  • 1. [Monitoring patients in the anesthesia recovery room. Continuous transcutaneous O2 and CO2 measurements].
    Kick O; Vandermeersch E; Mulier JP; Vermaut J; Van Aken H
    Anaesthesist; 1992 Jun; 41(6):331-4. PubMed ID: 1636916
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Development of a method of continuous monitoring of spontaneous respiration in the postoperative phase. 1. Normal values for cutaneous pO2- and pCO2-partial pressure together with pulse oximetry determined oxygen saturation in healthy young volunteers].
    Lehmann KA; Asoklis S; Grond S; Huttarsch H
    Anaesthesist; 1992 Mar; 41(3):121-9. PubMed ID: 1570883
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Transcutaneous measurement of gas exchange parameters in anesthesiologic practice].
    Khodas MIa; Charnaia MA; Vyzhigina MA
    Anesteziol Reanimatol; 1989; (4):12-4. PubMed ID: 2817490
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Pulse oximetry in very low birth weight infants with acute and chronic lung disease.
    Ramanathan R; Durand M; Larrazabal C
    Pediatrics; 1987 Apr; 79(4):612-7. PubMed ID: 2434913
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Continuous monitoring of spontaneous postoperative respiration. 3. The effect of amiphenazole on cutaneous oxygen and carbon dioxide partial pressure following gynecologic surgery under halothane anesthesia].
    Lehmann KA; Asoklis S; Grond S; Schroeder B
    Anaesthesist; 1993 Apr; 42(4):227-31. PubMed ID: 8488994
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [The accuracy of transcutaneous carbon dioxide monitoring during laparoscopic surgery].
    Nakamura A; Kanai M; Mizushima A; Katashima S; Miura K; Kawauchi Y; Kamiyama Y
    Masui; 2003 Aug; 52(8):846-51. PubMed ID: 13677274
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Airway pressure and transcutaneous O2 and CO2 partial pressure as monitoring measurements for high-frequency jet ventilation?].
    Kluge E; Börner U; Hempelmann G
    Anasth Intensivther Notfallmed; 1986 Aug; 21(4):198-202. PubMed ID: 3092694
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of a new combined transcutaneous measurement of PCO2/pulse oximetry oxygen saturation ear sensor in newborn patients.
    Bernet-Buettiker V; Ugarte MJ; Frey B; Hug MI; Baenziger O; Weiss M
    Pediatrics; 2005 Jan; 115(1):e64-8. PubMed ID: 15601814
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Neonatal pulse oximetry: accuracy and reliability.
    Hay WW; Brockway JM; Eyzaguirre M
    Pediatrics; 1989 May; 83(5):717-22. PubMed ID: 2717288
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Non-invasive (transcutaneous) monitoring of PCO2 (TcPCO2) in older adults.
    Janssens JP; Laszlo A; Uldry C; Titelion V; Picaud C; Michel JP
    Gerontology; 2005; 51(3):174-8. PubMed ID: 15832044
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Is continuous transcutaneous monitoring of PCO2 (TcPCO2) over 8 h reliable in adults?
    Janssens JP; Perrin E; Bennani I; de Muralt B; Titelion V; Picaud C
    Respir Med; 2001 May; 95(5):331-5. PubMed ID: 11392572
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Use of transcutaneous oxygen and carbon dioxide tensions for assessing indices of gas exchange during exercise testing.
    Carter R; Banham SW
    Respir Med; 2000 Apr; 94(4):350-5. PubMed ID: 10845433
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Comparison of the course of oxygen saturation and transcutaneous oxygen pressure in nonspecific inhalative provocation].
    Hoffarth HP; Reier W; Ulmer WT
    Pneumologie; 1990 Feb; 44 Suppl 1():364-5. PubMed ID: 2195519
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Transcutaneous monitoring of partial pressure of carbon dioxide in the elderly patient: a prospective, clinical comparison with end-tidal monitoring.
    Casati A; Squicciarini G; Malagutti G; Baciarello M; Putzu M; Fanelli A
    J Clin Anesth; 2006 Sep; 18(6):436-40. PubMed ID: 16980160
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Transcutaneous PCO2 determination in neonatology].
    Schultz MJ; de Kleine MJ; Koppe JG
    Tijdschr Kindergeneeskd; 1991 Apr; 59(2):44-50. PubMed ID: 2053109
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Invasive monitoring of arterial gases in intensive care. Indications, misuse and hazards].
    Chevrolet JC
    Schweiz Med Wochenschr; 1989 Mar; 119(11):335-40. PubMed ID: 2717894
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Transcutaneous oxygen monitoring in congenital diaphragmatic abnormalities.
    Gibbons M
    Nurs Crit Care; 1997; 2(3):132-7. PubMed ID: 9873314
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Invasive or transcutaneous measurements of oxygen saturation and blood gases? An evaluation of pulse oximetry and transcutaneous measurement of PO2 and PCO2 during rest and exercise].
    Stanghelle JK; Christensen CC; Haanaes OC
    Tidsskr Nor Laegeforen; 1993 Mar; 113(8):967-70. PubMed ID: 8470079
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Continuous pO2 and pCO2 measurement in brain tissue and cerebrovenous blood during different inspired oxygen settings. A porcine model.
    Roth S; Menzel M; Rieger A; Soukup J; Furka I; Mikó I; Hennig C; Peuse C; Radke J
    Acta Chir Hung; 1997; 36(1-4):289-91. PubMed ID: 9408378
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Interpretation of the tcPO2 curve in adult patients in an intensive care unit.
    Rooth G; Hedstrand U; Ogren C
    Birth Defects Orig Artic Ser; 1979; 15(4):557-71. PubMed ID: 534740
    [TBL] [Abstract][Full Text] [Related]  