  • 1. Tracking endoscopic instruments without localizer: image analysis-based approach.
    Tonet O; Ramesh TU; Megali G; Dario P
    Stud Health Technol Inform; 2006; 119():544-9. PubMed ID: 16404118
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Tracking endoscopic instruments without a localizer: a shape-analysis-based approach.
    Tonet O; Thoranaghatte RU; Megali G; Dario P
    Comput Aided Surg; 2007 Jan; 12(1):35-42. PubMed ID: 17364657
    [TBL] [Abstract][Full Text] [Related]  

  • 3. An integrated approach to endoscopic instrument tracking for augmented reality applications in surgical simulation training.
    Loukas C; Lahanas V; Georgiou E
    Int J Med Robot; 2013 Dec; 9(4):e34-51. PubMed ID: 23355307
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Videoendoscopic distortion correction and its application to virtual guidance of endoscopy.
    Helferty JP; Zhang C; McLennan G; Higgins WE
    IEEE Trans Med Imaging; 2001 Jul; 20(7):605-17. PubMed ID: 11465467
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Robust registration procedures for endoscopic imaging.
    Konen W; Tombrock S; Scholz M
    Med Image Anal; 2007 Dec; 11(6):526-39. PubMed ID: 17584520
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Development of a camera model and calibration procedure for oblique-viewing endoscopes.
    Yamaguchi T; Nakamoto M; Sato Y; Konishi K; Hashizume M; Sugano N; Yoshikawa H; Tamura S
    Comput Aided Surg; 2004; 9(5):203-14. PubMed ID: 16192062
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Augmented reality endoscopic system (ARES): preliminary results.
    Caversaccio M; Garcia Giraldez J; Thoranaghatte R; Zheng G; Eggli P; Nolte LP; Gonzalez Ballester MA
    Rhinology; 2008 Jun; 46(2):156-8. PubMed ID: 18575020
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A full geometric and photometric calibration method for oblique-viewing endoscopes.
    Wu C; Jaramaz B; Narasimhan SG
    Comput Aided Surg; 2010; 15(1-3):19-31. PubMed ID: 20433318
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The VN project: endoscopic image processing for neurosurgery.
    Konen W; Scholz M; Tombrock S
    Comput Aided Surg; 1998; 3(3):144-8. PubMed ID: 9888201
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Augmented reality during robot-assisted laparoscopic partial nephrectomy: toward real-time 3D-CT to stereoscopic video registration.
    Su LM; Vagvolgyi BP; Agarwal R; Reiley CE; Taylor RH; Hager GD
    Urology; 2009 Apr; 73(4):896-900. PubMed ID: 19193404
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Real-time markerless tracking for augmented reality: the virtual visual servoing framework.
    Comport AI; Marchand E; Pressigout M; Chaumette F
    IEEE Trans Vis Comput Graph; 2006; 12(4):615-28. PubMed ID: 16805268
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Clinical applications of commercially available video recording and monitoring systems: inexpensive, high-quality video recording and monitoring systems for endoscopy and microsurgery.
    Tsunoda K; Tsunoda A; Ishimoto S; Kimura S
    Surg Technol Int; 2006; 15():41-3. PubMed ID: 17029160
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Selective image similarity measure for bronchoscope tracking based on image registration.
    Deguchi D; Mori K; Feuerstein M; Kitasaka T; Maurer CR; Suenaga Y; Takabatake H; Mori M; Natori H
    Med Image Anal; 2009 Aug; 13(4):621-33. PubMed ID: 19592291
    [TBL] [Abstract][Full Text] [Related]  

  • 14. MonoSLAM: real-time single camera SLAM.
    Davison AJ; Reid ID; Molton ND; Stasse O
    IEEE Trans Pattern Anal Mach Intell; 2007 Jun; 29(6):1052-67. PubMed ID: 17431302
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Computation of gaze orientation under unrestrained head movements.
    Ronsse R; White O; Lefèvre P
    J Neurosci Methods; 2007 Jan; 159(1):158-69. PubMed ID: 16890993
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Digital image elasto-tomography: combinatorial and hybrid optimization algorithms for shape-based elastic property reconstruction.
    Peters A; Chase JG; Van Houten EE
    IEEE Trans Biomed Eng; 2008 Nov; 55(11):2575-83. PubMed ID: 18990627
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Mumford-Shah algorithm applied to videokeratography image processing and consequences to refractive power values.
    Florindo JB; Soares SH; de Carvalho LA; Bruno OM
    Comput Methods Programs Biomed; 2007 Jul; 87(1):61-7. PubMed ID: 17531345
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [A method for extracting landmark geometric data from X-ray images].
    Yan S; Xia Q; Qian L; Wang C
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2008 Oct; 25(5):1039-43. PubMed ID: 19024442
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Development of a video image system for wireless capsule endoscopes based on DSP].
    Yang L; Peng C; Wu H; Zhao D; Zhang J
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2008 Feb; 25(1):7-11. PubMed ID: 18435246
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Precise segmentation of cleavage of the neuron stem cells in time lapse image sequences].
    Tang C; Su X; Cui Y
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2008 Apr; 25(2):439-44. PubMed ID: 18610638
    [TBL] [Abstract][Full Text] [Related]  