BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

142 related articles for article (PubMed ID: 16394609)

  • 1. Visualization of neointima formation by optical coherence tomography.
    Kume T; Akasaka T; Kawamoto T; Watanabe N; Toyota E; Sukmawan R; Sadahira Y; Yoshida K
    Int Heart J; 2005 Nov; 46(6):1133-6. PubMed ID: 16394609
    [TBL] [Abstract][Full Text] [Related]  

  • 2. In vivo comparison between optical coherence tomography and intravascular ultrasound for detecting small degrees of in-stent neointima after stent implantation.
    Suzuki Y; Ikeno F; Koizumi T; Tio F; Yeung AC; Yock PG; Fitzgerald PJ; Fearon WF
    JACC Cardiovasc Interv; 2008 Apr; 1(2):168-73. PubMed ID: 19463295
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Optical coherence tomography versus intravascular ultrasound to evaluate coronary artery disease and percutaneous coronary intervention.
    Bezerra HG; Attizzani GF; Sirbu V; Musumeci G; Lortkipanidze N; Fujino Y; Wang W; Nakamura S; Erglis A; Guagliumi G; Costa MA
    JACC Cardiovasc Interv; 2013 Mar; 6(3):228-36. PubMed ID: 23517833
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison between optical coherence tomography and intravascular ultrasound in detecting neointimal healing patterns after stent implantation.
    Kochman J; Pietrasik A; Rdzanak A; Jąkała J; Zasada W; Scibisz A; Kołtowski L; Proniewska K; Pociask E; Legutko J
    Kardiol Pol; 2014; 72(6):534-40. PubMed ID: 24293141
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation in 3 months duration of neointimal coverage after zotarolimus-eluting stent implantation by optical coherence tomography: the ENDEAVOR OCT trial.
    Kim JS; Jang IK; Fan C; Kim TH; Kim JS; Park SM; Choi EY; Lee SH; Ko YG; Choi D; Hong MK; Jang Y
    JACC Cardiovasc Interv; 2009 Dec; 2(12):1240-7. PubMed ID: 20129551
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Visualization of coronary atherosclerotic plaques in patients using optical coherence tomography: comparison with intravascular ultrasound.
    Jang IK; Bouma BE; Kang DH; Park SJ; Park SW; Seung KB; Choi KB; Shishkov M; Schlendorf K; Pomerantsev E; Houser SL; Aretz HT; Tearney GJ
    J Am Coll Cardiol; 2002 Feb; 39(4):604-9. PubMed ID: 11849858
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Intra-stent tissue evaluation within bare metal and drug-eluting stents > 3 years since implantation in patients with mild to moderate neointimal proliferation using optical coherence tomography and virtual histology intravascular ultrasound.
    Kitabata H; Loh JP; Pendyala LK; Omar A; Ota H; Minha S; Magalhaes MA; Torguson R; Chen F; Satler LF; Pichard AD; Waksman R
    Cardiovasc Revasc Med; 2014 Apr; 15(3):149-55. PubMed ID: 24767313
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Optical coherence tomography versus intravascular ultrasound in the evaluation of observer variability and reliability in the assessment of stent deployment: the OCTIVUS study.
    Magnus PC; Jayne JE; Garcia-Garcia HM; Swart M; van Es GA; Tijssen J; Kaplan AV
    Catheter Cardiovasc Interv; 2015 Aug; 86(2):229-35. PubMed ID: 25620044
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Impact of frequency-domain optical coherence tomography guidance for optimal coronary stent implantation in comparison with intravascular ultrasound guidance.
    Habara M; Nasu K; Terashima M; Kaneda H; Yokota D; Ko E; Ito T; Kurita T; Tanaka N; Kimura M; Ito T; Kinoshita Y; Tsuchikane E; Asakura K; Asakura Y; Katoh O; Suzuki T
    Circ Cardiovasc Interv; 2012 Apr; 5(2):193-201. PubMed ID: 22456026
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of Stent Expansion Guided by Optical Coherence Tomography Versus Intravascular Ultrasound: The ILUMIEN II Study (Observational Study of Optical Coherence Tomography [OCT] in Patients Undergoing Fractional Flow Reserve [FFR] and Percutaneous Coronary Intervention).
