426 related articles for article (PubMed ID: 16381749)
1. Analysis of shielding materials in a Compton spectrometer applied to x-ray tube quality control using Monte Carlo simulation.
Gallardo S; Ródenas J; Verdú G; Villaescusa JI
Radiat Prot Dosimetry; 2005; 115(1-4):375-9. PubMed ID: 16381749
[TBL] [Abstract][Full Text] [Related]
2. Monte carlo simulation of the compton scattering technique applied to characterize diagnostic x-ray spectra.
Gallardo S; Ródenas J; Verdú G
Med Phys; 2004 Jul; 31(7):2082-90. PubMed ID: 15305461
[TBL] [Abstract][Full Text] [Related]
3. Evaluation of transmission data of diagnostic X rays through concrete using Monte Carlo simulation.
Noto K; Koshida K; Iida H; Fukuda A
Radiat Prot Dosimetry; 2009 Feb; 133(3):144-52. PubMed ID: 19307234
[TBL] [Abstract][Full Text] [Related]
4. Tenth value layers for 60Co gamma rays and for 4, 6, 10, 15, and 18 MV x rays in concrete for beams of cone angles between 0 degrees and 14 degrees calculated by Monte Carlo simulation.
Jaradat AK; Biggs PJ
Health Phys; 2007 May; 92(5):456-63. PubMed ID: 17429304
[TBL] [Abstract][Full Text] [Related]
5. Shielding design for the PANDA spectrometer at the Munich high-flux reactor FRM-II.
Noack K; Pyka NM; Rogov A; Steichele E
Radiat Prot Dosimetry; 2005; 115(1-4):262-7. PubMed ID: 16381725
[TBL] [Abstract][Full Text] [Related]
6. Comparison of deterministic and Monte Carlo methods in shielding design.
Oliveira AD; Oliveira C
Radiat Prot Dosimetry; 2005; 115(1-4):254-7. PubMed ID: 16381723
[TBL] [Abstract][Full Text] [Related]
7. Monte Carlo simulation of a computed tomography x-ray tube.
Bazalova M; Verhaegen F
Phys Med Biol; 2007 Oct; 52(19):5945-55. PubMed ID: 17881811
[TBL] [Abstract][Full Text] [Related]
8. Dosimetric considerations on TEPC fluka-simulation and measurements.
Rollet S; Beck P; Ferrari A; Pelliccioni M; Autischer M
Radiat Prot Dosimetry; 2004; 110(1-4):833-7. PubMed ID: 15353755
[TBL] [Abstract][Full Text] [Related]
9. Development of a fast neutron spectrometer composed of silicon-SSD and position-sensitive proportional counters.
Matsumoto T; Harano H; Ito Y; Uritani A; Emi K; Kudo K
Radiat Prot Dosimetry; 2004; 110(1-4):223-6. PubMed ID: 15353649
[TBL] [Abstract][Full Text] [Related]
10. Assessment of mammography spectra using compton spectrometry techniques.
Burgos MC; Gallardo S; Puchades V; Verdú G; Ródenas J; Villaescusa JI
Radiat Prot Dosimetry; 2005; 116(1-4 Pt 2):627-30. PubMed ID: 16604714
[TBL] [Abstract][Full Text] [Related]
11. Non-destructive method of characterisation of radioactive waste containers using gamma spectroscopy and Monte Carlo techniques.
Ridikas D; Feray S; Cometto M; Damoy F
Radiat Prot Dosimetry; 2005; 115(1-4):113-6. PubMed ID: 16381694
[TBL] [Abstract][Full Text] [Related]
12. A study of neutron spectra from medical linear accelerators.
Facure A; Falcão RC; Silva AX; Crispim VR; Vitorelli JC
Appl Radiat Isot; 2005 Jan; 62(1):69-72. PubMed ID: 15498687
[TBL] [Abstract][Full Text] [Related]
13. Spectra of clinical CT scanners using a portable Compton spectrometer.
Duisterwinkel HA; van Abbema JK; van Goethem MJ; Kawachimaru R; Paganini L; van der Graaf ER; Brandenburg S
Med Phys; 2015 Apr; 42(4):1884-94. PubMed ID: 25832078
[TBL] [Abstract][Full Text] [Related]
14. Plastic materials as a radiation shield for beta- sources: a comparative study through Monte Carlo calculation.
Amato E; Lizio D
J Radiol Prot; 2009 Jun; 29(2):239-50. PubMed ID: 19454797
[TBL] [Abstract][Full Text] [Related]
15. Neutron shielding calculations in a proton therapy facility based on Monte Carlo simulations and analytical models: criterion for selecting the method of choice.
Titt U; Newhauser WD
Radiat Prot Dosimetry; 2005; 115(1-4):144-8. PubMed ID: 16381702
[TBL] [Abstract][Full Text] [Related]
16. Thimble ionization chambers in medium-energy x-ray beams and the role of constructive details of the central electrode: Monte Carlo simulations and measurements.
Ubrich F; Wulff J; Kranzer R; Zink K
Phys Med Biol; 2008 Sep; 53(18):4893-906. PubMed ID: 18711244
[TBL] [Abstract][Full Text] [Related]
17. Monte Carlo simulation of x-ray buildup factors of lead and its applications in shielding of diagnostic x-ray facilities.
Kharrati H; Agrebi A; Karaoui MK
Med Phys; 2007 Apr; 34(4):1398-404. PubMed ID: 17500471
[TBL] [Abstract][Full Text] [Related]
18. Determination of the weighted CT dose index in modern multi-detector CT scanners.
Perisinakis K; Damilakis J; Tzedakis A; Papadakis A; Theocharopoulos N; Gourtsoyiannis N
Phys Med Biol; 2007 Nov; 52(21):6485-95. PubMed ID: 17951857
[TBL] [Abstract][Full Text] [Related]
19. [The leakage radiation testing method for mammographic X-ray equipments].
Xia LJ; Wang JJ; Dupont B; Chen J
Zhongguo Yi Liao Qi Xie Za Zhi; 2006 Mar; 30(2):129-30. PubMed ID: 16830808
[TBL] [Abstract][Full Text] [Related]
20. Analysis of tenth-value-layers for common shielding materials for a robotically mounted stereotactic radiosurgery machine.
Rodgers JE
Health Phys; 2007 Apr; 92(4):379-86. PubMed ID: 17351503
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]