BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

105 related articles for article (PubMed ID: 16323155)

  • 1. A simple geometrical description of the TrueFISP ideal transient and steady-state signal.
    Schmitt P; Griswold MA; Gulani V; Haase A; Flentje M; Jakob PM
    Magn Reson Med; 2006 Jan; 55(1):177-86. PubMed ID: 16323155
    [TBL] [Abstract][Full Text] [Related]  

  • 2. On the use of steady-state signal equations for 2D TrueFISP imaging.
    Coolen BF; Heijman E; Nicolay K; Strijkers GJ
    Magn Reson Imaging; 2009 Jul; 27(6):815-22. PubMed ID: 19249169
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Inversion recovery TrueFISP: quantification of T(1), T(2), and spin density.
    Schmitt P; Griswold MA; Jakob PM; Kotas M; Gulani V; Flentje M; Haase A
    Magn Reson Med; 2004 Apr; 51(4):661-7. PubMed ID: 15065237
    [TBL] [Abstract][Full Text] [Related]  

  • 4. T-one insensitive steady state imaging: a framework for purely T2-weighted TrueFISP.
    Schmitt P; Jakob PM; Kotas M; Flentje M; Haase A; Griswold MA
    Magn Reson Med; 2012 Aug; 68(2):409-20. PubMed ID: 22131223
    [TBL] [Abstract][Full Text] [Related]  

  • 5. An analytical description of balanced steady-state free precession with finite radio-frequency excitation.
    Bieri O
    Magn Reson Med; 2011 Feb; 65(2):422-31. PubMed ID: 20859995
    [TBL] [Abstract][Full Text] [Related]  

  • 6. New insights into the mechanisms of signal formation in RF-spoiled gradient echo sequences.
    Denolin V; Azizieh C; Metens T
    Magn Reson Med; 2005 Oct; 54(4):937-54. PubMed ID: 16155898
    [TBL] [Abstract][Full Text] [Related]  

  • 7. On the transient phase of balanced SSFP sequences.
    Scheffler K
    Magn Reson Med; 2003 Apr; 49(4):781-3. PubMed ID: 12652552
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Fat attenuation using a dual steady-state balanced-SSFP sequence with periodically variable flip angles.
    Absil J; Denolin V; Metens T
    Magn Reson Med; 2006 Feb; 55(2):343-51. PubMed ID: 16402382
    [TBL] [Abstract][Full Text] [Related]  

  • 9. On flow effects in balanced steady-state free precession imaging: pictorial description, parameter dependence, and clinical implications.
    Markl M; Pelc NJ
    J Magn Reson Imaging; 2004 Oct; 20(4):697-705. PubMed ID: 15390233
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Optimization of RF excitation to maximize signal and T2 contrast of tissues with rapid transverse relaxation.
    Carl M; Bydder M; Du J; Takahashi A; Han E
    Magn Reson Med; 2010 Aug; 64(2):481-90. PubMed ID: 20665792
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Flow effects in balanced steady state free precession imaging.
    Markl M; Alley MT; Elkins CJ; Pelc NJ
    Magn Reson Med; 2003 Nov; 50(5):892-903. PubMed ID: 14586999
    [TBL] [Abstract][Full Text] [Related]  

  • 12. T2 measurement of the human myocardium using a T2-prepared transient-state TrueFISP sequence.
    Huang TY; Liu YJ; Stemmer A; Poncelet BP
    Magn Reson Med; 2007 May; 57(5):960-6. PubMed ID: 17457877
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effects of in-pulse transverse relaxation in 3D ultrashort echo time sequences: analytical derivation, comparison to numerical simulation and experimental application at 3T.
    Springer F; Steidle G; Martirosian P; Claussen CD; Schick F
    J Magn Reson; 2010 Sep; 206(1):88-96. PubMed ID: 20637661
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Reduction of transient signal oscillations in true-FISP using a linear flip angle series magnetization preparation.
    Deshpande VS; Chung YC; Zhang Q; Shea SM; Li D
    Magn Reson Med; 2003 Jan; 49(1):151-7. PubMed ID: 12509831
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Are TrueFISP images T2/T1-weighted?
    Huang TY; Huang IJ; Chen CY; Scheffler K; Chung HW; Cheng HC
    Magn Reson Med; 2002 Oct; 48(4):684-8. PubMed ID: 12353286
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Magnetization preparation during the steady state: fat-saturated 3D TrueFISP.
    Scheffler K; Heid O; Hennig J
    Magn Reson Med; 2001 Jun; 45(6):1075-80. PubMed ID: 11378886
    [TBL] [Abstract][Full Text] [Related]  

  • 17. B1+-mapping with the transient phase of unbalanced steady-state free precession.
    Ganter C; Settles M; Dregely I; Santini F; Scheffler K; Bieri O
    Magn Reson Med; 2013 Dec; 70(6):1515-23. PubMed ID: 23382026
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Dynamics of 23Na during completely balanced steady-state free precession.
    Kharrazian R; Jakob PM
    J Magn Reson; 2006 Mar; 179(1):73-84. PubMed ID: 16337416
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Off-resonance effects in the transient response of SSFP sequences.
    Ganter C
    Magn Reson Med; 2004 Aug; 52(2):368-75. PubMed ID: 15282820
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Approximate Fourier domain expression for Bloch-Siegert shift.
    Turk EA; Ider YZ; Ergun AS; Atalar E
    Magn Reson Med; 2015 Jan; 73(1):117-25. PubMed ID: 24478164
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.