105 related articles for article (PubMed ID: 16323155)
1. A simple geometrical description of the TrueFISP ideal transient and steady-state signal.
Schmitt P; Griswold MA; Gulani V; Haase A; Flentje M; Jakob PM
Magn Reson Med; 2006 Jan; 55(1):177-86. PubMed ID: 16323155
[TBL] [Abstract][Full Text] [Related]
2. On the use of steady-state signal equations for 2D TrueFISP imaging.
Coolen BF; Heijman E; Nicolay K; Strijkers GJ
Magn Reson Imaging; 2009 Jul; 27(6):815-22. PubMed ID: 19249169
[TBL] [Abstract][Full Text] [Related]
3. Inversion recovery TrueFISP: quantification of T(1), T(2), and spin density.
Schmitt P; Griswold MA; Jakob PM; Kotas M; Gulani V; Flentje M; Haase A
Magn Reson Med; 2004 Apr; 51(4):661-7. PubMed ID: 15065237
[TBL] [Abstract][Full Text] [Related]
4. T-one insensitive steady state imaging: a framework for purely T2-weighted TrueFISP.
Schmitt P; Jakob PM; Kotas M; Flentje M; Haase A; Griswold MA
Magn Reson Med; 2012 Aug; 68(2):409-20. PubMed ID: 22131223
[TBL] [Abstract][Full Text] [Related]
5. An analytical description of balanced steady-state free precession with finite radio-frequency excitation.
Bieri O
Magn Reson Med; 2011 Feb; 65(2):422-31. PubMed ID: 20859995
[TBL] [Abstract][Full Text] [Related]
6. New insights into the mechanisms of signal formation in RF-spoiled gradient echo sequences.
Denolin V; Azizieh C; Metens T
Magn Reson Med; 2005 Oct; 54(4):937-54. PubMed ID: 16155898
[TBL] [Abstract][Full Text] [Related]
7. On the transient phase of balanced SSFP sequences.
Scheffler K
Magn Reson Med; 2003 Apr; 49(4):781-3. PubMed ID: 12652552
[TBL] [Abstract][Full Text] [Related]
8. Fat attenuation using a dual steady-state balanced-SSFP sequence with periodically variable flip angles.
Absil J; Denolin V; Metens T
Magn Reson Med; 2006 Feb; 55(2):343-51. PubMed ID: 16402382
[TBL] [Abstract][Full Text] [Related]
9. On flow effects in balanced steady-state free precession imaging: pictorial description, parameter dependence, and clinical implications.
Markl M; Pelc NJ
J Magn Reson Imaging; 2004 Oct; 20(4):697-705. PubMed ID: 15390233
[TBL] [Abstract][Full Text] [Related]
10. Optimization of RF excitation to maximize signal and T2 contrast of tissues with rapid transverse relaxation.
Carl M; Bydder M; Du J; Takahashi A; Han E
Magn Reson Med; 2010 Aug; 64(2):481-90. PubMed ID: 20665792
[TBL] [Abstract][Full Text] [Related]
11. Flow effects in balanced steady state free precession imaging.
Markl M; Alley MT; Elkins CJ; Pelc NJ
Magn Reson Med; 2003 Nov; 50(5):892-903. PubMed ID: 14586999
[TBL] [Abstract][Full Text] [Related]
12. T2 measurement of the human myocardium using a T2-prepared transient-state TrueFISP sequence.
Huang TY; Liu YJ; Stemmer A; Poncelet BP
Magn Reson Med; 2007 May; 57(5):960-6. PubMed ID: 17457877
[TBL] [Abstract][Full Text] [Related]
13. Effects of in-pulse transverse relaxation in 3D ultrashort echo time sequences: analytical derivation, comparison to numerical simulation and experimental application at 3T.
Springer F; Steidle G; Martirosian P; Claussen CD; Schick F
J Magn Reson; 2010 Sep; 206(1):88-96. PubMed ID: 20637661
[TBL] [Abstract][Full Text] [Related]
14. Reduction of transient signal oscillations in true-FISP using a linear flip angle series magnetization preparation.
Deshpande VS; Chung YC; Zhang Q; Shea SM; Li D
Magn Reson Med; 2003 Jan; 49(1):151-7. PubMed ID: 12509831
[TBL] [Abstract][Full Text] [Related]
15. Are TrueFISP images T2/T1-weighted?
Huang TY; Huang IJ; Chen CY; Scheffler K; Chung HW; Cheng HC
Magn Reson Med; 2002 Oct; 48(4):684-8. PubMed ID: 12353286
[TBL] [Abstract][Full Text] [Related]
16. Magnetization preparation during the steady state: fat-saturated 3D TrueFISP.
Scheffler K; Heid O; Hennig J
Magn Reson Med; 2001 Jun; 45(6):1075-80. PubMed ID: 11378886
[TBL] [Abstract][Full Text] [Related]
17. B1+-mapping with the transient phase of unbalanced steady-state free precession.
Ganter C; Settles M; Dregely I; Santini F; Scheffler K; Bieri O
Magn Reson Med; 2013 Dec; 70(6):1515-23. PubMed ID: 23382026
[TBL] [Abstract][Full Text] [Related]
18. Dynamics of 23Na during completely balanced steady-state free precession.
Kharrazian R; Jakob PM
J Magn Reson; 2006 Mar; 179(1):73-84. PubMed ID: 16337416
[TBL] [Abstract][Full Text] [Related]
19. Off-resonance effects in the transient response of SSFP sequences.
Ganter C
Magn Reson Med; 2004 Aug; 52(2):368-75. PubMed ID: 15282820
[TBL] [Abstract][Full Text] [Related]
20. Approximate Fourier domain expression for Bloch-Siegert shift.
Turk EA; Ider YZ; Ergun AS; Atalar E
Magn Reson Med; 2015 Jan; 73(1):117-25. PubMed ID: 24478164
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]