198 related articles for article (PubMed ID: 16334836)
1. Calcium scoring of aortic valve calcification in aortic valve stenosis with a multislice computed tomography scanner: non-enhanced versus contrast-enhanced studies.
Mühlenbruch G; Wildberger JE; Koos R; Das M; Thomas C; Ruhl K; Niethammer M; Floh TG; Stanzel S; Günther RW; Mahnken AH
Acta Radiol; 2005 Oct; 46(6):561-6. PubMed ID: 16334836
[TBL] [Abstract][Full Text] [Related]
2. Quantification of aortic valve calcification using multislice spiral computed tomography: comparison with atomic absorption spectroscopy.
Koos R; Mahnken AH; Kühl HP; Mühlenbruch G; Mevissen V; Stork L; Dronskowski R; Langebartels G; Autschbach R; Ortlepp JR
Invest Radiol; 2006 May; 41(5):485-9. PubMed ID: 16625112
[TBL] [Abstract][Full Text] [Related]
3. Variability of aortic valve calcification measurement with multislice spiral computed tomography.
Ruhl KM; Das M; Koos R; Mühlenbruch G; Flohr TG; Wildberger JE; Günther RW; Mahnken AH
Invest Radiol; 2006 Apr; 41(4):370-3. PubMed ID: 16523019
[TBL] [Abstract][Full Text] [Related]
4. Coronary calcium scoring using 16-row multislice computed tomography: nonenhanced versus contrast-enhanced studies in vitro and in vivo.
Mühlenbruch G; Wildberger JE; Koos R; Das M; Flohr TG; Niethammer M; Weiss C; Günther RW; Mahnken AH
Invest Radiol; 2005 Mar; 40(3):148-54. PubMed ID: 15714089
[TBL] [Abstract][Full Text] [Related]
5. Aortic valve calcification scoring with computed tomography: impact of iterative reconstruction techniques.
Hinzpeter R; Weber L; Euler A; Kasel AM; Tanner FC; Alkadhi H; Eberhard M
Int J Cardiovasc Imaging; 2020 Aug; 36(8):1575-1581. PubMed ID: 32335821
[TBL] [Abstract][Full Text] [Related]
6. Electrocardiographically gated multi-detector row CT for assessment of valvular morphology and calcification in aortic stenosis.
Willmann JK; Weishaupt D; Lachat M; Kobza R; Roos JE; Seifert B; Lüscher TF; Marincek B; Hilfiker PR
Radiology; 2002 Oct; 225(1):120-8. PubMed ID: 12354994
[TBL] [Abstract][Full Text] [Related]
7. Practical determination of aortic valve calcium volume score on contrast-enhanced computed tomography prior to transcatheter aortic valve replacement and impact on paravalvular regurgitation: Elucidating optimal threshold cutoffs.
Bettinger N; Khalique OK; Krepp JM; Hamid NB; Bae DJ; Pulerwitz TC; Liao M; Hahn RT; Vahl TP; Nazif TM; George I; Leon MB; Einstein AJ; Kodali SK
J Cardiovasc Comput Tomogr; 2017; 11(4):302-308. PubMed ID: 28457950
[TBL] [Abstract][Full Text] [Related]
8. Reproducibility of aortic valve calcification scoring with computed tomography - An interplatform analysis.
Eberhard M; Hinzpeter R; Polacin M; Morsbach F; Maisano F; Nietlispach F; Nguyen-Kim TDL; Tanner FC; Alkadhi H
J Cardiovasc Comput Tomogr; 2019; 13(2):92-98. PubMed ID: 30665879
[TBL] [Abstract][Full Text] [Related]
9. Visual scoring of aortic valve calcifications on low-dose CT in lung cancer screening.
Zhu Y; Wang Y; Gioia WE; Yip R; Jirapatnakul AC; Chung MS; Yankelevitz DF; Henschke CI
Eur Radiol; 2020 May; 30(5):2658-2668. PubMed ID: 32040729
[TBL] [Abstract][Full Text] [Related]
10. Aortic valve calcification as quantified with multislice computed tomography predicts short-term clinical outcome in patients with asymptomatic aortic stenosis.
