189 related articles for article (PubMed ID: 16401993)
1. A case of transient bioprosthetic valve regurgitation and hemolysis devoloping early after surgery using Carpentier-Edwards valve.
Sezai A; Shiono M; Hata M; Saito A; Hattori T; Wakui S; Soeda M; Kasamaki Y; Tokai K; Saito S; Negishi N; Sezai Y
Ann Thorac Cardiovasc Surg; 2005 Dec; 11(6):413-5. PubMed ID: 16401993
[TBL] [Abstract][Full Text] [Related]
2. Long-lasting durability of Carpentier-Edwards pericardial bovine bioprosthesis in mitral position - a case report of unfavourable post redo valve surgery course.
Luczak K; Piestrzeniewicz K; Maciejewski M; Walczak A; Jaszewski R; Ostrowski S; Drozdz J
Kardiol Pol; 2010 Jul; 68(7):806-8; discussion 809. PubMed ID: 20648442
[TBL] [Abstract][Full Text] [Related]
3. [Findings of the Carpentier-Edwards porcine bioprosthesis in the mitral position with PTF in the 16th post-operative year].
Matsuzaki K; Koishizawa T; Hiramatsu Y
Kyobu Geka; 1997 Oct; 50(11):950-3. PubMed ID: 9330518
[TBL] [Abstract][Full Text] [Related]
4. [A case report: Carpentier-Edwards porcine bioprosthesis malfunction due to the stent dehiscence at 17 years after the implantation in the mitral position].
Hayashi K; Nakano H; Sakamoto T; Okamura H
Kyobu Geka; 2000 Jan; 53(1):79-82. PubMed ID: 10639799
[TBL] [Abstract][Full Text] [Related]
5. [Effect of valve type and valve function on chronic intravascular hemolysis after alloprosthetic mitral and aortic valve replacement].
Horstkotte D; Aul C; Seipel L; Körfer R; Budde T; Schulte HD; Bircks W; Loogen F
Z Kardiol; 1983 Feb; 72(2):119-31. PubMed ID: 6845808
[TBL] [Abstract][Full Text] [Related]
6. [Re-operation of a mitral porcine bioprosthesis 22-years after implantation].
Soeda M; Hata H; Iida M; Kimura H
Kyobu Geka; 2009 Feb; 62(2):149-51. PubMed ID: 19202937
[TBL] [Abstract][Full Text] [Related]
7. LDH levels and left atrial ultrastructural chances in patients with mitral paraprosthetic regurgitation.
Mansuroğlu D; Omeroğlu SN; Izgi A; Ercan F; Yaymaci B; Başaran Y; Yakut C
J Card Surg; 2005; 20(3):229-33. PubMed ID: 15854083
[TBL] [Abstract][Full Text] [Related]
8. Re-do mitral valve replacement using the valve-on-valve technique: a case report.
Tamura Y; Kawata T; Kameda Y; Taniguchi S
Ann Thorac Cardiovasc Surg; 2005 Apr; 11(2):125-7. PubMed ID: 15900246
[TBL] [Abstract][Full Text] [Related]
9. [Valve-in-valve replacement of primary tissue valve failure of bovine pericardial valve minor].
Tateishi M; Koide M; Kunii Y; Watanabe K; Ohsawa M
Kyobu Geka; 2006 Jan; 59(1):61-4. PubMed ID: 16440687
[TBL] [Abstract][Full Text] [Related]
10. Mechanism of hemolysis after mitral valve repair and new surgical management: prosthetic annuloplasty ring covered with autologous pericardium.
Ishibashi N; Kasegawa H; Koyanagi T; Ida T
J Heart Valve Dis; 2005 Sep; 14(5):588-91. PubMed ID: 16245496
[TBL] [Abstract][Full Text] [Related]
11. [A report of two cases of Carpentier-Edwards pericardial mitral valve malfunction due to neointimal overgrowth expanding to valve cusps].
Sudo K; Sakai A; Koide M; Abe M; Kodera K; Oosawa M
Nihon Kyobu Geka Gakkai Zasshi; 1997 Sep; 45(9):1568-71. PubMed ID: 9341260
[TBL] [Abstract][Full Text] [Related]
12. Examination of hemolytic potential with the On-X(R) prosthetic heart valve.
Birnbaum D; Laczkovics A; Heidt M; Oelert H; Laufer G; Greve H; Pomar JL; Mohr F; Haverich A; Regensburger D
J Heart Valve Dis; 2000 Jan; 9(1):142-5. PubMed ID: 10678387
[TBL] [Abstract][Full Text] [Related]
13. [Stenosis of Carpentier-Edwards pericardial bioprosthesis in the tricuspid position caused by adhesion of native valve cusps to the bioprosthesis].
Nemoto S; Sakai A; Sudoh K; Kodera K; Abe M; Lim ZB; Oosawa M
Kyobu Geka; 1997 Nov; 50(12):1049-51. PubMed ID: 9388354
[TBL] [Abstract][Full Text] [Related]
14. Serial Doppler echocardiographic evaluation of Carpentier-Edwards pericardial valve dysfunction: comparison with Ionescu-Shiley valve.
Kobayashi Y; Nagata S; Eishi K; Nakano K; Miyatake K
Am Heart J; 1998 Jun; 135(6 Pt 1):1086-92. PubMed ID: 9630116
[TBL] [Abstract][Full Text] [Related]
15. [A case report on prosthetic valve dysfunction of the Carpentier-Edwards pericardial bioprosthesis in the tricuspid position associated with remarkable hypoproteinemia].
Hirai M; Maki S; Yasuda T; Kondo M
Kyobu Geka; 1997 Aug; 50(9):771-5. PubMed ID: 9259139
[TBL] [Abstract][Full Text] [Related]
16. [Emergent mitral valve replacement in the second trimester of pregnancy].
Sudoh Y; Takahara Y; Sunazawa T; Satoh T; Ishikawa H
Nihon Kyobu Geka Gakkai Zasshi; 1997 Jul; 45(7):1034-8. PubMed ID: 9256646
[TBL] [Abstract][Full Text] [Related]
17. Prognosis after aortic valve replacement with the Carpentier-Edwards pericardial valve: use of microsimulation.
Puvimanasinghe JP; Takkenberg JJ; Eijkemans MJ; Steyerberg EW; van Herwerden LA; Grunkemeier GL; Habbema JD; Bogers AJ
Ann Thorac Surg; 2005 Sep; 80(3):825-31. PubMed ID: 16122436
[TBL] [Abstract][Full Text] [Related]
18. Prosthetic mitral leaflet malfunction due to inappropriate size of implant.
Ng YT; Chung PC; Lau WM
Acta Anaesthesiol Taiwan; 2008 Jun; 46(2):76-9. PubMed ID: 18593653
[TBL] [Abstract][Full Text] [Related]
19. Aortic and mitral valve replacement in children: is there any role for biologic and bioprosthetic substitutes?
Alsoufi B; Manlhiot C; McCrindle BW; Canver CC; Sallehuddin A; Al-Oufi S; Joufan M; Al-Halees Z
Eur J Cardiothorac Surg; 2009 Jul; 36(1):84-90; discussion 90. PubMed ID: 19369085
[TBL] [Abstract][Full Text] [Related]
20. Acute bioprosthetic thrombosis immediately after aortic valve replacement.
Patanè F; Sansone F; Campanella A; Asteggiano F; Rinaldi M
J Cardiovasc Med (Hagerstown); 2009 Feb; 10(2):167-9. PubMed ID: 19194176
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]