These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

203 related articles for article (PubMed ID: 16350377)

  • 21. An In-Vitro Study Comparing the GME Handling of Two Contemporary Oxygenators.
    Gisnarian CJ; Hedman A; Shann KG
    J Extra Corpor Technol; 2017 Dec; 49(4):262-272. PubMed ID: 29302117
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Quantification of Postmembrane Gaseous Microembolization During Venoarterial Extracorporeal Membrane Oxygenation.
    Jiao Y; Gipson KE; Bonde P; Mangi A; Hagberg R; Rosinski DJ; Gross JB; Schonberger RB
    ASAIO J; 2018; 64(1):31-37. PubMed ID: 28557862
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Retrospective Analysis of Air Handling by Contemporary Oxygenators in the Setting of Cardiac Surgery.
    Benstoem C; Bleilevens C; Borchard R; Stoppe C; Goetzenich A; Autschbach R; Breuer T
    Ann Thorac Cardiovasc Surg; 2018 Oct; 24(5):230-237. PubMed ID: 29998925
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Carbon Dioxide Flush of an Integrated Minimized Perfusion Circuit Prior to Priming Prevents Spontaneous Air Release Into the Arterial Line During Clinical Use.
    Stehouwer MC; de Vroege R; Hoohenkerk GJF; Hofman FN; Kelder JC; Buchner B; de Mol BA; Bruins P
    Artif Organs; 2017 Nov; 41(11):997-1003. PubMed ID: 28741663
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Evaluation of neonatal membrane oxygenators with respect to gaseous microemboli capture and transmembrane pressure gradients.
    Qiu F; Guan Y; Su X; Kunselman A; Undar A
    Artif Organs; 2010 Nov; 34(11):923-9. PubMed ID: 21092035
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Potential impact of oxygenators with venous air trap on air embolism in veno-arterial Extracorporeal Life Support.
    Born F; Khaladj N; Pichlmaier M; Schramm R; Hagl C; Guenther SP
    Technol Health Care; 2017; 25(1):111-121. PubMed ID: 27497463
    [TBL] [Abstract][Full Text] [Related]  

  • 27. An in vitro comparison of the ability of three commonly used pediatric cardiopulmonary bypass circuits to filter gaseous microemboli.
    Melchior RW; Rosenthal T; Glatz AC
    Perfusion; 2010 Jul; 25(4):255-63; discussion 265-6. PubMed ID: 20566585
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Product design and its relation to the generation of gaseous microemboli in the extracorporeal circuit.
    Servas FM
    Med Instrum; 1985; 19(2):63-6. PubMed ID: 4000008
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Dynamics of appearance and decay of gaseous microemboli during in vitro extracorporeal circulation.
    Harea GT; Karaliou V; Roberts TR; Choi JH; Beely BM; Cancio LC; Batchinsky AI
    Perfusion; 2022 Apr; 37(3):242-248. PubMed ID: 33567967
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Evaluation of membrane oxygenators and reservoirs in terms of capturing gaseous microemboli and pressure drops.
    Guan Y; Palanzo D; Kunselman A; Undar A
    Artif Organs; 2009 Nov; 33(11):1037-43. PubMed ID: 19874280
    [TBL] [Abstract][Full Text] [Related]  

  • 31. High risk of intraoperative awareness during cardiopulmonary bypass with isoflurane administration via diffusion membrane oxygenators.
    Philipp A; Wiesenack C; Behr R; Schmid FX; Birnbaum DE
    Perfusion; 2002 May; 17(3):175-8. PubMed ID: 12017384
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Evaluation of Combined Extracorporeal Life Support and Continuous Renal Replacement Therapy on Hemodynamic Performance and Gaseous Microemboli Handling Ability in a Simulated Neonatal ECLS System.
    Shank KR; Profeta E; Wang S; O'Connor C; Kunselman AR; Woitas K; Myers JL; Ündar A
    Artif Organs; 2018 Apr; 42(4):365-376. PubMed ID: 28940550
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Can an oxygenator design potentially contribute to air embolism in cardiopulmonary bypass? A novel method for the determination of the air removal capabilities of neonatal membrane oxygenators.
    De Somer F; Dierickx P; Dujardin D; Verdonck P; Van Nooten G
    Perfusion; 1998 May; 13(3):157-63. PubMed ID: 9638712
    [TBL] [Abstract][Full Text] [Related]  

  • 34. How effective are cardiopulmonary bypass circuits at removing gaseous microemboli?
    Jones TJ; Deal DD; Vernon JC; Blackburn N; Stump DA
    J Extra Corpor Technol; 2002 Mar; 34(1):34-9. PubMed ID: 11911627
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Gaseous microemboli: sources, causes, and clinical considerations.
    Kurusz M
    Med Instrum; 1985; 19(2):73-6. PubMed ID: 4000011
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Generation of microbubbles in extracorporeal life support and assessment of new elimination strategies.
    Born F; König F; Chen J; Günther S; Hagl C; Thierfelder N
    Artif Organs; 2020 Mar; 44(3):268-277. PubMed ID: 31408537
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Elimination of gaseous microemboli from cardiopulmonary bypass using hypobaric oxygenation.
    Gipson KE; Rosinski DJ; Schonberger RB; Kubera C; Mathew ES; Nichols F; Dyckman W; Courtin F; Sherburne B; Bordey AF; Gross JB
    Ann Thorac Surg; 2014 Mar; 97(3):879-86. PubMed ID: 24206970
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Measurement of gaseous microemboli in the prime before the initiation of cardiopulmonary bypass.
    Husebråten IM; Fiane AE; Ringdal MIL; Thiara APS
    Perfusion; 2018 Jan; 33(1):30-35. PubMed ID: 28784030
    [TBL] [Abstract][Full Text] [Related]  

  • 39. The detection of microemboli in the middle cerebral artery during cardiopulmonary bypass: a transcranial Doppler ultrasound investigation using membrane and bubble oxygenators.
    Padayachee TS; Parsons S; Theobold R; Linley J; Gosling RG; Deverall PB
    Ann Thorac Surg; 1987 Sep; 44(3):298-302. PubMed ID: 2957966
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Microemboli detection on extracorporeal bypass circuits.
    Lynch JE; Riley JB
    Perfusion; 2008 Jan; 23(1):23-32. PubMed ID: 18788214
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.