175 related articles for article (PubMed ID: 16322716)
1. Effect of the diastolic and systolic duration on valve cavitation in a pediatric pulsatile ventricular assist device.
Lukic B; Zapanta CM; Griffith KA; Weiss WJ
ASAIO J; 2005; 51(5):546-50. PubMed ID: 16322716
[TBL] [Abstract][Full Text] [Related]
2. Effect of systolic duration on mechanical heart valve cavitation in a pneumatic ventricular assist device: using a monoleaflet valve.
Lee H; Tatsumi E; Taenaka Y
ASAIO J; 2008; 54(1):25-30. PubMed ID: 18204312
[TBL] [Abstract][Full Text] [Related]
3. Effects of the driving condition of a pneumatic ventricular assist device on the cavitation intensity of the inlet and outlet mechanical heart valves.
Lee H; Tatsumi E; Taenaka Y
ASAIO J; 2009; 55(4):328-34. PubMed ID: 19506466
[TBL] [Abstract][Full Text] [Related]
4. Flow behavior within the 12-cc Penn State pulsatile pediatric ventricular assist device: an experimental study of the initial design.
Manning KB; Wivholm BD; Yang N; Fontaine AA; Deutsch S
Artif Organs; 2008 Jun; 32(6):442-52. PubMed ID: 18422800
[TBL] [Abstract][Full Text] [Related]
5. Mechanical heart valve performance in a pulsatile pediatric ventricular assist device.
Zapanta CM; Dourte LM; Doxtater BJ; Lukic B; Weiss WJ
ASAIO J; 2007; 53(1):87-96. PubMed ID: 17237654
[TBL] [Abstract][Full Text] [Related]
6. An in-vitro investigation of prosthetic heart valve cavitation in blood.
Garrison LA; Lamson TC; Deutsch S; Geselowitz DB; Gaumond RP; Tarbell JM
J Heart Valve Dis; 1994 Apr; 3 Suppl 1():S8-22; discussion S22-4. PubMed ID: 8061873
[TBL] [Abstract][Full Text] [Related]
7. Estimation of mechanical heart valve cavitation in a pneumatic ventricular assist device.
Lee H; Akagawa E; Homma A; Tsukiya T; Tatsumi E; Taenaka Y
J Artif Organs; 2007; 10(3):181-5. PubMed ID: 17846718
[TBL] [Abstract][Full Text] [Related]
8. Real-time in vitro observation of cavitation in a prosthetic heart valve.
Lamson TC; Stinebring DR; Deutsch S; Rosenberg G; Tarbell JM
ASAIO Trans; 1991; 37(3):M351-3. PubMed ID: 1751182
[TBL] [Abstract][Full Text] [Related]
9. Observation of cavitation pits on mechanical heart valve surfaces in an artificial heart used in in vitro testing.
Lee H; Homma A; Tatsumi E; Taenaka Y
J Artif Organs; 2010 Apr; 13(1):17-23. PubMed ID: 20155293
[TBL] [Abstract][Full Text] [Related]
10. Characteristics of cavitation intensity in a mechanical heart valve using a pulsatile device: synchronized analysis between visual images and pressure signals.
Lee H; Akagawa E; Tatsumi E; Taenaka Y
J Artif Organs; 2008; 11(2):60-6. PubMed ID: 18604610
[TBL] [Abstract][Full Text] [Related]
11. Energy equivalent pressure and total hemodynamic energy associated with the pressure-flow waveforms of a pediatric pulsatile ventricular assist device.
Weiss WJ; Lukic B; Undar A
ASAIO J; 2005; 51(5):614-7. PubMed ID: 16322727
[TBL] [Abstract][Full Text] [Related]
12. A parametric study of valve orientation on the flow patterns of the Penn State pulsatile pediatric ventricular assist device.
Roszelle BN; Deutsch S; Manning KB
ASAIO J; 2010; 56(4):356-63. PubMed ID: 20559131
[TBL] [Abstract][Full Text] [Related]
13. Characteristics of mechanical heart valve cavitation in a pneumatic ventricular assist device.
Lee H; Taenaka Y
Artif Organs; 2008 Jun; 32(6):453-60. PubMed ID: 18422801
[TBL] [Abstract][Full Text] [Related]
14. Effect of the bileaflet inlet valve angle on the flow of a pediatric ventricular assist device: Experimental analysis.
Lemos BLHD; Bortolin VAA; Amaral RL; Mazzetto M; Cestari IA; Meneghini JR
Artif Organs; 2022 Sep; 46(9):1833-1846. PubMed ID: 35524699
[TBL] [Abstract][Full Text] [Related]
15. Effect of structural compliance on cavitation threshold measurement of mechanical heart valves.
Guo GX; Adlparvar P; Howanec M; Roy J; Kafesjian R; Kingsbury C
J Heart Valve Dis; 1994 Apr; 3 Suppl 1():S77-83; discussion S83-4. PubMed ID: 8061872
[TBL] [Abstract][Full Text] [Related]
16. In vivo observation of cavitation on prosthetic heart valves.
Zapanta CM; Stinebring DR; Sneckenberger DS; Deutsch S; Geselowitz DB; Tarbell JM; Synder AJ; Rosenberg G; Weiss WJ; Pae WE; Pierce WS
ASAIO J; 1996; 42(5):M550-5. PubMed ID: 8944940
[TBL] [Abstract][Full Text] [Related]
17. Hydrodynamic characteristics of the Edwards MIRA bileaflet valve in a pneumatic ventricular assist device.
Lee H; Taenaka Y
ASAIO J; 2007; 53(4):397-402. PubMed ID: 17667221
[TBL] [Abstract][Full Text] [Related]
18. In vitro evaluation of right ventricular outflow tract reconstruction with bicuspid valved polytetrafluoroethylene conduit.
Dur O; Yoshida M; Manor P; Mayfield A; Wearden PD; Morell VO; Pekkan K
Artif Organs; 2010 Nov; 34(11):1010-6. PubMed ID: 21092044
[TBL] [Abstract][Full Text] [Related]
19. A method for real-time in vitro observation of cavitation on prosthetic heart valves.
Zapanta CM; Liszka EG; Lamson TC; Stinebring DR; Deutsch S; Geselowitz DB; Tarbell JM
J Biomech Eng; 1994 Nov; 116(4):460-8. PubMed ID: 7869722
[TBL] [Abstract][Full Text] [Related]
20. Mechanical heart valve cavitation: valve specific parameters.
Eichler MJ; Reul HM
Int J Artif Organs; 2004 Oct; 27(10):855-67. PubMed ID: 15560680
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]