95 related articles for article (PubMed ID: 16360839)
1. HLA antibody identification with single antigen beads compared to conventional methods.
El-Awar N; Lee J; Terasaki PI
Hum Immunol; 2005 Sep; 66(9):989-97. PubMed ID: 16360839
[TBL] [Abstract][Full Text] [Related]
2. HLA class I epitopes: recognition of binding sites by mAbs or eluted alloantibody confirmed with single recombinant antigens.
El-Awar N; Lee JH; Tarsitani C; Terasaki PI
Hum Immunol; 2007 Mar; 68(3):170-80. PubMed ID: 17349872
[TBL] [Abstract][Full Text] [Related]
3. Luminex donor-specific crossmatches.
Billen EV; Voorter CE; Christiaans MH; van den Berg-Loonen EM
Tissue Antigens; 2008 Jun; 71(6):507-13. PubMed ID: 18380779
[TBL] [Abstract][Full Text] [Related]
4. Specific inhibition of HLA class I and II antibodies by soluble antigens--a method for the identification of antibody specificity in sera from alloimmunized individuals.
Sumitran-Karuppan S; Möller E
Transplantation; 1994 Sep; 58(6):713-9. PubMed ID: 7940692
[TBL] [Abstract][Full Text] [Related]
5. Prediction of crossmatch outcome of highly sensitized patients by single and/or multiple antigen bead luminex assay.
Vaidya S; Partlow D; Susskind B; Noor M; Barnes T; Gugliuzza K
Transplantation; 2006 Dec; 82(11):1524-8. PubMed ID: 17164726
[TBL] [Abstract][Full Text] [Related]
6. Human leukocyte antigen class II DQ alpha and beta epitopes identified from sera of kidney allograft recipients.
Deng CT; El-Awar N; Ozawa M; Cai J; Lachmann N; Terasaki PI
Transplantation; 2008 Aug; 86(3):452-9. PubMed ID: 18698250
[TBL] [Abstract][Full Text] [Related]
7. New HLA class I epitopes defined by murine monoclonal antibodies.
El-Awar N; Terasaki PI; Nguyen A; Lias M; Conger N
Hum Immunol; 2010 May; 71(5):456-61. PubMed ID: 20156507
[TBL] [Abstract][Full Text] [Related]
8. [C4d]FlowPRA screening--a specific assay for selective detection of complement-activating anti-HLA alloantibodies.
Wahrmann M; Exner M; Haidbauer B; Schillinger M; Regele H; Körmöczi G; Böhmig GA
Hum Immunol; 2005 May; 66(5):526-34. PubMed ID: 15935890
[TBL] [Abstract][Full Text] [Related]
9. Public epitope specificity of HLA class I antibodies induced by a failed kidney transplant: alloantibody characterization by flow cytometric techniques.
Piazza A; Poggi E; Ozzella G; Borrelli L; Monaco PI; Scornajenghi A; Tisone G; Adorno D
Transplantation; 2006 May; 81(9):1298-305. PubMed ID: 16699458
[TBL] [Abstract][Full Text] [Related]
10. Aortic valve allograft structural deterioration is associated with a subset of antibodies to human leukocyte antigens.
Dignan R; O'Brien M; Hogan P; Thornton A; Fowler K; Byrne D; Stephens F; Harrocks S
J Heart Valve Dis; 2003 May; 12(3):382-90; discussion 390-1. PubMed ID: 12803340
[TBL] [Abstract][Full Text] [Related]
11. Detection and analysis of HLA class I and class II specific alloantibodies in the sera of dialysis recipients waiting for a renal retransplantation.
Barocci S; Valente U; Nocera A
Clin Transplant; 2007; 21(1):47-56. PubMed ID: 17302591
[TBL] [Abstract][Full Text] [Related]
12. Utility of HLAMatchmaker and single-antigen HLA-antibody detection beads for identification of acceptable mismatches in highly sensitized patients awaiting kidney transplantation.
Goodman RS; Taylor CJ; O'Rourke CM; Lynch A; Bradley JA; Key T
Transplantation; 2006 May; 81(9):1331-6. PubMed ID: 16699463
[TBL] [Abstract][Full Text] [Related]
13. Human leukocyte antigen class I epitopes: update to 103 total epitopes, including the C locus.
El-Awar NR; Akaza T; Terasaki PI; Nguyen A
Transplantation; 2007 Aug; 84(4):532-40. PubMed ID: 17713439
[TBL] [Abstract][Full Text] [Related]
14. Single human leukocyte antigen flow cytometry beads for accurate identification of human leukocyte antigen antibody specificities.
Pei R; Lee JH; Shih NJ; Chen M; Terasaki PI
Transplantation; 2003 Jan; 75(1):43-9. PubMed ID: 12544869
[TBL] [Abstract][Full Text] [Related]
15. Reappraisal of HLA antibody analysis and crossmatching in kidney transplantation.
Lee PC; Ozawa M
Clin Transpl; 2007; ():219-26. PubMed ID: 18642453
[TBL] [Abstract][Full Text] [Related]
16. Surface antigen detection with non-fluorescent, antibody-coated microbeads: an alternative method compatible with conventional fluorochrome-based labeling.
Fortin M; Hugo P
Cytometry; 1999 May; 36(1):27-35. PubMed ID: 10331624
[TBL] [Abstract][Full Text] [Related]
17. Luminex technology for anti-HLA antibody screening: evaluation of performance and of impact on laboratory routine.
Colombo MB; Haworth SE; Poli F; Nocco A; Puglisi G; Innocente A; Serafini M; Messa P; Scalamogna M
Cytometry B Clin Cytom; 2007 Nov; 72(6):465-71. PubMed ID: 17397064
[TBL] [Abstract][Full Text] [Related]
18. Analysis of HLA class I specific antibodies in patients with failed allografts.
Mao Q; Terasaki PI; Cai J; El-Awar N; Rebellato L
Transplantation; 2007 Jan; 83(1):54-61. PubMed ID: 17220791
[TBL] [Abstract][Full Text] [Related]
19. Detection of HLA antibodies by using flow cytometry and latex beads coated with HLA antigens.
Moses LA; Stroncek DF; Cipolone KM; Marincola FM
Transfusion; 2000 Jul; 40(7):861-6. PubMed ID: 10924616
[TBL] [Abstract][Full Text] [Related]
20. HLA-DR antibody epitopes.
Cai J; Kohanof S; Terasaki PI
Clin Transpl; 2006; ():103-14. PubMed ID: 18365372
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]