BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

159 related articles for article (PubMed ID: 16376181)

  • 1. Implementation of a rapid inversion-prepared dual-contrast gradient echo sequence for quantitative dynamic contrast-enhanced magnetic resonance imaging of the human prostate.
    Prochnow D; Beyersdorff D; Warmuth C; Taupitz M; Gemeinhardt O; Lüdemann L
    Magn Reson Imaging; 2005 Dec; 23(10):983-90. PubMed ID: 16376181
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of normal prostate tissue, chronic prostatitis, and prostate cancer by quantitative perfusion analysis using a dynamic contrast-enhanced inversion-prepared dual-contrast gradient echo sequence.
    Franiel T; Lüdemann L; Rudolph B; Rehbein H; Staack A; Taupitz M; Prochnow D; Beyersdorff D
    Invest Radiol; 2008 Jul; 43(7):481-7. PubMed ID: 18580330
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Free-breathing quantitative dynamic contrast-enhanced magnetic resonance imaging in a rat liver tumor model using dynamic radial T(1) mapping.
    Braren R; Curcic J; Remmele S; Altomonte J; Ebert O; Rummeny EJ; Steingoetter A
    Invest Radiol; 2011 Oct; 46(10):624-31. PubMed ID: 21577121
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Simultaneous quantification of perfusion and permeability in the prostate using dynamic contrast-enhanced magnetic resonance imaging with an inversion-prepared dual-contrast sequence.
    Lüdemann L; Prochnow D; Rohlfing T; Franiel T; Warmuth C; Taupitz M; Rehbein H; Beyersdorff D
    Ann Biomed Eng; 2009 Apr; 37(4):749-62. PubMed ID: 19169821
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Differentiation of prostate cancer from normal prostate tissue in an animal model: conventional MRI and dynamic contrast-enhanced MRI.
    Gemeinhardt O; Lüdemann L; Prochnow D; Abramjuk C; Taupitz M; Hamm B; Beyersdorff D
    Rofo; 2005 Jul; 177(7):935-9. PubMed ID: 15973594
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Quantification of dynamic contrast-enhanced MR imaging of the knee in children with juvenile rheumatoid arthritis based on pharmacokinetic modeling.
    Workie DW; Dardzinski BJ; Graham TB; Laor T; Bommer WA; O'Brien KJ
    Magn Reson Imaging; 2004 Nov; 22(9):1201-10. PubMed ID: 15607091
    [TBL] [Abstract][Full Text] [Related]  

  • 7. T1-weighted fluid-attenuated inversion recovery and T1-weighted fast spin-echo contrast-enhanced imaging: a comparison in 20 patients with brain lesions.
    Al-Saeed O; Ismail M; Athyal RP; Rudwan M; Khafajee S
    J Med Imaging Radiat Oncol; 2009 Aug; 53(4):366-72. PubMed ID: 19695043
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Equilibrium signal intensity mapping, an MRI method for fast mapping of longitudinal relaxation rates and for image enhancement.
    Surányi P; Kiss P; Ruzsics B; Brott BC; Simor T; Elgavish GA
    Magn Reson Imaging; 2007 Jun; 25(5):641-51. PubMed ID: 17540275
    [TBL] [Abstract][Full Text] [Related]  

  • 9. MRI before and after external beam intensity-modulated radiotherapy of patients with prostate cancer: the feasibility of monitoring of radiation-induced tissue changes using a dynamic contrast-enhanced inversion-prepared dual-contrast gradient echo sequence.
    Franiel T; Lüdemann L; Taupitz M; Böhmer D; Beyersdorff D
    Radiother Oncol; 2009 Nov; 93(2):241-5. PubMed ID: 19748143
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Reproducibility of the aortic input function (AIF) derived from dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) of the kidneys in a volunteer study.
    Mendichovszky IA; Cutajar M; Gordon I
    Eur J Radiol; 2009 Sep; 71(3):576-81. PubMed ID: 19004588
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Analysis of prostate DCE-MRI: comparison of fast exchange limit and fast exchange regimen pharmacokinetic models in the discrimination of malignant from normal tissue.
    Lowry M; Zelhof B; Liney GP; Gibbs P; Pickles MD; Turnbull LW
    Invest Radiol; 2009 Sep; 44(9):577-84. PubMed ID: 19668002
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Usefulness of diffusion-weighted imaging and dynamic contrast-enhanced magnetic resonance imaging in the diagnosis of prostate transition-zone cancer.
    Yoshizako T; Wada A; Hayashi T; Uchida K; Sumura M; Uchida N; Kitagaki H; Igawa M
    Acta Radiol; 2008 Dec; 49(10):1207-13. PubMed ID: 19031184
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Misregistration artifacts in image-derived arterial input function in non-echo-planar imaging-based dynamic contrast-enhanced MRI.
    Kuribayashi H; Worthington PL; Bradley DP; Checkley DR; Tessier JJ; Waterton JC
    J Magn Reson Imaging; 2007 Jun; 25(6):1248-55. PubMed ID: 17520722
    [TBL] [Abstract][Full Text] [Related]  

  • 14. T2* effects in the dual-sequence method for high-dose first-pass myocardial perfusion.
    Gatehouse P; Lyne J; Smith G; Pennell D; Firmin D
    J Magn Reson Imaging; 2006 Nov; 24(5):1168-71. PubMed ID: 17031839
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Feature extraction and classification of dynamic contrast-enhanced T2*-weighted breast image data.
    Torheim G; Godtliebsen F; Axelson D; Kvistad KA; Haraldseth O; Rinck PA
    IEEE Trans Med Imaging; 2001 Dec; 20(12):1293-301. PubMed ID: 11811829
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Contrast-enhanced T1-weighted fluid-attenuated inversion-recovery BLADE magnetic resonance imaging of the brain: an alternative to spin-echo technique for detection of brain lesions in the unsedated pediatric patient?
    Alibek S; Adamietz B; Cavallaro A; Stemmer A; Anders K; Kramer M; Bautz W; Staatz G
    Acad Radiol; 2008 Aug; 15(8):986-95. PubMed ID: 18620119
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Quantification of perfusion and permeability in breast tumors with a deconvolution-based analysis of second-bolus T1-DCE data.
    Makkat S; Luypaert R; Sourbron S; Stadnik T; De Mey J
    J Magn Reson Imaging; 2007 Jun; 25(6):1159-67. PubMed ID: 17520720
    [TBL] [Abstract][Full Text] [Related]  

  • 18. 3 Tesla magnetic resonance imaging of the prostate with combined pelvic phased-array and endorectal coils; Initial experience(1).
    Bloch BN; Rofsky NM; Baroni RH; Marquis RP; Pedrosa I; Lenkinski RE
    Acad Radiol; 2004 Aug; 11(8):863-7. PubMed ID: 15288036
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Brain magnetic resonance imaging at 3 Tesla using BLADE compared with standard rectilinear data sampling.
    Wintersperger BJ; Runge VM; Biswas J; Nelson CB; Stemmer A; Simonetta AB; Reiser MF; Naul LG; Schoenberg SO
    Invest Radiol; 2006 Jul; 41(7):586-92. PubMed ID: 16772852
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Rat model of reperfused partial liver infarction: characterization with multiparametric magnetic resonance imaging, microangiography, and histomorphology.
    Wu X; Wang H; Chen F; Jin L; Li J; Feng Y; DeKeyzer F; Yu J; Marchal G; Ni Y
    Acta Radiol; 2009 Apr; 50(3):276-87. PubMed ID: 19160078
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.