    Maehara A; Ben-Yehuda O; Ali Z; Wijns W; Bezerra HG; Shite J; Généreux P; Nichols M; Jenkins P; Witzenbichler B; Mintz GS; Stone GW
    JACC Cardiovasc Interv; 2015 Nov; 8(13):1704-14. PubMed ID: 26585621
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of optical coherence tomography and intravascular ultrasound for the assessment of in-stent tissue coverage after stent implantation.
    Capodanno D; Prati F; Pawlowsky T; Cera M; La Manna A; Albertucci M; Tamburino C
    EuroIntervention; 2009 Nov; 5(5):538-43. PubMed ID: 20142173
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The role of integrated backscatter intravascular ultrasound in characterizing bare metal and drug-eluting stent restenotic neointima as compared to optical coherence tomography.
    Sato K; Costopoulos C; Takebayashi H; Naganuma T; Miyazaki T; Goto K; Yamane H; Hagikura A; Kikuta Y; Taniguchi M; Hiramatsu S; Ito H; Colombo A; Haruta S
    J Cardiol; 2014 Dec; 64(6):488-95. PubMed ID: 24794757
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Drug-eluting stent implantation in patients with acute coronary syndrome - the Activity of Platelets after Inhibition and Cardiovascular Events: Optical Coherence Tomography (APICE OCT) study.
    Chieffo A; Buchanan GL; Parodi G; Versaci F; Bianchi RM; Valenti R; Saccà S; Mongiardo A; Span S; Migliorini A; Spaccarotella C; Reimers B; Antoniucci D; Indolfi C; Ferrari A; Maehara A; Mintz GS; Colombo A
    EuroIntervention; 2014 Dec; 10(8):916-23. PubMed ID: 24974806
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Combined use of optical coherence tomography and intravascular ultrasound imaging in patients undergoing coronary interventions for stent thrombosis.
    Alfonso F; Dutary J; Paulo M; Gonzalo N; Pérez-Vizcayno MJ; Jiménez-Quevedo P; Escaned J; Bañuelos C; Hernández R; Macaya C
    Heart; 2012 Aug; 98(16):1213-20. PubMed ID: 22826559
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Combined use of optical coherence tomography and intravascular ultrasound during percutaneous coronary intervention in patients with coronary artery disease].
    Hou JB; Meng LB; Jing SH; Han ZG; Yu H; Yu B
    Zhonghua Xin Xue Guan Bing Za Zhi; 2008 Nov; 36(11):980-4. PubMed ID: 19102909
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Histopathological validation of optical coherence tomography findings of the coronary arteries.
    Fujii K; Kawakami R; Hirota S
    J Cardiol; 2018 Sep; 72(3):179-185. PubMed ID: 29655510
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Ex vivo assessment of vascular response to coronary stents by optical frequency domain imaging.
    Nakano M; Vorpahl M; Otsuka F; Taniwaki M; Yazdani SK; Finn AV; Ladich ER; Kolodgie FD; Virmani R
    JACC Cardiovasc Imaging; 2012 Jan; 5(1):71-82. PubMed ID: 22239896
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Frequency-domain optical coherence tomography assessment of unprotected left main coronary artery disease-a comparison with intravascular ultrasound.
    Fujino Y; Bezerra HG; Attizzani GF; Wang W; Yamamoto H; Chamié D; Kanaya T; Mehanna E; Tahara S; Nakamura S; Costa MA
    Catheter Cardiovasc Interv; 2013 Sep; 82(3):E173-83. PubMed ID: 23359350
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Intravascular Images of Coronary Stenosis with Multiple Channels in a Patient with Antiphospholipid Syndrome: The Optical Coherence Tomography Findings.
    Ito S; Hasuo T
    Intern Med; 2017; 56(11):1351-1356. PubMed ID: 28566597
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Variability in quantitative and qualitative analysis of intravascular ultrasound and frequency domain optical coherence tomography.
    Abnousi F; Waseda K; Kume T; Otake H; Kawarada O; Yong CM; Fitzgerald PJ; Honda Y; Yeung AC; Fearon WF
    Catheter Cardiovasc Interv; 2013 Sep; 82(3):E192-9. PubMed ID: 23412754
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.