These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
184 related articles for article (PubMed ID: 16386678)
1. Myocardial contrast echocardiography for the detection of coronary artery stenosis: a prospective multicenter study in comparison with single-photon emission computed tomography. Jeetley P; Hickman M; Kamp O; Lang RM; Thomas JD; Vannan MA; Vanoverschelde JL; van der Wouw PA; Senior R J Am Coll Cardiol; 2006 Jan; 47(1):141-5. PubMed ID: 16386678 [TBL] [Abstract][Full Text] [Related]
2. Comparison of sulfur hexafluoride microbubble (SonoVue)-enhanced myocardial contrast echocardiography with gated single-photon emission computed tomography for detection of significant coronary artery disease: a large European multicenter study. Senior R; Moreo A; Gaibazzi N; Agati L; Tiemann K; Shivalkar B; von Bardeleben S; Galiuto L; Lardoux H; Trocino G; Carrió I; Le Guludec D; Sambuceti G; Becher H; Colonna P; Ten Cate F; Bramucci E; Cohen A; Bezante G; Aggeli C; Kasprzak JD J Am Coll Cardiol; 2013 Oct; 62(15):1353-61. PubMed ID: 23770168 [TBL] [Abstract][Full Text] [Related]
3. Myocardial perfusion assessment in patients with medium probability of coronary artery disease and no prior myocardial infarction: comparison of myocardial contrast echocardiography with 99mTc single-photon emission computed tomography. Senior R; Lepper W; Pasquet A; Chung G; Hoffman R; Vanoverschelde JL; Cerqueira M; Kaul S Am Heart J; 2004 Jun; 147(6):1100-5. PubMed ID: 15199362 [TBL] [Abstract][Full Text] [Related]
4. Accelerated stress real-time myocardial contrast echocardiography for the detection of coronary artery disease: comparison with 99mTc single photon emission computed tomography. Lipiec P; Wejner-Mik P; Krzemińska-Pakuła M; Kuśmierek J; Płachcińska A; Szumiński R; Peruga JZ; Kasprzak JD J Am Soc Echocardiogr; 2008 Aug; 21(8):941-7. PubMed ID: 18385014 [TBL] [Abstract][Full Text] [Related]
5. Detection of coronary artery disease using real-time myocardial contrast echocardiography: a comparison with dual-isotope resting thallium-201/stress technectium-99m sestamibi single-photon emission computed tomography. Lin SL; Chiou KR; Huang WC; Peng NJ; Tsay DG; Liu CP Heart Vessels; 2006 Jul; 21(4):226-35. PubMed ID: 16865298 [TBL] [Abstract][Full Text] [Related]
6. Comparison of usefulness of dipyridamole stress myocardial contrast echocardiography to technetium-99m sestamibi single-photon emission computed tomography for detection of coronary artery disease (PB127 Multicenter Phase 2 Trial results). Wei K; Crouse L; Weiss J; Villanueva F; Schiller NB; Naqvi TZ; Siegel R; Monaghan M; Goldman J; Aggarwal P; Feigenbaum H; DeMaria A Am J Cardiol; 2003 Jun; 91(11):1293-8. PubMed ID: 12767419 [TBL] [Abstract][Full Text] [Related]
7. Long-Term Association of Dipyridamole Stress Myocardial Contrast Echocardiography versus Single-Photon Emission Computed Tomography with Clinical Outcomes in Patients with Known or Suspected Coronary Artery Disease. Karogiannis N; Vamvakidou A; Gurunathan S; Pabla J; Young G; Senior R J Am Soc Echocardiogr; 2018 Aug; 31(8):860-869. PubMed ID: 29861279 [TBL] [Abstract][Full Text] [Related]
8. Detection of residual infarct-related coronary artery stenosis and multivessel disease after thrombolysis: comparison between myocardial contrast echocardiography and single photon emission computed tomography. Dwivedi G; Janardhanan R; Hayat S; Senior R J Am Soc Echocardiogr; 2006 May; 19(5):546-51. PubMed ID: 16644439 [TBL] [Abstract][Full Text] [Related]
9. The value of quantitative real-time myocardial contrast echocardiography for detection of angiographically significant coronary artery disease. Li DY; Liang L; Xu TD; Zhang H; Pan DF; Chen JH; Chen J; Wang XP Clin Cardiol; 2013 Aug; 36(8):468-74. PubMed ID: 23754666 [TBL] [Abstract][Full Text] [Related]
10. Detection of coronary artery disease with myocardial contrast echocardiography: comparison with 99mTc-sestamibi single-photon emission computed tomography. Kaul S; Senior R; Dittrich H; Raval U; Khattar R; Lahiri A Circulation; 1997 Aug; 96(3):785-92. PubMed ID: 9264483 [TBL] [Abstract][Full Text] [Related]
