These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

148 related articles for article (PubMed ID: 16415154)

  • 1. Re: renal artery stent placement: a simple technique to intubate the renal artery in difficult situations.
    Sapra RR; Gupta R; Kachru R; Kaul U
    J Vasc Interv Radiol; 2006 Jan; 17(1):186-7. PubMed ID: 16415154
    [No Abstract]   [Full Text] [Related]  

  • 2. A double-guide-wire technique in renal angioplasty. A modified approach.
    Korogi Y; Takahashi M
    Acta Radiol; 1993 Mar; 34(2):196-7. PubMed ID: 8452730
    [No Abstract]   [Full Text] [Related]  

  • 3. Renal angioplasty and stenting.
    Oliva VL; Soulez G; Therasse E
    Can Assoc Radiol J; 2001 Jun; 52(3):174-82. PubMed ID: 11436412
    [No Abstract]   [Full Text] [Related]  

  • 4. Treatment of reoccurring instent restenosis following reintervention after stent-supported renal artery angioplasty.
    Zeller T; Sixt S; Rastan A; Schwarzwälder U; Müller C; Frank U; Bürgelin K; Schwarz T; Hauswald K; Brantner R; Noory E; Neumann FJ
    Catheter Cardiovasc Interv; 2007 Aug; 70(2):296-300. PubMed ID: 17630674
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Treatment of renovascular hypertension with percutaneous transluminal renal angioplasty].
    Andersen PE; Jacobsen IA; Justesen P
    Ugeskr Laeger; 2001 Aug; 163(33):4393-7. PubMed ID: 11521578
    [No Abstract]   [Full Text] [Related]  

  • 6. Exact deployment of stents in ostial renal artery stenosis using the stent tail wire or Szabo technique.
    Salazar M; Kern MJ; Patel PM
    Catheter Cardiovasc Interv; 2009 Nov; 74(6):946-50. PubMed ID: 19496146
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A dual wire approach to severe ostial bifurcating renal artery stenosis.
    Lorin JD; Hirsh DS; Attubato MJ; Sedlis SP
    Catheter Cardiovasc Interv; 2006 Jun; 67(6):956-60. PubMed ID: 16649236
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Renal artery stent placement: long-term results with the Wallstent endoprosthesis.
    Hennequin LM; Joffre FG; Rousseau HP; Aziza R; Tregant P; Bernadet P; Salvador M; Chamontin B
    Radiology; 1994 Jun; 191(3):713-9. PubMed ID: 8184051
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Novel stent system for accurate placement in aorto-ostial renal artery disease: preclinical study in porcine renal artery model.
    Suzuki Y; Ikeno F; Lyons JK; Koizumi T; Yeung AC
    Cardiovasc Revasc Med; 2007; 8(2):99-102. PubMed ID: 17574168
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Percutaneous removal of a stripped-off Palmaz stent in the renal artery].
    Schmitz-Rode T; Günther RW
    Rofo; 1996 Sep; 165(3):293-5. PubMed ID: 8924692
    [No Abstract]   [Full Text] [Related]  

  • 11. Technical note on renal angioplasty and stenting: new developments that facilitate its performance.
    Silva MB; Bohannon WT; Santana D
    Vascular; 2004 Jan; 12(1):42-50. PubMed ID: 15127854
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Positionally dependent renal artery restenosis.
    Kim ES; Whitelaw S; Bajzer CT; Gornik HL
    Circulation; 2009 Aug; 120(8):714-5. PubMed ID: 19704111
    [No Abstract]   [Full Text] [Related]  

  • 13. Angioplasty through the side of a renal artery stent.
    Robertson IR; Barron D; Kessel D
    J Vasc Interv Radiol; 1998; 9(6):1030-2. PubMed ID: 9840055
    [No Abstract]   [Full Text] [Related]  

  • 14. Renal artery stenosis: preliminary results of treatment with the Strecker stent.
    Kuhn FP; Kutkuhn B; Torsello G; Mödder U
    Radiology; 1991 Aug; 180(2):367-72. PubMed ID: 1829842
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Renal artery angioplasty: techniques and early results.
    Sos TA; Saddekni S; Sniderman KW; Weiner M; Beinart C; Pickering TG; Case DB; Vaughan ED; Laragh JH
    Urol Radiol; 1981-1982; 3(4):223-31. PubMed ID: 6211813
    [No Abstract]   [Full Text] [Related]  

  • 16. Optimal treatment of renal artery in-stent restenosis: repeat stent placement versus angioplasty alone.
    N'Dandu ZM; Badawi RA; White CJ; Grise MA; Reilly JP; Jenkins JS; Collins TJ; Ramee SR
    Catheter Cardiovasc Interv; 2008 Apr; 71(5):701-5. PubMed ID: 18360868
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Renal artery intervention: origins and new technical advances.
    Mahler F; Baumgartner I; Do DD; Triller J
    J Invasive Cardiol; 1999 Feb; 11(2):97-102; discussion 102. PubMed ID: 10745491
    [No Abstract]   [Full Text] [Related]  

  • 18. [Renal stent implantation. The current indications, 2-year results and the possibilities for percutaneous stent recovery].
    Kuhn FP; Malms J; Kutkuhn B; Fürst G; Torsello G; Mödder U
    Rofo; 1992 Jul; 157(1):65-71. PubMed ID: 1386259
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Treatment of ostial renal-artery stenoses with vascular endoprostheses after unsuccessful balloon angioplasty.
    Blum U; Krumme B; Flügel P; Gabelmann A; Lehnert T; Buitrago-Tellez C; Schollmeyer P; Langer M
    N Engl J Med; 1997 Feb; 336(7):459-65. PubMed ID: 9017938
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Angiography and pressure measurement with a coaxial sliding guidewire: follow-up after renal angioplasty].
    Schmitz-Rode T; Günther RW; Keulers P
    Rofo; 1993 Jan; 158(1):74-5. PubMed ID: 8425080
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 8.