110 related articles for article (PubMed ID: 1632946)
1. A lysine dehydrogenase-based electrode for biosensing of L-lysine.
Dempsey E; Wang J; Wollenberger U; Ozsoz M; Smyth MR
Biosens Bioelectron; 1992; 7(5):323-7. PubMed ID: 1632946
[TBL] [Abstract][Full Text] [Related]
2. Amperometric L-lysine enzyme electrodes based on carbon nanotube/redox polymer and graphene/carbon nanotube/redox polymer composites.
Kaçar C; Erden PE; Kılıç E
Anal Bioanal Chem; 2017 Apr; 409(11):2873-2883. PubMed ID: 28188350
[TBL] [Abstract][Full Text] [Related]
3. Amperometric enzyme electrode for theophylline.
Wang J; Dempsey E; Ozsoz M; Smyth MR
Analyst; 1991 Oct; 116(10):997-9. PubMed ID: 1801607
[TBL] [Abstract][Full Text] [Related]
4. Quantification of l-lysine in cheese by a novel amperometric biosensor.
Ciriello R; Cataldi TR; Crispo F; Guerrieri A
Food Chem; 2015 Feb; 169():13-9. PubMed ID: 25236192
[TBL] [Abstract][Full Text] [Related]
5. Immobilization of lysine oxidase on a gold-platinum nanoparticles modified Au electrode for detection of lysine.
Chauhan N; Narang J; Sunny ; Pundir CS
Enzyme Microb Technol; 2013 Apr; 52(4-5):265-71. PubMed ID: 23540929
[TBL] [Abstract][Full Text] [Related]
6. A novel amperometric biosensor based on a co-crosslinked L-lysine-α-oxidase/overoxidized polypyrrole bilayer for the highly selective determination of L-lysine.
Guerrieri A; Ciriello R; Cataldi TR
Anal Chim Acta; 2013 Sep; 795():52-9. PubMed ID: 23998537
[TBL] [Abstract][Full Text] [Related]
7. Amperometric biosensor based on diamond paste for the enantioanalysis of L-lysine.
Stefan-van Staden RI; Nejem RM; van Staden JF; Aboul-Enein HY
Biosens Bioelectron; 2012 May; 35(1):439-442. PubMed ID: 22417875
[TBL] [Abstract][Full Text] [Related]
8. A novel approach for the selective analysis of l-lysine in untreated human serum by a co-crosslinked l-lysine-α-oxidase/overoxidized polypyrrole bilayer based amperometric biosensor.
Ciriello R; De Gennaro F; Frascaro S; Guerrieri A
Bioelectrochemistry; 2018 Dec; 124():47-56. PubMed ID: 30007206
[TBL] [Abstract][Full Text] [Related]
9. Supramolecular-mediated immobilization of L-phenylalanine dehydrogenase on cyclodextrin-coated Au electrodes for biosensor applications.
Villalonga R; Fujii A; Shinohara H; Asano Y; Cao R; Tachibana S; Ortiz P
Biotechnol Lett; 2007 Mar; 29(3):447-52. PubMed ID: 17237972
[TBL] [Abstract][Full Text] [Related]
10. Immobilization of L-lysine alpha-oxidase on gold-mercaptopropionic acid self-assembled monolayer: preparation and electrochemical characterization.
Shervedani RK; Hemmatian Z; Hatefi-Mehrjardi A
Bioelectrochemistry; 2009 Jun; 75(2):124-9. PubMed ID: 19346168
[TBL] [Abstract][Full Text] [Related]
11. A new interference-free lysine biosensor using a non-conducting polymer film.
Kelly S; Curulli A; O'Sullivan C; Guilbault GG; Palleschi G
Biosens Bioelectron; 1998 Dec; 13(12):1245-50. PubMed ID: 9883557
[TBL] [Abstract][Full Text] [Related]
12. A novel potentiometric biosensor for determination of L-lysine in commercial pharmaceutical L-lysine tablet and capsule.
Yarar S; Karakuş E
Artif Cells Nanomed Biotechnol; 2016; 44(2):485-90. PubMed ID: 25271835
[TBL] [Abstract][Full Text] [Related]
13. L-amino acid biosensor based on L-amino acid oxidase immobilized onto NiHCNFe/c-MWCNT/PPy/GC electrode.
Lata S; Pundir CS
Int J Biol Macromol; 2013 Mar; 54():250-7. PubMed ID: 23237796
[TBL] [Abstract][Full Text] [Related]
14. An amperometric biosensor for L-glutamate determination prepared from L-glutamate oxidase immobilized in polypyrrole-polyvinylsulphonate film.
Şimşek Ş; Aynacı E; Arslan F
Artif Cells Nanomed Biotechnol; 2016; 44(1):356-61. PubMed ID: 25682838
[TBL] [Abstract][Full Text] [Related]
15. Chiral analysis of amino acids using electrochemical composite bienzyme biosensors.
Domínguez R; Serra B; Reviejo AJ; Pingarrón JM
Anal Biochem; 2001 Nov; 298(2):275-82. PubMed ID: 11700983
[TBL] [Abstract][Full Text] [Related]
16. Electropolymerised o-phenylenediamine film as means of immobilising lactate oxidase for a L-lactate biosensor.
Dempsey E; Wang J; Smyth MR
Talanta; 1993 Mar; 40(3):445-51. PubMed ID: 18965649
[TBL] [Abstract][Full Text] [Related]
17. Determination of lysine in pharmaceutical samples containing endogenous ammonium ions by using a lysine oxidase biosensor based on an all-solid-state potentiometric ammonium electrode.
Saurina J; Hernández-Cassou S; Alegret S; Fàbregas E
Biosens Bioelectron; 1999 Jan; 14(1):67-75. PubMed ID: 10028651
[TBL] [Abstract][Full Text] [Related]
18. An amperometric glutamate biosensor based on immobilization of glutamate oxidase onto carboxylated multiwalled carbon nanotubes/gold nanoparticles/chitosan composite film modified Au electrode.
Batra B; Pundir CS
Biosens Bioelectron; 2013 Sep; 47():496-501. PubMed ID: 23628843
[TBL] [Abstract][Full Text] [Related]
19. Electrocatalytic oxidation of NADH at electrogenerated NAD+ oxidation product immobilized onto multiwalled carbon nanotubes/ionic liquid nanocomposite: application to ethanol biosensing.
Teymourian H; Salimi A; Hallaj R
Talanta; 2012 Feb; 90():91-8. PubMed ID: 22340121
[TBL] [Abstract][Full Text] [Related]
20. Electrocatalytic detection of NADH and glycerol by NAD(+)-modified carbon electrodes.
Alvarez-González MI; Saidman SB; Lobo-Castañón MJ; Miranda-Ordieres AJ; Tuñón-Blanco P
Anal Chem; 2000 Feb; 72(3):520-7. PubMed ID: 10695137
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]