Feuchtner GM; Müller S; Grander W; Alber HF; Bartel T; Friedrich GJ; Reinthaler M; Pachinger O; zur Nedden D; Dichtl W
J Heart Valve Dis; 2006 Jul; 15(4):494-8. PubMed ID: 16901041
[TBL] [Abstract][Full Text] [Related]
11. Association between aortic valvular calcification and characteristics of the aortic valve in patients with bicuspid aortic valve stenosis.
Choi BH; Ko SM; Shin JK; Chee HK; Kim JS; Kim J
Acta Radiol; 2019 Apr; 60(4):468-477. PubMed ID: 30080100
[TBL] [Abstract][Full Text] [Related]
12. Assessment of aortic valve calcium load by multidetector computed tomography. Anatomical validation, impact of scanner settings and incremental diagnostic value.
Boulif J; Gerber B; Slimani A; Lazam S; de Meester C; Piérard S; Pasquet A; Pouleur AC; Vancraeynest D; El Khoury G; de Kerchove L; Noirhomme P; Vanoverschelde JL
J Cardiovasc Comput Tomogr; 2017; 11(5):360-366. PubMed ID: 28803719
[TBL] [Abstract][Full Text] [Related]
13. [Value of cardiac multislice spiral CT for the assessment of degenerative aortic stenosis: comparison with echocardiography].
Mahnken AH; Koos R; Wildberger JE; Stanzel S; Das M; Mühlenbruch G; Sinha AM; Günther RW
Rofo; 2004 Nov; 176(11):1582-8. PubMed ID: 15497076
[TBL] [Abstract][Full Text] [Related]
14. Quantifying Aortic Valve Calcification using Coronary Computed Tomography Angiography.
Alqahtani AM; Boczar KE; Kansal V; Chan K; Dwivedi G; Chow BJ
J Cardiovasc Comput Tomogr; 2017; 11(2):99-104. PubMed ID: 28209366
[TBL] [Abstract][Full Text] [Related]
15. Evaluation and clinical implications of aortic valve calcification measured by electron-beam computed tomography.
Messika-Zeitoun D; Aubry MC; Detaint D; Bielak LF; Peyser PA; Sheedy PF; Turner ST; Breen JF; Scott C; Tajik AJ; Enriquez-Sarano M
Circulation; 2004 Jul; 110(3):356-62. PubMed ID: 15249504
[TBL] [Abstract][Full Text] [Related]
16. Aortic root, not valve, calcification correlates with coronary artery calcification in patients with severe aortic stenosis: A two-center study.
Henein M; Hällgren P; Holmgren A; Sörensen K; Ibrahimi P; Kofoed KF; Larsen LH; Hassager C
Atherosclerosis; 2015 Dec; 243(2):631-7. PubMed ID: 26551591
[TBL] [Abstract][Full Text] [Related]
17. Comparison of aortic valve area measured by magnetic resonance imaging and dual-source computed tomography.
Bruder O; Jochims M; Hunold P; Jensen C; Forsting M; Sabin GV; Barkhausen J; Schlosser T
Acta Radiol; 2009 Jul; 50(6):645-51. PubMed ID: 19452337
[TBL] [Abstract][Full Text] [Related]
18. Influence of aortic valve leaflet calcification on dynamic aortic valve motion assessed by cardiac computed tomography.
Minami K; Yoneyama K; Izumo M; Suzuki K; Ogawa Y; Chikaraishi K; Ogawa Y; Kobayashi Y; Furukawa T; Tanabe Y; Akashi YJ
J Cardiovasc Comput Tomogr; 2016; 10(6):485-490. PubMed ID: 27597530
[TBL] [Abstract][Full Text] [Related]
19. Association between progression of aortic valve calcification and coronary calcification: assessment by electron beam tomography.
Takasu J; Shavelle DM; O'Brien KD; Babaei A; Rosales J; Mao S; Fischer H; Budoff MJ
Acad Radiol; 2005 Mar; 12(3):298-304. PubMed ID: 15766689
[TBL] [Abstract][Full Text] [Related]
20. Preliminary experience in the assessment of aortic valve calcification by ECG-gated multislice spiral computed tomography.
Koos R; Mahnken AH; Sinha AM; Wildberger JE; Hoffmann R; Kühl HP
Int J Cardiol; 2005 Jul; 102(2):195-200. PubMed ID: 15982484
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]