These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

128 related articles for article (PubMed ID: 16382616)

  • 1. Designs of a microwave TE011 mode cavity for a space borne H-maser.
    Hartnett JG; Tobar ME; Stanwix PL; Morikawa T; Cros D; Piquet O
    IEEE Trans Ultrason Ferroelectr Freq Control; 2005 Oct; 52(10):1638-43. PubMed ID: 16382616
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Designs of a miniaturized sapphire-loaded cavity for spaceborne hydrogen masers.
    Yang RF; Zhou TZ; Wang NR; Gao LS
    IEEE Trans Ultrason Ferroelectr Freq Control; 2010 Mar; 57(3):587-91. PubMed ID: 20211774
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Compact, high-Q, zero temperature coefficient, TE011 sapphire-rutile microwave distributed Bragg reflector resonators.
    Tobar ME; Cros D; Blondy P; Ivanov EN
    IEEE Trans Ultrason Ferroelectr Freq Control; 2001 May; 48(3):821-9. PubMed ID: 11381707
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A new method to reduce frequency-temperature coefficient of sapphire-loaded cavities for compact hydrogen masers.
    Yang RF; Zhou TZ; Chen HB; Wang NR; Gao LS
    IEEE Trans Ultrason Ferroelectr Freq Control; 2010 Mar; 57(3):583-6. PubMed ID: 20211773
    [TBL] [Abstract][Full Text] [Related]  

  • 5. High Q-factor Bragg-reflection sapphire-loaded cavity TE01delta mode resonators.
    Hartnett JG; Tobar ME; Cros D; Krupka J; Guillon P
    IEEE Trans Ultrason Ferroelectr Freq Control; 2002 Dec; 49(12):1628-34. PubMed ID: 12546144
    [TBL] [Abstract][Full Text] [Related]  

  • 6. EPR UNIFORM FIELD SIGNAL ENHANCEMENT BY DIELECTRIC TUBES IN CAVITIES.
    Hyde JS; Mett RR
    Appl Magn Reson; 2017 Dec; 48(11-12):1185-1204. PubMed ID: 29332997
    [TBL] [Abstract][Full Text] [Related]  

  • 7. High performance distributed Bragg reflector microwave resonator.
    Flory CA; Taber RC
    IEEE Trans Ultrason Ferroelectr Freq Control; 1997; 44(2):486-95. PubMed ID: 18244146
    [TBL] [Abstract][Full Text] [Related]  

  • 8. High Q-factor distributed bragg reflector resonators with reflectors of arbitrary thickness.
    Le Floch JM; Tobar ME; Cros D; Krupka J
    IEEE Trans Ultrason Ferroelectr Freq Control; 2007 Dec; 54(12):2689-95. PubMed ID: 18276575
    [TBL] [Abstract][Full Text] [Related]  

  • 9. General expressions for the coupling coefficient, quality and filling factors for a cavity with an insert using energy coupled mode theory.
    Elnaggar SY; Tervo R; Mattar SM
    J Magn Reson; 2014 May; 242():57-66. PubMed ID: 24607823
    [TBL] [Abstract][Full Text] [Related]  

  • 10. High-power solid-state sapphire whispering gallery mode maser.
    Creedon DL; Benmessaï K; Tobar ME; Hartnett JG; Bourgeois PY; Kersale Y; Le Floch JM; Giordano V
    IEEE Trans Ultrason Ferroelectr Freq Control; 2010 Mar; 57(3):641-6. PubMed ID: 20211783
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Distributed bragg reflector resonators with cylindrical symmetry and extremely high Q-factors.
    Tobar ME; le Floch JM; Cros D; Hartnett JG
    IEEE Trans Ultrason Ferroelectr Freq Control; 2005 Jan; 52(1):17-26. PubMed ID: 15742559
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A cryogenic open-cavity sapphire reference oscillator with low spurious mode density.
    Bourgeois PY; Kersalé Y; Bazin N; Chaubet M; Giordano V
    IEEE Trans Ultrason Ferroelectr Freq Control; 2004 Oct; 51(10):1232-9. PubMed ID: 15553506
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Enhanced magnetic Purcell effect in room-temperature masers.
    Breeze J; Tan KJ; Richards B; Sathian J; Oxborrow M; Alford NM
    Nat Commun; 2015 Feb; 6():6215. PubMed ID: 25698634
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Microwave oscillators incorporating high performance distributed Bragg reflector microwave resonators.
    Flory CA; Ko HL
    IEEE Trans Ultrason Ferroelectr Freq Control; 1998; 45(3):824-9. PubMed ID: 18244234
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Finite volume analysis of temperature effects induced by active MRI implants: 2. Defects on active MRI implants causing hot spots.
    Busch MH; Vollmann W; Grönemeyer DH
    Biomed Eng Online; 2006 May; 5():35. PubMed ID: 16729878
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Analysis of two stacked cylindrical dielectric resonators in a TE₁₀₂ microwave cavity for magnetic resonance spectroscopy.
    Mattar SM; Elnaggar SY
    J Magn Reson; 2011 Apr; 209(2):174-82. PubMed ID: 21300559
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An experimental study for the compact hydrogen maser with a TE111 septum cavity.
    Wang Q; Zhai Z; Zhang W; Lin C
    IEEE Trans Ultrason Ferroelectr Freq Control; 2000; 47(1):197-200. PubMed ID: 18238531
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Optimal design and validation of atom trapping and atomic storage time for active hydrogen maser.
    Liu S; Wang L; Wu X; Guo M; Chen X; Zhu H; Wang P; Wang B; Wang W
    Rev Sci Instrum; 2021 Feb; 92(2):023202. PubMed ID: 33648115
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Optimum design of a high-Q room- temperature whispering-gallery-mode X-band sapphire resonator.
    Hartnett JG; Tobar ME; Ivanov EN; Luiten AN
    IEEE Trans Ultrason Ferroelectr Freq Control; 2013 Jun; 60(6):1041-7. PubMed ID: 25004468
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Coupled modes, frequencies and fields of a dielectric resonator and a cavity using coupled mode theory.
    Elnaggar SY; Tervo R; Mattar SM
    J Magn Reson; 2014 Jan; 238():1-7. PubMed ID: 24246950
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.