These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

601 related articles for article (PubMed ID: 16416409)

  • 1. Image adaptive point-spread function estimation and deconvolution for in vivo confocal microscopy.
    Von Tiedemann M; Fridberger A; Ulfendahl M; Tomo I; Boutet de Monvel J
    Microsc Res Tech; 2006 Jan; 69(1):10-20. PubMed ID: 16416409
    [TBL] [Abstract][Full Text] [Related]  

  • 2. High-definition mapping of neural activity using voltage-sensitive dyes.
    Cinelli AR
    Methods; 2000 Aug; 21(4):349-72. PubMed ID: 10964579
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Image-adaptive deconvolution for three-dimensional deep biological imaging.
    de Monvel JB; Scarfone E; Le Calvez S; Ulfendahl M
    Biophys J; 2003 Dec; 85(6):3991-4001. PubMed ID: 14645088
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Adaptive penalty likelihood for reconstruction of multidimensional confocal microscopy images.
    Zhu D; Razaz M; Lee R
    Comput Med Imaging Graph; 2005 Jul; 29(5):319-31. PubMed ID: 15893912
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A method of PSF generation for 3D brightfield deconvolution.
    Tadrous PJ
    J Microsc; 2010 Feb; 237(2):192-9. PubMed ID: 20096049
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Improvement in volume estimation from confocal sections after image deconvolution.
    Difato F; Mazzone F; Scaglione S; Fato M; Beltrame F; Kubínová L; Janácek J; Ramoino P; Vicidomini G; Diaspro A
    Microsc Res Tech; 2004 Jun; 64(2):151-5. PubMed ID: 15352086
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Shack-Hartmann wave front measurements in cortical tissue for deconvolution of large three-dimensional mosaic transmitted light brightfield micrographs.
    Oberlaender M; Broser PJ; Sakmann B; Hippler S
    J Microsc; 2009 Feb; 233(2):275-89. PubMed ID: 19220694
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Isotropic high-resolution three-dimensional confocal micro-rotation imaging for non-adherent living cells.
    Le Saux B; Chalmond B; Yu Y; Trouvé A; Renaud O; Shorte SL
    J Microsc; 2009 Mar; 233(3):404-16. PubMed ID: 19250461
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Fast 4D Microscopy.
    De Mey JR; Kessler P; Dompierre J; Cordelières FP; Dieterlen A; Vonesch JL; Sibarita JB
    Methods Cell Biol; 2008; 85():83-112. PubMed ID: 18155460
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Image restoration for confocal microscopy: improving the limits of deconvolution, with application to the visualization of the mammalian hearing organ.
    Boutet de Monvel J; Le Calvez S; Ulfendahl M
    Biophys J; 2001 May; 80(5):2455-70. PubMed ID: 11325744
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Deconvolution and chromatic aberration corrections in quantifying colocalization of a transcription factor in three-dimensional cellular space.
    Abraham T; Allan SE; Levings MK
    Micron; 2010 Aug; 41(6):633-40. PubMed ID: 20392647
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Analysis of tubular structures in three-dimensional confocal images.
    Streekstra GJ; van Pelt J
    Network; 2002 Aug; 13(3):381-95. PubMed ID: 12222820
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Automatic noise quantification for confocal fluorescence microscopy images.
    Paul P; Duessmann H; Bernas T; Huber H; Kalamatianos D
    Comput Med Imaging Graph; 2010 Sep; 34(6):426-34. PubMed ID: 20462738
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Richardson-Lucy algorithm with total variation regularization for 3D confocal microscope deconvolution.
    Dey N; Blanc-Feraud L; Zimmer C; Roux P; Kam Z; Olivo-Marin JC; Zerubia J
    Microsc Res Tech; 2006 Apr; 69(4):260-6. PubMed ID: 16586486
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Single-pinhole confocal imaging of sub-resolution sparse objects using experimental point spread function and image restoration.
    Diaspro A; Annunziata S; Robello M
    Microsc Res Tech; 2000 Dec; 51(5):464-8. PubMed ID: 11074617
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Automated three-dimensional tracing of neurons in confocal and brightfield images.
    He W; Hamilton TA; Cohen AR; Holmes TJ; Pace C; Szarowski DH; Turner JN; Roysam B
    Microsc Microanal; 2003 Aug; 9(4):296-310. PubMed ID: 12901764
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Estimating locations of quantum-dot-encoded microparticles from ultra-high density 3-D microarrays.
    Sarder P; Nehorai A
    IEEE Trans Nanobioscience; 2008 Dec; 7(4):284-97. PubMed ID: 19203872
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Simultaneous degradation estimation and restoration of confocal images and performance evaluation by colocalization analysis.
    Rooms F; Philips W; Lidke DS
    J Microsc; 2005 Apr; 218(Pt 1):22-36. PubMed ID: 15817060
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Blind image deconvolution using machine learning for three-dimensional microscopy.
    Kenig T; Kam Z; Feuer A
    IEEE Trans Pattern Anal Mach Intell; 2010 Dec; 32(12):2191-204. PubMed ID: 20975117
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Sensitivity to point-spread function parameters in medical ultrasound image deconvolution.
    Shin HC; Prager R; Ng J; Gomersall H; Kingsbury N; Treece G; Gee A
    Ultrasonics; 2009 Mar; 49(3):344-57. PubMed ID: 19068260
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 31.