  • 1. Calculations for the availability of photoneutron using synchrotron radiation.
    Asano Y; Kawashima Y
    Radiat Prot Dosimetry; 2005; 115(1-4):176-80. PubMed ID: 16381708
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Calculations of neutron and photon source terms and attenuation profiles for the generic design of the SPEAR3 storage ring shield.
    Rokni SH; Khater H; Liu JC; Mao S; Vincke H
    Radiat Prot Dosimetry; 2005; 115(1-4):200-6. PubMed ID: 16381712
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Beam dumps design and local radiation protection at TERA synchrotron.
    Porta A; Campi F; Agosteo S
    Radiat Prot Dosimetry; 2005; 115(1-4):222-6. PubMed ID: 16381716
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Shielding design of an underground experimental area at point 5 of the CERN Super Proton Synchrotron (SPS).
    Mueller MJ; Stevenson GR
    Radiat Prot Dosimetry; 2005; 115(1-4):181-6. PubMed ID: 16381709
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Shielding for the upgraded Duke Free Electron Laser Laboratory.
    Vylet V
    Radiat Prot Dosimetry; 2005; 115(1-4):207-11. PubMed ID: 16381713
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Induced radioactivity in the ESRF storage ring.
    Berkvens P
    Radiat Prot Dosimetry; 2005; 115(1-4):475-80. PubMed ID: 16381770
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Monte Carlo simulations for the design of the treatment rooms and synchrotron access mazes in the CNAO Hadrontherapy facility.
    Porta A; Agosteo S; Campi F
    Radiat Prot Dosimetry; 2005; 113(3):266-74. PubMed ID: 15713741
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The TRADE experiment: shielding calculations for the building hosting the subcritical system.
    Burn KW; Carta M; Casalini L; Kadi Y; Monti S; Nava E; Palomba M; Petrovich C; Picardi L; Rubbia C; Troiani F
    Radiat Prot Dosimetry; 2005; 115(1-4):187-94. PubMed ID: 16381710
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Radiation safety assessment of a system of small reactors for distributed energy.
    Odano N; Ishida T
    Radiat Prot Dosimetry; 2005; 115(1-4):95-9. PubMed ID: 16381690
    [TBL] [Abstract][Full Text] [Related]  

  • 10. MCNPX vs. DORT for SNS shielding design studies.
    Popova II
    Radiat Prot Dosimetry; 2005; 115(1-4):559-63. PubMed ID: 16381785
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Pressure vessel calculations for VVER-440 reactors.
    Hordósy G; Hegyi G; Keresztúri A; Maráczy C; Temesvári E; Vértes P; Zsolnay E
    Radiat Prot Dosimetry; 2005; 115(1-4):100-3. PubMed ID: 16381691
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The refined shielding design for the cyclotron room of the Buddhist Tzu Chi General Hospital.
    Sheu RD; Chen CC; Sheu RJ; Kao CH; Jiang SH
    Radiat Prot Dosimetry; 2005; 115(1-4):216-21. PubMed ID: 16381715
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Monte Carlo simulations for the shielding of the future high-intensity accelerator facility FAIR at GSI.
    Radon T; Gutermuth F; Fehrenbacher G
    Radiat Prot Dosimetry; 2005; 115(1-4):212-5. PubMed ID: 16381714
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Shielding design for the PANDA spectrometer at the Munich high-flux reactor FRM-II.
    Noack K; Pyka NM; Rogov A; Steichele E
    Radiat Prot Dosimetry; 2005; 115(1-4):262-7. PubMed ID: 16381725
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Radiation protection aspects of a 4 MW target.
    Agosteo S; Magistris M; Silari M
    Radiat Prot Dosimetry; 2005; 115(1-4):465-9. PubMed ID: 16381768
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of the neutron spectrum and dose assessment around the venus reactor.
    Coeck M; Vermeersch F; Vanhavere F
    Radiat Prot Dosimetry; 2005; 115(1-4):76-9. PubMed ID: 16381686
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Target station shielding issues at the spallation neutron source.
    Ferguson PD; Gallmeier FX; Iverson EB; Popova II
    Radiat Prot Dosimetry; 2005; 115(1-4):170-5. PubMed ID: 16381707
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Study of the neutron beam line shield design for JSNS.
    Kawai M; Saito K; Sanami T; Nakao N; Maekawa F
    Radiat Prot Dosimetry; 2005; 115(1-4):580-6. PubMed ID: 16381789
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Shielding variation effects for 250 MeV protons on tissue targets.
    Brandl A; Hranitzky C; Rollet S
    Radiat Prot Dosimetry; 2005; 115(1-4):195-9. PubMed ID: 16381711
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Measurement and calculation of the fast-neutron and photon spectra from the core boundary to the biological shielding in the WWER-1000 reactor model.
    Osmera B; Cvachovec F; Kyncl J; Smutný V
    Radiat Prot Dosimetry; 2005; 115(1-4):92-4. PubMed ID: 16381689
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]