--a biomechanical study using a distal tibia fracture model.
    Weninger P; Schueller M; Jamek M; Stanzl-Tschegg S; Redl H; Tschegg EK
    Clin Biomech (Bristol, Avon); 2009 May; 24(4):379-84. PubMed ID: 19231049
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Comparative endurance testing of the Biomet Matthews Nail and the dynamic compression screw, in simulated condylar and supracondylar femoral fractures.
    O'Connor-Read LM; Davidson JA; Davies BM; Matthews MG; Smirthwaite P
    Biomed Eng Online; 2008 Jan; 7():3. PubMed ID: 18208608
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Volar fixed-angle plating of distal radius fractures: screws versus pegs--a biomechanical study in a cadaveric model.
    Mehling I; Klitscher D; Mehling AP; Nowak TE; Sternstein W; Rommens PM; Müller LP
    J Orthop Trauma; 2012 Jul; 26(7):395-401. PubMed ID: 22011636
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Combination of anatomical locking plate and retrograde intramedullary nail in distal femoral fractures: comparison of mechanical stability.
    Başcı O; Karakaşlı A; Kumtepe E; Güran O; Havıtçıoğlu H
    Eklem Hastalik Cerrahisi; 2015; 26(1):21-6. PubMed ID: 25741916
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Periprosthetic femoral fracture fixation: a biomechanical comparison between proximal locking screws and cables.
    Graham SM; Mak JH; Moazen M; Leonidou A; Jones AC; Wilcox RK; Tsiridis E
    J Orthop Sci; 2015 Sep; 20(5):875-80. PubMed ID: 25968896
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Early Mechanical Failures of the Synthes Variable Angle Locking Distal Femur Plate.
    Tank JC; Schneider PS; Davis E; Galpin M; Prasarn ML; Choo AM; Munz JW; Achor TS; Kellam JF; Gary JL
    J Orthop Trauma; 2016 Jan; 30(1):e7-e11. PubMed ID: 26849390
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.