These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

120 related articles for article (PubMed ID: 16366083)

  • 1. Extramedullary versus intramedullary tibial alignment guides for total knee arthroplasty.
    Rottman SJ; Dvorkin M; Gold D
    Orthopedics; 2005 Dec; 28(12):1445-8. PubMed ID: 16366083
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Extramedullary versus intramedullary tibial cutting guides in megaprosthetic total knee replacement.
    Karade V; Ravi B; Agarwal M
    J Orthop Surg Res; 2012 Oct; 7():33. PubMed ID: 23031403
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Computer-assisted techniques versus conventional guides for component alignment in total knee arthroplasty: a randomized controlled trial.
    Blakeney WG; Khan RJ; Wall SJ
    J Bone Joint Surg Am; 2011 Aug; 93(15):1377-84. PubMed ID: 21915542
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Intramedullary versus extramedullary tibial alignment guides in total knee arthroplasty.
    Yang SH; Liu TK
    J Formos Med Assoc; 1998 Aug; 97(8):564-8. PubMed ID: 9747068
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Intramedullary versus extramedullary alignment of the tibial component in the Triathlon knee.
    Cashman JP; Carty FL; Synnott K; Kenny PJ
    J Orthop Surg Res; 2011 Aug; 6():44. PubMed ID: 21854636
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Influence of intramedullary versus extramedullary alignment guides on final total knee arthroplasty component position: a radiographic analysis.
    Maestro A; Harwin SF; Sandoval MG; Vaquero DH; Murcia A
    J Arthroplasty; 1998 Aug; 13(5):552-8. PubMed ID: 9726321
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Extramedullary versus intramedullary tibial alignment technique in total knee arthroplasty: A meta-analysis of randomized controlled trials.
    Zeng HB; Ying XZ; Chen GJ; Yang XQ; Lin DD; Li ZJ; Liu HX
    Clinics (Sao Paulo); 2015 Oct; 70(10):714-9. PubMed ID: 26598086
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Intramedullary versus extramedullary tibial alignment systems in total knee arthroplasty.
    Dennis DA; Channer M; Susman MH; Stringer EA
    J Arthroplasty; 1993 Feb; 8(1):43-7. PubMed ID: 8436988
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Extramedullary versus intramedullary femoral alignment technique in total knee arthroplasty: a meta-analysis of randomized controlled trials.
    Tang Q; Shang P; Zheng G; Xu HZ; Liu HX
    J Orthop Surg Res; 2017 Jun; 12(1):82. PubMed ID: 28583144
    [TBL] [Abstract][Full Text] [Related]  

  • 10. An alternative method to create extramedullary references in total knee arthroplasty.
    Seo JG; Moon YW; Park SH; Shim JW; Kim SM
    Knee Surg Sports Traumatol Arthrosc; 2012 Jul; 20(7):1339-48. PubMed ID: 21918883
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of extramedullary versus intramedullary referencing for tibial component alignment in total ankle arthroplasty.
    Adams SB; Demetracopoulos CA; Viens NA; DeOrio JK; Easley ME; Queen RM; Nunley JA
    Foot Ankle Int; 2013 Dec; 34(12):1624-8. PubMed ID: 24043353
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Patient specific cutting guides versus an imageless, computer-assisted surgery system in total knee arthroplasty.
    Nam D; Maher PA; Rebolledo BJ; Nawabi DH; McLawhorn AS; Pearle AD
    Knee; 2013 Aug; 20(4):263-7. PubMed ID: 23347791
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The effect of ankle rotation on cutting of the tibia in total knee arthroplasty.
    Mizu-uchi H; Matsuda S; Miura H; Higaki H; Okazaki K; Iwamoto Y
    J Bone Joint Surg Am; 2006 Dec; 88(12):2632-6. PubMed ID: 17142413
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Intramedullary vs extramedullary femoral alignment guides: a 15-year follow-up of survivorship.
    Meding JB; Berend ME; Ritter MA; Galley MR; Malinzak RA
    J Arthroplasty; 2011 Jun; 26(4):591-5. PubMed ID: 21575792
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A novel extramedullary technique to guide femoral bone preparation in mobile unicompartmental knee arthroplasty based on tibial cut and overall alignment.
    Zhang Q; Wang W; Liu Z; Yue D; Cheng L; Wang B; Guo W
    J Orthop Surg Res; 2020 Mar; 15(1):92. PubMed ID: 32138759
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Extramedullary or intramedullary tibial alignment guides: a randomised, prospective trial of radiological alignment.
    Reed MR; Bliss W; Sher JL; Emmerson KP; Jones SM; Partington PF
    J Bone Joint Surg Br; 2002 Aug; 84(6):858-60. PubMed ID: 12211678
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Leg alignment and tibial slope after minimal invasive total knee arthroplasty: a prospective, randomized radiological study of intramedullary versus extramedullary tibial instrumentation.
    de Kroon KE; Houterman S; Janssen RP
    Knee; 2012 Aug; 19(4):270-4. PubMed ID: 21601462
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Tibial component alignment after total knee arthroplasty with intramedullary instrumentation: a prospective analysis.
    Talmo CT; Cooper AJ; Wuerz T; Lang JE; Bono JV
    J Arthroplasty; 2010 Dec; 25(8):1209-15. PubMed ID: 19879723
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Effectiveness comparison of different tibial intramedullary nail guide rod in total knee arthroplasty].
    Pei X; Huang L; Han G; Li R; Wang Z; Han X
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2013 Oct; 27(10):1162-6. PubMed ID: 24397123
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Comparison of Clinical Influence of Intramedullary versus Extramedullary Alignment Guides on Total Knee Arthroplasty].
    Bian YY; Weng XS; Lin J; Jin J; Qian WW; Zhai JL; Zhao LJ
    Zhongguo Yi Xue Ke Xue Yuan Xue Bao; 2015 Aug; 37(4):373-7. PubMed ID: 26564450
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.