These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

125 related articles for article (PubMed ID: 1640761)

  • 1. Triaxial force transducer for investigating stresses at the stump/socket interface.
    Williams RB; Porter D; Roberts VC; Regan JF
    Med Biol Eng Comput; 1992 Jan; 30(1):89-96. PubMed ID: 1640761
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of computational analysis with clinical measurement of stresses on below-knee residual limb in a prosthetic socket.
    Zhang M; Roberts C
    Med Eng Phys; 2000 Nov; 22(9):607-12. PubMed ID: 11259929
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Conventional patellar-tendon-bearing (PTB) socket/stump interface dynamic pressure distributions recorded during the prosthetic stance phase of gait of a trans-tibial amputee.
    Convery P; Buis AW
    Prosthet Orthot Int; 1998 Dec; 22(3):193-8. PubMed ID: 9881607
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Interface pressures and shear stresses at thirteen socket sites on two persons with transtibial amputation.
    Sanders JE; Lam D; Dralle AJ; Okumura R
    J Rehabil Res Dev; 1997 Jan; 34(1):19-43. PubMed ID: 9021623
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Frictional action at lower limb/prosthetic socket interface.
    Zhang M; Turner-Smith AR; Roberts VC; Tanner A
    Med Eng Phys; 1996 Apr; 18(3):207-14. PubMed ID: 8718946
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Clinical investigation of the pressure and shear stress on the trans-tibial stump with a prosthesis.
    Zhang M; Turner-Smith AR; Tanner A; Roberts VC
    Med Eng Phys; 1998 Apr; 20(3):188-98. PubMed ID: 9690489
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Interface shear stresses during ambulation with a below-knee prosthetic limb.
    Sanders JE; Daly CH; Burgess EM
    J Rehabil Res Dev; 1992; 29(4):1-8. PubMed ID: 1432723
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Development and validation of a 3D-printed interfacial stress sensor for prosthetic applications.
    Laszczak P; Jiang L; Bader DL; Moser D; Zahedi S
    Med Eng Phys; 2015 Jan; 37(1):132-7. PubMed ID: 25455164
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Interface mechanics in external prosthetics: review of interface stress measurement techniques.
    Sanders JE
    Med Biol Eng Comput; 1995 Jul; 33(4):509-16. PubMed ID: 7475380
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effects of alignment changes on stance phase pressures and shear stresses on transtibial amputees: measurements from 13 transducer sites.
    Sanders JE; Bell DM; Okumura RM; Dralle AJ
    IEEE Trans Rehabil Eng; 1998 Mar; 6(1):21-31. PubMed ID: 9535520
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Finite element analysis of the contact interface between trans-femoral stump and prosthetic socket.
    Zhang L; Zhu M; Shen L; Zheng F
    Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():1270-3. PubMed ID: 24109926
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Changes in interface pressure and stump shape over time: preliminary results from a trans-tibial amputee subject.
    Sanders JE; Greve JM; Clinton C; Hafner BJ
    Prosthet Orthot Int; 2000 Aug; 24(2):163-8. PubMed ID: 11061203
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Techniques for Interface Stress Measurements within Prosthetic Sockets of Transtibial Amputees: A Review of the Past 50 Years of Research.
    Al-Fakih EA; Abu Osman NA; Mahmad Adikan FR
    Sensors (Basel); 2016 Jul; 16(7):. PubMed ID: 27447646
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Interface pressures and shear stresses: sagittal plane angular alignment effects in three trans-tibial amputee case studies.
    Sanders JE; Daly CH
    Prosthet Orthot Int; 1999 Apr; 23(1):21-9. PubMed ID: 10355640
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Stump-socket interface pressure as an aid to socket design in prostheses for trans-femoral amputees--a preliminary study.
    Lee VS; Solomonidis SE; Spence WD
    Proc Inst Mech Eng H; 1997; 211(2):167-80. PubMed ID: 9184457
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Socket/stump interface dynamic pressure distributions recorded during the prosthetic stance phase of gait of a trans-tibial amputee wearing a hydrocast socket.
    Convery P; Buis AW
    Prosthet Orthot Int; 1999 Aug; 23(2):107-12. PubMed ID: 10493137
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The capability of fiber Bragg grating sensors to measure amputees' trans-tibial stump/socket interface pressures.
    Al-Fakih EA; Osman NA; Eshraghi A; Adikan FR
    Sensors (Basel); 2013 Aug; 13(8):10348-57. PubMed ID: 23941909
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Clinical measurement of normal and shear stresses on a trans-tibial stump: characteristics of wave-form shapes during walking.
    Sanders JE; Daly CH; Burgess EM
    Prosthet Orthot Int; 1993 Apr; 17(1):38-48. PubMed ID: 8337099
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effects of fluid insert volume changes on socket pressures and shear stresses: case studies from two trans-tibial amputee subjects.
    Sanders JE; Jacobsen AK; Fergason JR
    Prosthet Orthot Int; 2006 Dec; 30(3):257-69. PubMed ID: 17162516
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of computational analysis with clinical measurement of stresses on a below-knee residual limb in a prosthetic socket [Medical Engineering & Physics 22 (2000):607-12].
    Paul JP
    Med Eng Phys; 2001 Sep; 23(7):519-20. PubMed ID: 11686125
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 7.