These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

93 related articles for article (PubMed ID: 16395237)

  • 1. Tracking technique of a micro guide wire in sequential fluorograms.
    Takemura A; Suzuki M; Harauchi H; Okumura Y
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2005 Dec; 61(12):1623-31. PubMed ID: 16395237
    [TBL] [Abstract][Full Text] [Related]  

  • 2. An algorithm for tracking microcatheters in fluoroscopy.
    Takemura A; Hoffmann KR; Suzuki M; Wang Z; Rangwala HS; Harauchi H; Rudin S; Umeda T
    J Digit Imaging; 2008 Mar; 21(1):99-108. PubMed ID: 17318702
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Guide-wire tracking during endovascular interventions.
    Baert SA; Viergever MA; Niessen WJ
    IEEE Trans Med Imaging; 2003 Aug; 22(8):965-72. PubMed ID: 12906251
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Endpoint localization in guide wire tracking during endovascular interventions.
    Baert SA; van Walsum T; Niessen WJ
    Acad Radiol; 2003 Dec; 10(12):1424-32. PubMed ID: 14697010
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Guide wire reconstruction and visualization in 3DRA using monoplane fluoroscopic imaging.
    van Walsum T; Baert SA; Niessen WJ
    IEEE Trans Med Imaging; 2005 May; 24(5):612-23. PubMed ID: 15889549
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Three-dimensional guide-wire reconstruction from biplane image sequences for integrated display in 3-D vasculature.
    Baert SA; van de Kraats EB; van Walsum T; Viergever MA; Niessen WJ
    IEEE Trans Med Imaging; 2003 Oct; 22(10):1252-8. PubMed ID: 14552579
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A machine learning approach for deformable guide-wire tracking in fluoroscopic sequences.
    Pauly O; Heibel H; Navab N
    Med Image Comput Comput Assist Interv; 2010; 13(Pt 3):343-50. PubMed ID: 20879418
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Towards real time guide wire shape extraction in fluoroscopic sequences: A two phase deep learning scheme to extract sparse curvilinear structures.
    Chen K; Qin W; Xie Y; Zhou S
    Comput Med Imaging Graph; 2021 Dec; 94():101989. PubMed ID: 34741846
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A method for determining the modulation transfer function from thick microwire profiles measured with x-ray microcomputed tomography.
    Nakaya Y; Kawata Y; Niki N; Umetatni K; Ohmatsu H; Moriyama N
    Med Phys; 2012 Jul; 39(7):4347-64. PubMed ID: 22830768
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Guide-wire detecting using a modified cascade classifier in interventional radiology.
    Li Wang ; Xiao-Liang Xie ; Zhan-Jie Gao ; Gui-Bin Bian ; Zeng-Guang Hou
    Annu Int Conf IEEE Eng Med Biol Soc; 2016 Aug; 2016():1240-1243. PubMed ID: 28268549
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Vascular guide wire navigation with a magnetic guidance system: experimental results in a phantom.
    Schiemann M; Killmann R; Kleen M; Abolmaali N; Finney J; Vogl TJ
    Radiology; 2004 Aug; 232(2):475-81. PubMed ID: 15215549
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Multiple template-based fluoroscopic tracking of lung tumor mass without implanted fiducial markers.
    Cui Y; Dy JG; Sharp GC; Alexander B; Jiang SB
    Phys Med Biol; 2007 Oct; 52(20):6229-42. PubMed ID: 17921582
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Real Time 3D Representation and Tracking of Guidewire for Image Guided Cardiovascular Interventions.
    Mehmood R; Iqbal N; Tahir A; Riaz MM; Nawaz R
    Adv Exp Med Biol; 2017; 989():165-176. PubMed ID: 28971425
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Feasibility of stent-graft placement with real-time MR fluoroscopy in a nonrigid aortic phantom.
    Attia C; Abdulrazzaq S; Huet L; Saint-James H; Beuf O; Farhat F; Douek P
    J Vasc Interv Radiol; 2008 Sep; 19(9):1354-60. PubMed ID: 18725099
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Use of internal coils for independent and direct MR imaging-guided endovascular device tracking.
    Omary RA; Green JD; Fang WS; Viohl I; Finn JP; Li D
    J Vasc Interv Radiol; 2003 Feb; 14(2 Pt 1):247-54. PubMed ID: 12582194
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Quantitative image quality evaluation of pixel-binning in a flat-panel detector for x-ray fluoroscopy.
    Srinivas Y; Wilson DL
    Med Phys; 2004 Jan; 31(1):131-41. PubMed ID: 14761029
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Interventional tool tracking using discrete optimization.
    Heibel H; Glocker B; Groher M; Pfister M; Navab N
    IEEE Trans Med Imaging; 2013 Mar; 32(3):544-55. PubMed ID: 23232412
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Suitability of the Cordis Stabilizer marker guide wire for quantitative coronary angiography calibration: an in vitro and in vivo study.
    Koning G; Hekking E; Kemppainen JS; Richardson GA; Rothman MT; Reiber JH
    Catheter Cardiovasc Interv; 2001 Mar; 52(3):334-41. PubMed ID: 11246248
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A key-point based real-time tracking of lung tumor in x-ray image sequence by using difference of Gaussians filtering and optical flow.
    Ichiji K; Yoshida Y; Homma N; Zhang X; Bukovsky I; Takai Y; Yoshizawa M
    Phys Med Biol; 2018 Sep; 63(18):185007. PubMed ID: 30109995
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Time-delayed summation as a means of improving resolution on fast rotating computed tomography systems.
    Nowak T; Hupfer M; Althoff F; Brauweiler R; Eisa F; Steiding C; Kalender WA
    Med Phys; 2012 Apr; 39(4):2249-60. PubMed ID: 22482646
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.