11. Assessment of myocardial perfusion in patients with coronary artery disease. Comparison of myocardial contrast echocardiography and 99mTc MIBI single photon emission computed tomography. Olszowska M; Kostkiewicz M; Tracz W; Przewlocki T Int J Cardiol; 2003 Jul; 90(1):49-55. PubMed ID: 12821219 [TBL] [Abstract][Full Text] [Related]
12. Adenosine stress myocardial contrast echocardiography for the detection of coronary artery disease: a comparison with coronary angiography and cardiac magnetic resonance. Arnold JR; Karamitsos TD; Pegg TJ; Francis JM; Olszewski R; Searle N; Senior R; Neubauer S; Becher H; Selvanayagam JB JACC Cardiovasc Imaging; 2010 Sep; 3(9):934-43. PubMed ID: 20846628 [TBL] [Abstract][Full Text] [Related]
13. Myocardial contrast echocardiography in human beings: correlation of resting perfusion defects to sestamibi single photon emission computed tomography. Meza MF; Mobarek S; Sonnemaker R; Shuler S; Ramee SR; Collins TJ; White CJ; Aristizabal D; Murgo JP; Cheirif J Am Heart J; 1996 Sep; 132(3):528-35. PubMed ID: 8800021 [TBL] [Abstract][Full Text] [Related]
14. [Detection of coronary artery disease by adenosine triphosphate stress echocardiography: comparison with adenosine triphosphate stress thallium myocardial scintigraphy and coronary angiography]. Harada M; Okura K; Nishizawa S; Inoue T; Sakai H; Lee T; Sugiyama Y; Suzuki M; Hirai H; Yamaguchi T J Cardiol; 1998 Sep; 32(3):163-71. PubMed ID: 9783237 [TBL] [Abstract][Full Text] [Related]
15. Comparative accuracy of real-time myocardial contrast perfusion imaging and wall motion analysis during dobutamine stress echocardiography for the diagnosis of coronary artery disease. Elhendy A; O'Leary EL; Xie F; McGrain AC; Anderson JR; Porter TR J Am Coll Cardiol; 2004 Dec; 44(11):2185-91. PubMed ID: 15582317 [TBL] [Abstract][Full Text] [Related]
16. Non-invasive detection of coronary artery stenosis: a comparison among power-Doppler contrast echo, 99Tc-Sestamibi SPECT and echo wall-motion analysis. Rocchi G; Fallani F; Bracchetti G; Rapezzi C; Ferlito M; Levorato M; Reggiani LB; Branzi A Coron Artery Dis; 2003 May; 14(3):239-45. PubMed ID: 12702928 [TBL] [Abstract][Full Text] [Related]
17. Real-time myocardial perfusion imaging for pharmacologic stress testing: added value to single photon emission computed tomography. Korosoglou G; Dubart AE; DaSilva KG; Labadze N; Hardt S; Hansen A; Bekeredjian R; Zugck C; Zehelein J; Katus HA; Kuecherer H Am Heart J; 2006 Jan; 151(1):131-8. PubMed ID: 16368304 [TBL] [Abstract][Full Text] [Related]
18. Accuracy and feasibility of contrast echocardiography for detection of perfusion defects in routine practice: comparison with wall motion and technetium-99m sestamibi single-photon emission computed tomography. The Nycomed NC100100 Investigators. Marwick TH; Brunken R; Meland N; Brochet E; Baer FM; Binder T; Flachskampf F; Kamp O; Nienaber C; Nihoyannopoulos P; Pierard L; Vanoverschelde JL; van der Wouw P; Lindvall K J Am Coll Cardiol; 1998 Nov; 32(5):1260-9. PubMed ID: 9809934 [TBL] [Abstract][Full Text] [Related]
19. NC100100, a new echo contrast agent for the assessment of myocardial perfusion--safety and comparison with technetium-99m sestamibi single-photon emission computed tomography in a randomized multicenter study. Binder T; Assayag P; Baer F; Flachskampf F; Kamp O; Nienaber C; Nihoyannopoulos P; Piérard L; Steg G; Vanoverschelde JL; Van der Wouw P; Meland N; Marelli C; Lindvall K Clin Cardiol; 1999 Apr; 22(4):273-82. PubMed ID: 10198737 [TBL] [Abstract][Full Text] [Related]
20. Prognostic value of dipyridamole stress myocardial contrast echocardiography: comparison with single photon emission computed tomography. Dawson D; Kaul S; Peters D; Rinkevich D; Schnell G; Belcik JT; Wei K J Am Soc Echocardiogr; 2009 Aug; 22(8):954-60. PubMed ID: 19553084 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]