These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. Absolute temperature MR imaging with thulium 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetramethyl-1,4,7,10-tetraacetic acid (TmDOTMA-). James JR; Gao Y; Miller MA; Babsky A; Bansal N Magn Reson Med; 2009 Aug; 62(2):550-6. PubMed ID: 19526494 [TBL] [Abstract][Full Text] [Related]
4. Noninvasive thermometry using hyperfine-shifted MR signals from paramagnetic lanthanide complexes. Hekmatyar SK; Kerkhoff RM; Pakin SK; Hopewell P; Bansal N Int J Hyperthermia; 2005 Sep; 21(6):561-74. PubMed ID: 16147440 [TBL] [Abstract][Full Text] [Related]
5. Non-invasive magnetic resonance thermometry using thulium-1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetate (TmDOTA(-)). Hekmatyar SK; Poptani H; Babsky A; Leeper DB; Bansal N Int J Hyperthermia; 2002; 18(3):165-79. PubMed ID: 12028635 [TBL] [Abstract][Full Text] [Related]
6. Non-invasive magnetic resonance thermography during regional hyperthermia. Lüdemann L; Wlodarczyk W; Nadobny J; Weihrauch M; Gellermann J; Wust P Int J Hyperthermia; 2010; 26(3):273-82. PubMed ID: 20345269 [TBL] [Abstract][Full Text] [Related]
7. Validation of fast MR thermometry at 1.5 T with gradient-echo echo planar imaging sequences: phantom and clinical feasibility studies. Cernicanu A; Lepetit-Coiffe M; Roland J; Becker CD; Terraz S NMR Biomed; 2008 Oct; 21(8):849-58. PubMed ID: 18574794 [TBL] [Abstract][Full Text] [Related]
8. Non-invasive ultrasound-based temperature imaging for monitoring radiofrequency heating-phantom results. Daniels MJ; Varghese T; Madsen EL; Zagzebski JA Phys Med Biol; 2007 Aug; 52(16):4827-43. PubMed ID: 17671338 [TBL] [Abstract][Full Text] [Related]
9. Noninvasive monitoring of brain temperature during mild hypothermia. Weis J; Covaciu L; Rubertsson S; Allers M; Lunderquist A; Ahlström H Magn Reson Imaging; 2009 Sep; 27(7):923-32. PubMed ID: 19282122 [TBL] [Abstract][Full Text] [Related]
10. A practical approach to thermography in a hyperthermia/magnetic resonance hybrid system: validation in a heterogeneous phantom. Gellermann J; Wlodarczyk W; Ganter H; Nadobny J; Fähling H; Seebass M; Felix R; Wust P Int J Radiat Oncol Biol Phys; 2005 Jan; 61(1):267-77. PubMed ID: 15629620 [TBL] [Abstract][Full Text] [Related]
11. Analysis of factors important for transurethral ultrasound prostate heating using MR temperature feedback. Chopra R; Wachsmuth J; Burtnyk M; Haider MA; Bronskill MJ Phys Med Biol; 2006 Feb; 51(4):827-44. PubMed ID: 16467581 [TBL] [Abstract][Full Text] [Related]
12. Model-based PRFS thermometry using fat as the internal reference and the extended Prony algorithm for model fitting. Pan X; Li C; Ying K; Weng D; Qin W; Li K Magn Reson Imaging; 2010 Apr; 28(3):418-26. PubMed ID: 20133096 [TBL] [Abstract][Full Text] [Related]
13. A performance analysis of echographic ultrasonic techniques for non-invasive temperature estimation in hyperthermia range using phantoms with scatterers. Bazán I; Vazquez M; Ramos A; Vera A; Leija L Ultrasonics; 2009 Mar; 49(3):358-76. PubMed ID: 19100591 [TBL] [Abstract][Full Text] [Related]
14. An analytic method to predict the thermal map of cryosurgery iceballs in MR images. Fournial R; Traoré AS; Laurendeau D; Moisan C IEEE Trans Med Imaging; 2004 Jan; 23(1):122-9. PubMed ID: 14719693 [TBL] [Abstract][Full Text] [Related]
15. Brain temperature by Biosensor Imaging of Redundant Deviation in Shifts (BIRDS): comparison between TmDOTP5- and TmDOTMA-. Coman D; Trubel HK; Hyder F NMR Biomed; 2010 Apr; 23(3):277-85. PubMed ID: 19957287 [TBL] [Abstract][Full Text] [Related]
16. A clinical water-coated antenna applicator for MR-controlled deep-body hyperthermia: a comparison of calculated and measured 3-D temperature data sets. Nadobny J; Wlodarczyk W; Westhoff L; Gellermann J; Felix R; Wust P IEEE Trans Biomed Eng; 2005 Mar; 52(3):505-19. PubMed ID: 15759581 [TBL] [Abstract][Full Text] [Related]
17. An internal reference model-based PRF temperature mapping method with Cramer-Rao lower bound noise performance analysis. Li C; Pan X; Ying K; Zhang Q; An J; Weng D; Qin W; Li K Magn Reson Med; 2009 Nov; 62(5):1251-60. PubMed ID: 19780176 [TBL] [Abstract][Full Text] [Related]
18. Crushed rephased orthogonal slice selection (CROSS) for simultaneous acquisition of two orthogonal proton resonance frequency temperature maps. Krafft AJ; Rauschenberg J; Maier F; Jenne JW; Bock M J Magn Reson Imaging; 2013 Dec; 38(6):1510-20. PubMed ID: 23677906 [TBL] [Abstract][Full Text] [Related]
19. Noninvasive magnetic resonance thermography of soft tissue sarcomas during regional hyperthermia: correlation with response and direct thermometry. Gellermann J; Hildebrandt B; Issels R; Ganter H; Wlodarczyk W; Budach V; Felix R; Tunn PU; Reichardt P; Wust P Cancer; 2006 Sep; 107(6):1373-82. PubMed ID: 16902986 [TBL] [Abstract][Full Text] [Related]
20. Ultrasound phase-contrast transmission imaging of localized thermal variation and the identification of fat/tissue boundaries. Clement GT; Hynynen K Phys Med Biol; 2005 Apr; 50(7):1585-600. PubMed ID: 15798345 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]