110 related articles for article (PubMed ID: 1632946)
21. An amperometric biosensor for glucose detection from glucose oxidase immobilized in polyaniline-polyvinylsulfonate-potassium ferricyanide film.
Arslan F; Beskan U
Artif Cells Nanomed Biotechnol; 2014 Aug; 42(4):284-8. PubMed ID: 23822885
[TBL] [Abstract][Full Text] [Related]
22. Amperometric lactate biosensor for flow injection analysis based on a screen-printed carbon electrode containing Meldola's Blue-Reinecke salt, coated with lactate dehydrogenase and NAD+.
Piano M; Serban S; Pittson R; Drago GA; Hart JP
Talanta; 2010 Jun; 82(1):34-7. PubMed ID: 20685431
[TBL] [Abstract][Full Text] [Related]
23. Sensitive determination of L-lysine with a new amperometric microbial biosensor based on Saccharomyces cerevisiae yeast cells.
Akyilmaz E; Erdoğan A; Oztürk R; Yaşa I
Biosens Bioelectron; 2007 Jan; 22(6):1055-60. PubMed ID: 16759846
[TBL] [Abstract][Full Text] [Related]
24. Urease-glutamic dehydrogenase biosensor for screening heavy metals in water and soil samples.
Rodriguez BB; Bolbot JA; Tothill IE
Anal Bioanal Chem; 2004 Sep; 380(2):284-92. PubMed ID: 15300352
[TBL] [Abstract][Full Text] [Related]
25. Development of biosensor based on immobilized L-glutamate oxidase for determination of monosodium glutamate in food.
Basu AK; Chattopadhyay P; Roychudhuri U; Chakraborty R
Indian J Exp Biol; 2006 May; 44(5):392-8. PubMed ID: 16708893
[TBL] [Abstract][Full Text] [Related]
26. Electrochemically platinized carbon paste enzyme electrodes: a new design of amperometric glucose biosensors.
Ming L; Xi X; Liu J
Biotechnol Lett; 2006 Sep; 28(17):1341-5. PubMed ID: 16820975
[TBL] [Abstract][Full Text] [Related]
27. Development of an Amperometric Biosensor Platform for the Combined Determination of L-Malic, Fumaric, and L-Aspartic Acid.
Röhlen DL; Pilas J; Schöning MJ; Selmer T
Appl Biochem Biotechnol; 2017 Oct; 183(2):566-581. PubMed ID: 28866798
[TBL] [Abstract][Full Text] [Related]
28. Determination of glutamic acid decarboxylase activity and inhibition by an H2O2-sensing glutamic acid oxidase biosensor.
Botrè C; Botrè F; Galli M; Lorenti G; Mazzei F; Porcelli F
Anal Biochem; 1992 Mar; 201(2):227-32. PubMed ID: 1352947
[TBL] [Abstract][Full Text] [Related]
29. Determination of L-glutamate and L-glutamine in pharmaceutical formulations by amperometric L-glutamate oxidase based enzyme sensors.
Botrè F; Botrè C; Lorenti G; Mazzei F; Porcelli F; Scibona G
J Pharm Biomed Anal; 1993 Aug; 11(8):679-86. PubMed ID: 7903052
[TBL] [Abstract][Full Text] [Related]
30. Determination of L-phenylalanine based on an NADH-detecting biosensor.
Huang T; Warsinke A; Kuwana T; Scheller FW
Anal Chem; 1998 Mar; 70(5):991-7. PubMed ID: 9511473
[TBL] [Abstract][Full Text] [Related]
31. Amperometric flow injection analysis of glucose using immobilized glucose oxidase on nano-composite carbon nanotubes-platinum nanoparticles carbon paste electrode.
Amatatongchai M; Sroysee W; Chairam S; Nacapricha D
Talanta; 2017 May; 166():420-427. PubMed ID: 28213255
[TBL] [Abstract][Full Text] [Related]
32. Robust l-malate bienzymatic biosensor to enable the on-site monitoring of malolactic fermentation of red wines.
Giménez-Gómez P; Gutiérrez-Capitán M; Capdevila F; Puig-Pujol A; Fernández-Sánchez C; Jiménez-Jorquera C
Anal Chim Acta; 2017 Feb; 954():105-113. PubMed ID: 28081804
[TBL] [Abstract][Full Text] [Related]
33. Optical enzyme sensor for determining L-lysine content using L-lysine oxidase from the rockfish Sebastes schlegeli.
Endo H; Hayashi Y; Kitani Y; Ren H; Hayashi T; Nagashima Y
Anal Bioanal Chem; 2008 Jun; 391(4):1255-61. PubMed ID: 18236032
[TBL] [Abstract][Full Text] [Related]
34. Allosteric Enzyme-Based Biosensors-Kinetic Behaviours of Immobilised L-Lysine-α-Oxidase from
Guerrieri A; Ciriello R; Bianco G; De Gennaro F; Frascaro S
Biosensors (Basel); 2020 Oct; 10(10):. PubMed ID: 33080859
[TBL] [Abstract][Full Text] [Related]
35. New amperometric biosensors based on diamond paste for the assay of L- and D-pipecolic acids in serum samples.
Stefan RI; Nejem RM; van Staden JF; Aboul-Enein HY
Prep Biochem Biotechnol; 2004 May; 34(2):135-43. PubMed ID: 15195708
[TBL] [Abstract][Full Text] [Related]
36. Implementation of a new integrated d-lactic acid biosensor in a semiautomatic FIA system for the simultaneous determination of lactic acid enantiomers. Application to the analysis of beer samples.
Vargas E; Ruiz MA; Campuzano S; González de Rivera G; López-Colino F; Reviejo AJ; Pingarrón JM
Talanta; 2016 May; 152():147-54. PubMed ID: 26992505
[TBL] [Abstract][Full Text] [Related]
37. Flow-injection amperometric determination of glucose using a biosensor based on immobilization of glucose oxidase onto Au seeds decorated on core Fe₃O₄ nanoparticles.
Samphao A; Butmee P; Jitcharoen J; Švorc Ľ; Raber G; Kalcher K
Talanta; 2015 Sep; 142():35-42. PubMed ID: 26003689
[TBL] [Abstract][Full Text] [Related]
38. Glucose biosensor based on the immobilization of glucose oxidase on electrochemically synthesized polypyrrole-poly(vinyl sulphonate) composite film by cross-linking with glutaraldehyde.
Colak O; Yaşar A; Cete S; Arslan F
Artif Cells Blood Substit Immobil Biotechnol; 2012 Oct; 40(5):354-61. PubMed ID: 22540929
[TBL] [Abstract][Full Text] [Related]
39. Monitoring glutamine in mammalian cell cultures using an amperometric biosensor.
Cattaneo MV; Luong JH; Mercille S
Biosens Bioelectron; 1992; 7(5):329-34. PubMed ID: 1352981
[TBL] [Abstract][Full Text] [Related]
40. Mediator-free amperometric determination of glucose based on direct electron transfer between glucose oxidase and an oxidized boron-doped diamond electrode.
Wu J; Qu Y
Anal Bioanal Chem; 2006 Aug; 385(7):1330-5. PubMed ID: 16773297
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]